Specification: Part Number 6038136 Power consumption: < 10 mA Connection type: M20x1,5 Hysteresis: 10 mm Medium: Bulk solids Signal voltage LOW: < 1 V VDE protection class 2: + Signal voltage HIGH: Uv - 3 V Repeatability: ± 5 mm Fill material density: 0.008 g/cm Housing material: Plastic Probe length: 220 mm Particle size: < 10 mm Sensor material: Stainless steel 1.4404 Initializatio
Specification: Part Number 6044868 Process temperature: -20 °C ... 80 °C Ambient temperature operation: -40 °C ... 70 °C Connection type: M20 x 1.5 Power consumption: < 4.2 mA Initialization time: < 3 s Measurement: Switch Ambient storage temperature: -40 °C ... 80 °C Housing material: Plastic ATEX certification: - Tensile strength: ≤ 3,000 N Output current: < 400 mA Inductive load:
Specification: Part Number 6044871 Connection type: M20 x 1.5 VDE protection class 2: + Ambient temperature operation: -40 °C ... 70 °C Repeatability: ≤ 5 mm Output signal: NAMUR signal: 4.5 V DC ... 12 V DC Probe length: 1,000 mm Fill material density: 0.02 g/cm Housing material: Plastic Response time: 500 ms when covered / 1000 ms when uncovered Tensile strength: ≤ 3,000 N ATEX certificati
Specification: Part Number 6044869 Process pressure: -1 bar ... 6 bar Accuracy of sensor element: ± 10 mm Measurement: Switch Output current: > 10 µA; < 3A AC, 1A DC Hysteresis: 10 mm Tensile strength: ≤ 3,000 N ATEX certification: - Initialization time: < 2 s Process connection: G 1 A Enclosure rating: IP 66 / IP 67, IP 66 / IP 68 (0.2 bar) Process temperature: -20 °C ... 80 °C Power c
Specification: Part Number 6040956 Weight sensor: 0.18 kg Storage temperature: -30 °C ... 80 °C Measuring range: 0 bar ... 1.6 bar Protection class III: + Supply voltage: 10 V DC ... 30 V DC CE-conformity: + Dielectric strength: 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) Rated temperature range: 0 °C ... 50 °C Output signal: 4...20 mA Co
Specification: Part Number 6040939 Long-term drift/one-year stability: ≤ ± 0.2 % Of span (at reference conditions) Electrical safety: Short-circuit protection: QA towards M, Protection class: III, Surge protection: According to EN 61000-4-5 (1.5 J) optional for enhanced varient, Reverse polarity protection: L+ towards M Connection type: Cable PUR Dielectric strength: 500 V DC, NEC Class 02 power supply (low voltage and lo
Specification: Part Number 6040942 Dielectric strength: 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) Measuring range: 0 bar ... 0.4 bar Process temperature: -10 °C ... 50 °C Electrical safety: Short-circuit protection: QA towards M, Protection class: III, Surge protection: According to EN 61000-4-5 (1.5 J) optional for enhanced varient, Reverse polarity protect
Specification: Part Number 6040946 Electrical safety: Short-circuit protection: QA towards M, Protection class: III, Surge protection: According to EN 61000-4-5 (1.5 J) optional for enhanced varient, Reverse polarity protection: L+ towards M Protection class III: + Rated temperature range: 0 °C ... 50 °C CE-conformity: EMC directive: 2004/108/EC, EN 61 326-2-3 Process temperature: -10 °C ... 50 °C Connection type:
Specification: Part Number 6040948 Output signal: 4...20 mA Non-linearity: ≤ ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) Protection class III: + Storage temperature: -30 °C ... 80 °C Long-term drift/one-year stability: ≤ ± 0.2 % Of span (at reference conditions) Enclosure rating: IP 68 Supply voltage: 10 V DC ... 30 V DC Electrical safety: Short-circuit protection: QA to
Specification: Part Number 1062791 IO-Link: + Output current: < 100 mA Signal voltage HIGH: Vs - 2 V Max.probe load: 6 Nm GOST approval: + RoHS certificate: + Signal voltage LOW: ≤ 2 V Process connection: G ¾ A, Titanium Inductive load: < 1 H Probe type: Without probe Capacitive load: 100 nF Protection class: III Process pressure: -1 bar ... 10 bar Output signal: 1 PNP transistor
