Specification: Part Number 1071078 Initialization time: ≤ 5 s Probe type: Mono rod probe Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono rod probe / rope probe Resolution: < 2 mm Ambient storage temperature: -40 °C ... +80 °C Hysteresis: Min. 2 mm, free adjustable Signal voltage LOW: ≤ 2 V IO-Link: + Output current: < 100 mA Maximum level change: 500 mm/s Ambient temperature coaxial cable: -20 °C ... +60 °C Supply voltage: 12 V DC ... 30 V DC CULus certificate: + RoHS certificate: + Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 350 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 15 V Output signal: 1 PNP transistor output (Q1) and 1 PNP / NPN transistor output (Q2) switchable, 4 mA ... 20 mA, 0 V ... 10 V automatic switching depending on the load. Ambient temperature operation: -20 °C ... +60 °C Inactive area at probe end: 10 mm Response time: < 400 ms MTTF: 194.3 a (EN ISO 13849-1) Process connection: G ¾ A Conductivity: No limitation Process temperature: -20 °C ... +100 °C GOST approval: + Design: Remote amplifier, cable length 1 m Housing material: Plastic PBT Upper signal level: 20 mA ... 20.5 mA Temperature drift: < 0.1 mm/K Length coaxial cable: 1 m, PVC Protection class: III Max.probe load: 6 Nm Process pressure: -1 bar ... 10 bar Repeatability: ≤ 2 mm Measurement: Switch, Continuous Probe length: 500 mm EMC: EN 61326-1:2006, 2004/108/EG Wetted parts: 1.4404, PTFE Lower signal level: 3.8 mA ... 4 mA Enclosure rating: IP 67: EN 60529 Connection type: Round connector M12 x 1, 5-pin Capacitive load: 100 nF Medium: Fluids Power consumption: ≤ 100 mA at 24 V DC without output load Accuracy of sensor element: ± 5 mm Inductive load: < 1 H Signal voltage HIGH: Vs - 2 V Inactive area at process connector: 25 mm