Specification: Part Number 1054687 Resistance to vibration: 30 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Error limits: ± 0.05 ° Shaft diameter: 10 mm Measuring step: 0.01 ° Repeat accuracy: 0.002 ° Operating voltage range: 4.5 V DC ... 32 V DC SET (electronic adjustment): H-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) Enclosure rating: IP 65 (according to IEC 60529), housing side, IP 65 (acco
Specification: Part Number 1050966 Storage temperature range: -40 °C ... 100 °C, without package Max. angular acceleration: 500,000 rad/s² Power consumption: 0.5 W (without load) Moment of inertia of the rotor: 40 gcm² Mechanical interface: Through hollow shaft Maximum operating speed: 9,000 /min EMC: (according to EN 61000-6-2 and EN 61000-6-3) SET (electronic adjustment): H-active (L &;8801; 0 - 1,5 V,
Specification: Part Number 1051096 Electrical interface: Connector M12, 8-pin, radial Shaft diameter: 10 mm Power consumption: 0.5 W (without load) Max. number of steps per revolution: 32,768 Interface signals: Clock +, Clock -, Data +, Data- Mechanical interface: Through hollow shaft Enclosure rating: IP 65 (according to IEC 60529), housing side, IP 65 (according to IEC 60529), shaft side Resolution power: 3
Specification: Part Number 1051104 Shaft diameter: 10 mm Measuring step deviation: ± 0.01 ° Repeat accuracy: 0.002 ° Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 mm Electrical interface: Cable, 8-pin, universal, 3 m Interface signals: Clock +, Clock -, Data +, Data- Resistance to shocks: 70 g (according to EN 60068-2-27) Resolution: 15 bit x 12 bit Initialization time: 50 ms Operati
Specification: Part Number 1051106 MTTFd: mean time to dangerous failure: 250 a (EN ISO 13849-1) SET (electronic adjustment): H-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) CW/CCW (counting sequence when turning): L-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) Resolution: 15 bit x 12 bit Working temperature range: -30 °C ... 100 °C Resistance to vibration: 30 g, 10 Hz ... 2,000 Hz (according to EN 60068
Specification: Part Number 1061940 SET (electronic adjustment): H-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) Repeat accuracy: 0.002 ° EMC: (according to EN 61000-6-2 and EN 61000-6-3) Working temperature range: -30 °C ... 100 °C Measuring step: 0.01 ° Resolution power: 4,096 x 4,096 Initialization time: 50 ms Mechanical interface: Through hollow shaft Error limits: ± 0.05 ° Max. angular
Specification: Part Number 1053898 Resolution power: 8,192 x 4,096 CW/CCW (counting sequence when turning): L-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) Max. angular acceleration: 500,000 rad/s² SET (electronic adjustment): H-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) Enclosure rating: IP 65 (according to IEC 60529), housing side, IP 65 (according to IEC 60529), shaft side Moment of inertia of the rot
Specification: Part Number 1052838 Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Operating torque: 0.6 Ncm (20 °C) Clock frequency: 2 MHz Measuring step: 90 ° elektrisch / Strichzahl Bearing lifetime: 3.0 x 10^9 revolutions Operating voltage range: 4.5 V DC ... 32 V DC EMC: (according to EN 61000-6-2 and EN 61000-6-3) Measuring step deviation: ± 0.01 ° Mass:
Specification: Part Number 1050974 EMC: (according to EN 61000-6-2 and EN 61000-6-3) Enclosure rating: IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing side MTTFd: mean time to dangerous failure: 250 a (EN ISO 13849-1) Connection type: Cable, 8-wire, universal, 1.5 m Working temperature range: 0 °C ... +85 °C Resistance to shocks: 50 g, 6 ms (according to EN 60068-2-27) Clock
Specification: Part Number AFM60E-BDLA004096 Electrical interface: SSI/Gray + Incremental, HTL Error limits: ± 0.3 ° Working temperature range: 0 °C ... +85 °C Maximum operating speed: 6,000 /min Max. number of revolutions: 4,096 Measuring step: 90 ° elektrisch / Strichzahl Shaft diameter: 10 mm CW/CCW (counting sequence when turning): L-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) Storage temp
Specification: Part Number 1055698 Power consumption: 0.5 W (without load) Working temperature range: 0 °C ... +85 °C Measuring step: 0.09 ° 360 ° / number of steps EMC: (according to EN 61000-6-2 and EN 61000-6-3) Shaft diameter: 15 mm Error limits: ± 0.3 ° Max. angular acceleration: 500,000 rad/s² Measuring step deviation: ± 0.2 ° Start up torque: 0.8 Ncm (+20 °C) Mechanical interface: Bli
Specification: Part Number 1037650 Max. number of steps per revolution: 4,096 Working temperature range: 0 °C ... +85 °C Resolution power: 4,096 x 4,096 Operating voltage range: 4.5 V DC ... 32 V DC Shaft diameter: 6 mm Clock frequency: 1 MHz Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Permissible relative humidity: 90 % (condensation of the optical scanning not permitted)
Specification: Part Number 1037651 EMC: (according to EN 61000-6-2 and EN 61000-6-3) Mechanical interface: Solid shaft, Servo flange SET (electronic adjustment): H-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) Shaft diameter: 6 mm Resolution: 12 bit x 12 bit Interface signals: Clock +, Clock -, Data +, Data- Resolution power: 4,096 x 4,096 MTTFd: mean time to dangerous failure: 250 a (EN ISO 13849-1)
Specification: Part Number 1054309 Resolution: 8 bit x 12 bit Mass: 0.26 kg Working temperature range: 0 °C ... +85 °C Measuring step deviation: ± 0.2 ° Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Moment of inertia of the rotor: 6.2 gcm² Reverse polarity protection: 1 MTTFd: mean time to dangerous failure: 250 a (EN ISO 13849-1) CW/CCW (counting sequence wh
Specification: Part Number 1066855 Storage temperature range: -40 °C ... +100 °C, without package Max. angular acceleration: 500,000 rad/s² Max. number of revolutions: 4,096 Resolution power: 2,048 x 4,096 Connection type: Cable, 8-wire, universal, 1.5 m Electrical interface: SSI/Gray Maximum operating speed: 9,000 /min Reverse polarity protection: 1 Start up torque: 0.5 Ncm (+20 °C) Enclosure rat
Specification: Part Number 1058545 Maximum operating speed: 9,000 /min Resolution power: 4,096 x 4,096 Clock frequency: 1 MHz Mechanical interface: Solid shaft with flat, Face mount flange Error limits: ± 0.2 ° Working temperature range: 0 °C ... +85 °C Max. number of revolutions: 4,096 Measuring step: 0.09 ° 360 ° / number of steps Max. angular acceleration: 500,000 rad/s² Resolution: 12 bit
Specification: Part Number 1057332 Permissible Load capacity of shaft: 40 N (axial), 80 N (radial) Measuring step: 90 ° elektrisch / Strichzahl Resistance to shocks: 50 g, 6 ms (according to EN 60068-2-27) Load current max.: 30 mA Electrical interface: SSI/Gray + Incremental, HTL Maximum output frequency: 300 kHz Interface signals: A, B: digital differential, Clock +, Clock -, Data +, Data- Mechanical interfa
Specification: Part Number 1051351 Maximum operating speed: 9,000 /min Storage temperature range: -40 °C ... +100 °C, without package Operating voltage range: 4.5 V DC ... 32 V DC Bearing lifetime: 3.0 x 10^9 revolutions Interface signals: Clock +, Clock -, Data +, Data- Resolution power: 4,096 x 4,096 Max. number of steps per revolution: 4,096 Reverse polarity protection: 1 Resistance to vibration: 20
Specification: Part Number 1053304 Resistance to shocks: 50 g, 6 ms (according to EN 60068-2-27) Working temperature range: 0 °C ... +85 °C MTTFd: mean time to dangerous failure: 250 a (EN ISO 13849-1) Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm Electrical interface: SSI/Gray Operating torque: 0.6 Ncm (+20 °C) Maximum operating speed: 9,000 /min Resolution power: 4,096 x 4,096 Code
Specification: Part Number 1055028 Clock frequency: 1 MHz Moment of inertia of the rotor: 40 gcm² Repeat accuracy: 0.002 ° Measuring step deviation: ± 0.2 ° Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Operating voltage range: 4.5 V DC ... 32 V DC Maximum output frequency: 200 kHz Maximum operating speed: 9,000 /min Enclosure rating: IP 65 (according to IEC
Specification: Part Number 1054600 Resistance to shocks: 50 g, 6 ms (according to EN 60068-2-27) Working temperature range: 0 °C ... +85 °C Mechanical interface: Through hollow shaft Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Connection type: Connector M23, 12-pin, radial Electrical interface: SSI/Gray + Incremental, HTL Resolution power: 4,096 x 4,096 EMC: (acc
Specification: Part Number AFM60E-TGAA004096 Start up torque: 0.8 Ncm (+20 °C) Resolution: 12 bit x 12 bit Power consumption: 0.5 W (without load) MTTFd: mean time to dangerous failure: 250 a (EN ISO 13849-1) Code type: Gray Max. number of steps per revolution: 4,096 Electrical interface: SSI/Gray Mechanical interface: Through hollow shaft Moment of inertia of the rotor: 40 gcm² Maximum operating spe
Specification: Part Number AFM60E-TGLA004096 Connection type: Connector M23, 12-pin, radial Operating voltage range: 4.5 V DC ... 32 V DC Shaft diameter: 14 mm Max. number of revolutions: 4,096 Reverse polarity protection: 1 Code sequence: CW/CCW, parameter adjustable Electrical interface: SSI/Gray + Incremental, HTL Reference signal, position: 90 °, electronically, gated with A and B Mechanical interface
Specification: Part Number 1054193 Measuring step deviation: ± 0.2 ° EMC: (according to EN 61000-6-2 and EN 61000-6-3) Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm Max. number of revolutions: 4,096 Maximum operating speed: 9,000 /min Connection type: Cable, 8-wire, universal, 1.5 m Resistance to shocks: 50 g, 6 ms (according to EN 60068-2-27) Interface signals: Clock +, Clock -, Data +
Specification: Part Number 1053128 Resolution power: 4,096 x 4,096 Max. angular acceleration: 500,000 rad/s² Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm Clock frequency: 1 MHz CW/CCW (counting sequence when turning): L-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) Measuring step: 0.09 ° 360 ° / number of steps Initialization time: 50 ms EMC: (according to EN 61000-6-2 and EN 6100
Specification: Part Number 1065327 Start up torque: 0.8 Ncm (+20 °C) Interface signals: A, B: digital differential, Clock +, Clock -, Data +, Data- EMC: (according to EN 61000-6-2 and EN 61000-6-3) Code sequence: CW/CCW, parameter adjustable Mass: 0.2 kg Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 mm Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Moment of inert