Specification: Part Number 1060172 Resolution: < 2 mm Power consumption: ≤ 100 mA at 24 V DC without output load Temperature drift: < 0.1 mm/K Accuracy of sensor element: ± 5 mm Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 350 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 15 V Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono rod probe / rope probe Upper signa
Specification: Part Number 1062264 Accuracy of sensor element: ± 5 mm Output signal: 1 PNP transistor output (Q1) und 3 PNP / NPN transistor output (Q2...Q4) switchable, 4 mA ... 20 mA, 0 V ... 10 V automatic switching depending on the load. Maximum level change: 500 mm/s Response time: < 400 ms Conductivity: No limitation Supply voltage: 12 V DC ... 30 V DC Process pressure: -1 bar ... 10 bar Power consump
Specification: Part Number 1060307 Temperature drift: < 0.1 mm/K Response time: < 400 ms MTTF: 194.3 a (EN ISO 13849-1) EMC: EN 61326-1:2006, 2004/108/EG EHEDG approval: + UL approval: + Output current: < 100 mA Repeatability: ≤ 2 mm Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 400 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 13,5 V Enclosure rating: IP 67: EN 6
Specification: Part Number 1071094 Medium: Fluids Process pressure: -1 bar ... 10 bar Protection class: III Ambient temperature coaxial cable: -20 °C ... +60 °C GOST approval: + Repeatability: ≤ 2 mm Length coaxial cable: 3.3 m, PVC Output signal: 1 PNP transistor output (Q1) und 3 PNP / NPN transistor output (Q2...Q4) switchable, 4 mA ... 20 mA, 0 V ... 10 V automatic switching depending on the load.
Specification: Part Number 1057093 Medium: Fluids Ambient storage temperature: -40 °C ... +80 °C Probe type: Mono rod probe EMC: EN 61326-1:2006, 2004/108/EG Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono rod probe / rope probe RoHS certificate: + Process connection: ¾" NPT MTTF: 194.3 a (EN ISO 13849-1) Lower signal level: 3.8 mA ... 4 mA CULus certificate: + Enclosure ratin
Specification: Part Number 1062265 Temperature drift: < 0.1 mm/K Output signal: 1 PNP transistor output (Q1) und 3 PNP / NPN transistor output (Q2...Q4) switchable, 4 mA ... 20 mA, 0 V ... 10 V automatic switching depending on the load. EMC: EN 61326-1:2006, 2004/108/EG Probe length: 300 mm Resolution: < 2 mm MTTF: 194.3 a (EN ISO 13849-1) Protection class: III Inductive load: < 1 H Design: Standard
Specification: Part Number 1056287 Single- and continuous shock: EN 60068-2-27 Medium: Fluids Max.probe load: 6 Nm Repeatability: ≤ 2 mm Accuracy of sensor element: ± 5 mm Signal voltage LOW: ≤ 2 V IO-Link: + UL approval: + Housing material: 303 EHEDG approval: + Lower signal level: 3.8 mA ... 4 mA Power consumption: ≤ 75 mA at 24 V DC without output load Housing design: With clos
Specification: Part Number 1058574 EMC: EN 61326-1:2006, 2004/108/EG Power consumption: ≤ 75 mA at 24 V DC without output load Response time: < 400 ms Process temperature: -20 °C ... +150 °C Conductivity: No limitation Capacitive load: 100 nF RoHS certificate: + Accuracy of sensor element: ± 5 mm Repeatability: ≤ 2 mm Signal voltage HIGH: Vs - 2 V Single- and continuous shock: EN 60068-2
Specification: Part Number 1071139 Ambient storage temperature: -40 °C ... +80 °C Response time: < 400 ms Max.probe load: 6 Nm Process temperature: -20 °C ... +180 °C Power consumption: ≤ 75 mA at 24 V DC without output load Ambient temperature coaxial cable: -20 °C ... +60 °C Accuracy of sensor element: ± 5 mm IO-Link: + Length coaxial cable: 3.3 m, FEP Measurement: Switch, Continuous O
