Specification: Part Number 6040948 Output signal: 4...20 mA Non-linearity: ≤ ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) Protection class III: + Storage temperature: -30 °C ... 80 °C Long-term drift/one-year stability: ≤ ± 0.2 % Of span (at reference conditions) Enclosure rating: IP 68 Supply voltage: 10 V DC ... 30 V DC Electrical safety: Short-circuit protection: QA towards M, Protection class: III, Surge protection: According to EN 61000-4-5 (1.5 J) optional for enhanced varient, Reverse polarity protection: L+ towards M Pressure type: Gauge pressure Wetted parts: Pressure connection/ diaphragm: Stainless steel, Housing: Stainless steel, Protection cap: PA Weight sensor: 0.18 kg Weight cable: 0.08 kg/m CE-conformity: EMC directive: 2004/108/EC, EN 61 326-2-3 Dielectric strength: 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) Process temperature: -10 °C ... 50 °C Connection type: Cable PUR Temperature coefficient in rated temperature range: Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.2 % of span / 10 K ( < 0.4 % for pressure ranges ≤ 0.25 bar) Measuring range: 0 bar ... 0.6 bar Rated temperature range: 0 °C ... 50 °C CE-conformity: + Non-repeatability: ≤ ± 0.1 % of span Accuracy: