SICK - Safety light curtains

Image
Part Number
Description
Specification: Part Number 1207958 Configuration method: Hard wired Synchronization: Optical, without separate synchronization Storage temperature: -25 °C ... +70 °C Protective field height: 1,080 mm Resolution: 24 mm Weight: 380 g Scanning range: 0 m ... 6 m Power consumption: ≤ 3 A Shock resistance: 10 g, 16 ms (EN 60068-2-27) Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Air humidity:
Specification: Part Number 1207844 Resolution: 24 mm Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Beam coding: + Storage temperature: -25 °C ... +70 °C Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Maximum demand rate: 34 /min (EN ISO 13849)
Specification: Part Number 1207901 TM (mission time): 20 a (EN ISO 13849) Ripple: ≤ 10 % Restart interlock (delivery status): Deactivated Response time: ≤ 13 ms Storage temperature: -25 °C ... +70 °C Enclosure rating: IP 65 (EN 60529) Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Switching current: 300 mA Ambient operating temperature: -20 °C ... +55 °C
Specification: Part Number 1207977 Connection type: Male connector M12, 5-pin PFHd: Standalone system: 2.4  1E-08 (EN ISO 13849) Synchronization: Optical, without separate synchronization Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET External device monitoring (delivery status): Deactivated Resolution: 34 mm Cable length: 700 mm Maximum demand
Specification: Part Number 1207920 Cascaded: + Typical range: 0 m ... 8 m Permitted cable length: ≤ 20 m Switching voltage LOW: 2 V DC Cable length: 700 mm Housing cross-section (incl. system connection): 15 mm x 32 mm Power consumption: ≤ 3 A Restart interlock (delivery status): Deactivated Automatic beam coding: + Type: Type 2 (IEC 61496) Protection class: III (EN 61140) Protective fie
Specification: Part Number 1207940 Air humidity: 15 % ... 95 %, non-condensing Cable length: 700 mm Weight: 400 g Protective field height: 1,140 mm Restart interlock (delivery status): Deactivated Response time: ≤ 17 ms Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Type: Type 2 (IEC 61496) Safe SICK device communication via EFI/SDL: - Cascaded: - Connection type: Male connector M12, 5
Specification: Part Number 1207820 Shock resistance: 10 g, 16 ms (EN 60068-2-27) Connection type: Male connector M12, 5-pin Resolution: 14 mm Storage temperature: -25 °C ... +70 °C Cable length: 700 mm Switching voltage LOW: 2 V DC Maximum demand rate: 34 /min (EN ISO 13849) Ripple: ≤ 10 % Beam coding: + Housing material: Aluminum alloy ALMGSI 0.5 Permitted cable length: ≤ 20 m Type o
Specification: Part Number 1207883 Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Housing material: Aluminum alloy ALMGSI 0.5 Type: Type 2 (IEC 61496) Ambient operating temperature: -20 °C ... +55 °C Enclosure rating: IP 65 (EN 60529) Scanning range: 0 m ... 6 m Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Performance level: PL c (EN ISO 13849), Pay attention
Specification: Part Number 1207959 Restart interlock: + Beam coding: + Ambient operating temperature: -20 °C ... +55 °C Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Enclosure rating: IP 65 (EN 60529) Switching voltage LOW: 2 V DC Maximum demand rate: 34 /min (EN ISO 13849) Connectio
Specification: Part Number 1207845 External device monitoring (delivery status): Deactivated Enclosure rating: IP 65 (EN 60529) Response time: ≤ 13 ms Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Safe SICK device communication via EFI/SDL: - Switching current: 300 mA Configuration method: Hard wired Display elements: LEDs Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Power consumpt
Specification: Part Number 1207902 Test rate (internal test): 47 /s Connection type extension connection: Female connector M12, 5-pin Display elements: LEDs Air humidity: 15 % ... 95 %, non-condensing External device monitoring (EDM): + Safe SICK device communication via EFI/SDL: - External device monitoring (delivery status): Deactivated Automatic beam coding: + Switching current: 300 mA Switching volt
Specification: Part Number 1207978 Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Switching voltage LOW: 2 V DC Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Shock resistance: 10 g, 16 ms (EN 60068-2-27) Test rate (internal test): 58 /s Power consumption: ≤ 3 A Housing cross
Specification: Part Number 1207921 Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) TM (mission time): 20 a (EN ISO 13849) Synchronization: Optical, without separate synchronization Cable length: 700 mm Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Permitted cable length: ≤ 20 m Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics!
Specification: Part Number 1207960 Cascaded: - External device monitoring (EDM): + TM (mission time): 20 a (EN ISO 13849) Restart interlock: + Response time: ≤ 13 ms Switching current: 300 mA Weight: 420 g Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Protective field height: 1,200 mm Switching voltage LOW: 2 V DC Ripple: ≤ 10 % Power consumption: ≤ 3 A Typical range: 0 m ..