Specification: Part Number 1023890 Safe SICK device communication via EFI/SDL: + Maximum output current: 500 mA Number of simultaneously monitored protective fields: ≤ 4 Safety integrity level: SIL2 (IEC 61508), SILCL2 (EN 62061) Integrated configuration memory: + Distance measuring range: 49 m Performance level: PL d (EN ISO 13849) Maximum warning field range: 49 m Scan angle: 190 ° Configuration
Specification: Part Number 1023891 Expanded measured data output (CMS): - Hazardous area protection (horizontal): + Type: Type 3 (IEC 61496) Distance measuring range: 49 m Hazardous area protection (vertical): + Ambient operating temperature: -10 °C ... +50 °C Number of reset-/restart inputs: 1 Type of field set: Dual field sets, Triple field sets Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:
Specification: Part Number 1023892 Access protection (vertical): + Number of multiple samplings: Configurable 2 ... 16 Scan angle: 190 ° Expanded measured data output (CMS): - TM (mission time): 20 a (EN ISO 13849) Number of monitoring cases: 16 Number of dynamic control inputs: 2 External device monitoring (EDM): + Incremental encoder inputs: + Number of application diagnostic outputs: 3 Electri
Specification: Part Number 1023893 Number of EDM inputs: 1 PFHd: 8.0 1E-08 (EN ISO 13849) Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) Performance level: PL d (EN ISO 13849) Ambient operating temperature: -10 °C ... +50 °C Protection class: II (EN 50178) Maximum warning field range: 49 m Number of multiple samplings: Configurable 2 ... 16 Number of static control inputs with EFI: 5
Specification: Part Number 1052109 Number of multiple samplings: Configurable 2 ... 16 Maximum output current: 500 mA Number of monitoring cases: 32 Response time: 60 ms Access protection (vertical): + Scan angle: 190 ° Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) Protection class: II (EN 50178) Dimensions (W x H x D): 155 mm x 185 mm x 160 mm Static protective field switching: +
Specification: Part Number 1052595 Supply voltage: 16.8 V DC, 24 V DC, 28.8 V DC Hazardous area protection (vertical): + Number of monitoring cases: 4 Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) Interfaces for configuration and diagnostics using CDS: TCP port 9000 and UDP port 30718 RS-232 Distance measuring range: 49 m Weight: 3.3 kg Type of field set: Dual field sets PFHd: 8.0 1E-08 (
Specification: Part Number 1045654 Distance measuring range: 49 m Number of field sets: 4 Number of multiple samplings: Configurable 2 ... 16 Performance level: PL d (EN ISO 13849) Port properties: Auto-negotiation Auto-crossover (MDIX) Auto-polarity 100Base-TX Access protection (vertical): + Integrated configuration memory: + Conformance: Conformance Class B Scan angle: 190 ° Hazardous area protection
Specification: Part Number 1052596 Access protection (vertical): + Scan angle: 190 ° Number of simultaneously monitored protective fields: 2 Hazardous area protection (horizontal): + Category: Category 3 (EN ISO 13849) External device monitoring (EDM): - Weight: 3.3 kg Hazardous area protection (vertical): + Number of monitoring cases: 16 Incremental encoder inputs: - Configuration and diagnostics
Specification: Part Number 1045655 Safe SICK device communication via EFI/SDL: - Maximum warning field range: 49 m Number of multiple samplings: Configurable 2 ... 16 Protective field range: 7 m Conformance: Conformance Class B Weight: 3.3 kg Integrated configuration memory: + Resolution: 30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable Supply voltage: 16.8 V DC, 24 V DC, 28.8 V DC Switch properties: F
Specification: Part Number 1026820 Supply voltage: 16.8 V DC, 24 V DC, 30 V DC Number of field sets: 1 Hazardous area protection (horizontal): + Number of safe outputs: 2, Safety outputs (OSSD) Response time: 80 ms Type: Type 3 (IEC 61496) Type of field set: Triple field sets Maximum warning field range: 8 m Category: Category 3 (EN ISO 13849) Enclosure rating: IP 65 (EN 60529) Number of multiple s
Specification: Part Number 1026821 Integrated configuration memory: + Configuration and diagnostics interface: RS-232 Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) Expanded measured data output (CMS): - Number of stand-by inputs: 1 Static protective field switching: + Ambient operating temperature: -10 °C ... +50 °C Type: Type 3 (IEC 61496) Category: Category 3 (EN ISO 13849) Scan ang
Specification: Part Number 1026822 Electrical connection: System plug with or without connecting cable Ambient operating temperature: -10 °C ... +50 °C Number of field sets: 8 Number of EDM inputs: 1 Dimensions (W x H x D): 102 mm x 152 mm x 106 mm PFHd: 8.0 1E-08 (EN ISO 13849) Number of dynamic control inputs: 2 Distance measuring range: 30 m Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:
Specification: Part Number 1050193 Resolution: 30 mm, 40 mm, 50 mm, 70 mm, configurable Number of EDM inputs: 1 Safe SICK device communication via EFI/SDL: + Number of stand-by inputs: 1 Number of multiple samplings: Configurable 2 ... 16 Access protection (vertical): + Data interface: RS-422 Enclosure rating: IP 65 (EN 60529) Response time: 80 ms Integrated configuration memory: + PFHd: 8.0 1E-
Specification: Part Number 1056427 Incremental encoder inputs: - Number of reset-/restart inputs: 1 Hazardous area protection (vertical): + Type: Type 3 (IEC 61496) Integrated configuration memory: + Supply voltage: 16.8 V DC, 24 V DC, 30 V DC Safe SICK device communication via EFI/SDL: + TM (mission time): 20 a (EN ISO 13849) Number of monitoring cases: 1 Static protective field switching: - Dimen
Specification: Part Number 1056428 Maximum warning field range: 8 m Type of field set: Triple field sets Enclosure rating: IP 65 (EN 60529) Measured data output: + Hazardous area protection (vertical): + Number of universal I/Os: 5 Configuration and diagnostics interface: RS-232 Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) Protective field range: 3 m Number of application diagnostic o
Specification: Part Number 1056429 Number of dynamic control inputs: 2 Distance measuring range: 30 m Safe SICK device communication via EFI/SDL: + Type of field set: Triple field sets Number of universal I/Os: 5 Incremental encoder inputs: + Number of monitoring cases: 32 Number of field sets: 8 Electrical connection: System plug with or without connecting cable Performance level: PL d (EN ISO 13849
Specification: Part Number 1057641 PFHd: 8.0 1E-08 (EN ISO 13849) Distance measuring range: 30 m External device monitoring (EDM): + Protection class: III (EN 50178) Dimensions (W x H x D): 102 mm x 152 mm x 106 mm Hazardous area protection (vertical): + Number of monitoring cases: 32 Electrical connection: System plug with or without connecting cable Type: Type 3 (IEC 61496) Supply voltage: 16.8 V DC
Specification: Part Number 1041648 Protection class: II (EN 50178) Maximum output current: 500 mA Resolution: 30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable Number of application diagnostic outputs: 2 Category: Category 3 (EN ISO 13849) Incremental encoder inputs: - Electrical connection: System plug Performance level: PL d (EN ISO 13849) PFHd: 8.0 1E-08 (EN ISO 13849) Hazardous area protection (hor
The S300 mini is the most compact Sick laser scanner available with dimensions of just h116 x w102 x d105mm. This compact size increases the number of applications that laser scanners can be used in. Series of safty laser scanner with very compact design. It has 270° scan angle and 2m protective field range. The main characteristics of S32B-2011BA: Part Number: 1050932; Electrical connection: Cable, 250 mm, with male connector M12, 8
Specification: Part Number 1051884 Number of outputs: Depends on the configuration of the connected EFI device Number of field sets: 16 Resolution: 30 mm, 40 mm, 50 mm, 70 mm, configurable Measured data output: - Weight: 0.8 kg, without connecting cables Safety integrity level: SIL2 (IEC 61508), SILCL2 (EN 62061) Incremental encoder inputs: + Distance measuring range: 30 m Category: Category 3 (EN ISO 1384
Specification: Part Number 1056430 Static protective field switching: - Category: Category 3 (EN ISO 13849) Protective field range: 3 m Distance measuring range: 30 m Laser class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) Response time: 80 ms Enclosure rating: IP 65 (EN 60529) Hazardous area protection (vertical): + Hazardous area protection (horizontal): + Number of safe outputs: 2, Safety ou
Specification: Part Number 1056431 Number of static control inputs with EFI: 5 Protective field range: 3 m Electrical connection: Cable, 250 mm, with male connector M12, 7-pin Safe SICK device communication via EFI/SDL: + Enclosure rating: IP 65 (EN 60529) Supply voltage: 16.8 V DC, 24 V DC, 30 V DC Ambient operating temperature: -10 °C ... +50 °C Type of field set: Triple field sets Scan angle: 270 °
Specification: Part Number 1207475 Aluminum stabilizer: Without stabilizer Enclosure rating: IP 65 Circuit protection: Output Q short-circuit protected Interference suppression VS connections reverse-polarity protected Ripple: < 5 Vpp Task: Switching light grid Protection class: III Working range: 3 m Output load inductive: 1 H EMC: EN 60947-5-2 Switching output: 1 x PNP Configuration: Teach butto
Specification: Part Number 1207711 Number of beams: 8 Technology: Sender/receiver Shock load: 10 g / DIN EN 60068-2-29 / 16 ms Muting function: Muting function inactive EMC: EN 60947-5-2 Weight: 40 g Wave length: IR 950 nm Automatic teach: Automatic teach inactive Initialization time: 1 s Minimum range: Parallel beam: ≥0 mm Supply voltage Vs : DC 24 V, ± 20 % Protection class: III Maxim
Specification: Part Number 1207761 Output load capacitive: 100 nF Muting function: Muting function inactive Output 1: Output 1 active, if light beam interrupted Dimensions (W x H x D): 25 mm x 512.4 mm x 8 mm Synchronization: Optical Initialization time: 1 s Connection type: Short cable with connector M8, 4-pin Inputs: Teach input Vibration resistance: 5 g, 10 Hz ... 55 Hz (IEC 68-2-6) Minimum range: P
Specification: Part Number 1045020 Initialization time: 1 s Output current Imax.: 100 mA Ambient temperature: Operation: -25 ... +55 °C Storage: -25 ... +70 °C Power consumption sender : 112 mA Synchronization: Optical Beam separation: 40 mm Aluminum stabilizer: Without stabilizer Housing material: PMMA Switching frequency: 500 kHz Working range: 3 m Enclosure rating: IP 65 Protection class:
Specification: Part Number 1048058 Automatic teach: Automatic teach inactive Supply voltage Vs : DC 24 V, ± 20 % Response time: Parallel beam 19 ms Beam separation: 40 mm Task: Switching light grid Inputs: Teach input Configuration: Teach button with configuration software Ambient temperature: Operation: -25 ... +55 °C Storage: -25 ... +70 °C Working range: 3 m Maximum range: 4 m Power consumpti
Specification: Part Number 1213486 Minimum range: Multiple scan: ≥0.3 mm Response time: Multiple scan 57 ms Output load inductive: 1 H Wave length: IR 950 nm Weight: 80 g Shock load: 10 g / DIN EN 60068-2-29 / 16 ms Ambient light safety: Direct: ≥100,000 lx, Indirect: ≥150,000 lx Aluminum stabilizer: Without stabilizer Alignment aid: Without alignment aid Connection type: Short cable with co