Specification: Part Number 1057094 Process pressure: -1 bar ... 10 bar Supply voltage: 12 V DC ... 30 V DC Wetted parts: 1.4404, PTFE Conductivity: No limitation Lower signal level: 3.8 mA ... 4 mA Probe type: Mono rod probe Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 350 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 15 V Hysteresis: Min. 2 mm, free adjustable Maximum level change: 500 mm/s Inactive area at probe end: 10 mm Connection type: Round connector M12 x 1, 5-pin Ambient temperature operation: -20 °C ... +60 °C GOST approval: + Repeatability: ≤ 2 mm MTTF: 194.3 a (EN ISO 13849-1) Output current: < 100 mA Housing material: Plastic PBT Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono rod probe / rope probe Protection class: III RoHS certificate: + Inductive load: < 1 H Accuracy of sensor element: ± 5 mm Output signal: 1 PNP transistor output (Q1) and 1 PNP / NPN transistor output (Q2) switchable, 4 mA ... 20 mA, 0 V ... 10 V automatic switching depending on the load. Measurement: Switch, Continuous Process temperature: -20 °C ... +100 °C Enclosure rating: IP 67: EN 60529 Process connection: ¾" NPT Inactive area at process connector: 25 mm Design: Standard Capacitive load: 100 nF Medium: Fluids Resolution: < 2 mm Max.probe load: 6 Nm Initialization time: ≤ 5 s Upper signal level: 20 mA ... 20.5 mA EMC: EN 61326-1:2006, 2004/108/EG IO-Link: + Temperature drift: < 0.1 mm/K Power consumption: ≤ 100 mA at 24 V DC without output load Ambient storage temperature: -40 °C ... +80 °C Signal voltage LOW: ≤ 2 V Response time: < 400 ms CULus certificate: + Probe length: 400 mm Signal voltage HIGH: Vs - 2 V