Specification: Part Number 1056927 Signal voltage HIGH: Vs - 2 V Enclosure rating: IP 67: EN 60529, IP 69K: EN 40050 Temperature drift: < 0.1 mm/K RoHS certificate: + Wetted parts: 316L (Ra ≤ 0,8 µm), PEEK Medium: Fluids Repeatability: ≤ 2 mm Signal voltage LOW: ≤ 2 V Interference emission: EN 61000-6-4:2007 IO-Link: + Connection type: Round connector M12 x 1, 5-pin 3-A: - Accura
Specification: Part Number 1057094 Process pressure: -1 bar ... 10 bar Supply voltage: 12 V DC ... 30 V DC Wetted parts: 1.4404, PTFE Conductivity: No limitation Lower signal level: 3.8 mA ... 4 mA Probe type: Mono rod probe Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 350 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 15 V Hysteresis: Min. 2 mm, free adjustable Maximum level
Specification: Part Number 1062266 Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 350 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 15 V Housing material: Plastic PBT EMC: EN 61326-1:2006, 2004/108/EG Output signal: 1 PNP transistor output (Q1) und 3 PNP / NPN transistor output (Q2...Q4) switchable, 4 mA ... 20 mA, 0 V ... 10 V automatic switching depending on the load. IO-Link: + Ambient t
Specification: Part Number 1056225 Inactive area at process connector: 25 mm Hysteresis: Min. 2 mm, free adjustable Measurement: Switch, Continuous Signal voltage HIGH: Vs - 2 V Upper signal level: 20 mA ... 20.5 mA Accuracy of sensor element: ± 5 mm Repeatability: ≤ 2 mm Lower signal level: 3.8 mA ... 4 mA EMC: EN 61326-1:2006, 2004/108/EG Conductivity: No limitation Process pressure: -1 bar
Specification: Part Number 1071078 Initialization time: ≤ 5 s Probe type: Mono rod probe Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono rod probe / rope probe Resolution: < 2 mm Ambient storage temperature: -40 °C ... +80 °C Hysteresis: Min. 2 mm, free adjustable Signal voltage LOW: ≤ 2 V IO-Link: + Output current: < 100 mA Maximum level change: 500 mm/s Ambient temper
Specification: Part Number 1071081 Signal voltage LOW: ≤ 2 V Initialization time: ≤ 5 s Measurement: Switch, Continuous Medium: Fluids Ambient storage temperature: -40 °C ... +80 °C Lower signal level: 3.8 mA ... 4 mA Connection type: Round connector M12 x 1, 5-pin Max.probe load: 6 Nm Process temperature: -20 °C ... +100 °C Output current: < 100 mA Ambient temperature coaxial cable: -20
Specification: Part Number 1071085 Protection class: III Max.probe load: 6 Nm Signal voltage LOW: ≤ 2 V Enclosure rating: IP 67: EN 60529 Repeatability: ≤ 2 mm Response time: < 400 ms IO-Link: + Accuracy of sensor element: ± 5 mm Wetted parts: 1.4404, PTFE Measurement: Switch, Continuous EMC: EN 61326-1:2006, 2004/108/EG Output current: < 100 mA Process pressure: -1 bar ... 10 bar
Specification: Part Number 1071088 IO-Link: + Lower signal level: 3.8 mA ... 4 mA Probe length: 500 mm Repeatability: ≤ 2 mm Length coaxial cable: PVC Ambient temperature coaxial cable: -20 °C ... +60 °C Supply voltage: 12 V DC ... 30 V DC Maximum level change: 500 mm/s Signal voltage LOW: ≤ 2 V Conductivity: No limitation Design: Remote amplifier, cable length 1 m Wetted parts: 1.4404
Specification: Part Number 1071091 Signal voltage LOW: ≤ 2 V Capacitive load: 100 nF Accuracy of sensor element: ± 5 mm Repeatability: ≤ 2 mm Design: Remote amplifier, cable length 2 m Protection class: III Response time: < 400 ms Inductive load: < 1 H Output current: < 100 mA Maximum level change: 500 mm/s Output signal: 1 PNP transistor output (Q1) und 3 PNP / NPN transistor output (Q2
Specification: Part Number 1071095 Protection class: III Enclosure rating: IP 67: EN 60529 MTTF: 194.3 a (EN ISO 13849-1) Repeatability: ≤ 2 mm Response time: < 400 ms Power consumption: ≤ 100 mA at 24 V DC without output load Connection type: Round connector M12 x 1, 8-pin Signal voltage LOW: ≤ 2 V Inductive load: < 1 H Probe type: Mono rod probe Max.probe load: 6 Nm Initialization t