Specification: Part Number 1071085 Protection class: III Max.probe load: 6 Nm Signal voltage LOW: ≤ 2 V Enclosure rating: IP 67: EN 60529 Repeatability: ≤ 2 mm Response time: < 400 ms IO-Link: + Accuracy of sensor element: ± 5 mm Wetted parts: 1.4404, PTFE Measurement: Switch, Continuous EMC: EN 61326-1:2006, 2004/108/EG Output current: < 100 mA Process pressure: -1 bar ... 10 bar Probe type: Mono rod probe Supply voltage: 12 V DC ... 30 V DC MTTF: 194.3 a (EN ISO 13849-1) Probe length: 500 mm Output signal: 1 PNP transistor output (Q1) and 1 PNP / NPN transistor output (Q2) switchable, 4 mA ... 20 mA, 0 V ... 10 V automatic switching depending on the load. Ambient storage temperature: -40 °C ... +80 °C Inductive load: < 1 H Hysteresis: Min. 2 mm, free adjustable Design: Remote amplifier, cable length 3 m Length coaxial cable: 3.3 m, PVC Upper signal level: 20 mA ... 20.5 mA Connection type: Round connector M12 x 1, 5-pin Medium: Fluids Temperature drift: < 0.1 mm/K Process temperature: -20 °C ... +100 °C Conductivity: No limitation Lower signal level: 3.8 mA ... 4 mA CULus certificate: + Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono rod probe / rope probe Capacitive load: 100 nF Signal voltage HIGH: Vs - 2 V Ambient temperature operation: -20 °C ... +60 °C Power consumption: ≤ 100 mA at 24 V DC without output load Maximum level change: 500 mm/s Inactive area at process connector: 25 mm Initialization time: ≤ 5 s Ambient temperature coaxial cable: -20 °C ... +60 °C GOST approval: + RoHS certificate: + Housing material: Plastic PBT Process connection: G ¾ A Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 350 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 15 V Resolution: < 2 mm Inactive area at probe end: 10 mm