Specification: Part Number 1207962 Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Power consumption: ≤ 3 A Synchronization: Optical, without separate synchronization Protective field height: 180 mm Automatic beam coding: + Shock resistance: 10 g, 16 ms (EN 60068-2-27) Maximum demand rate: 34 /min (EN ISO 13849) Permitted cable length: ≤ 20 m Category: Category 2 (EN ISO 13849) Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Enclosure rating: IP 65 (EN 60529) Air humidity: 15 % ... 95 %, non-condensing Restart interlock (delivery status): Deactivated Safe state in the event of a fault: At least one OSSD is in the OFF state. Ripple: ≤ 10 % Restart interlock: + Scanning range: 0 m ... 6 m Storage temperature: -25 °C ... +70 °C Cable length: 160 mm TM (mission time): 20 a (EN ISO 13849) Housing cross-section (incl. system connection): 15 mm x 32 mm Housing material: Aluminum alloy ALMGSI 0.5 Conductor cross-section: 0.34 mm² Display elements: LEDs External device monitoring (delivery status): Deactivated Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Weight: 75 g Resolution: 34 mm Typical range: 0 m ... 8 m Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Type: Type 2 (IEC 61496) External device monitoring (EDM): + Cascaded: - Protection class: III (EN 61140) Ambient operating temperature: -20 °C ... +55 °C PFHd: Standalone system: 2.4 1E-08 (EN ISO 13849) Test rate (internal test): 58 /s Switching voltage LOW: 2 V DC Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Configuration method: Hard wired Beam coding: + Safe SICK device communication via EFI/SDL: - Connection type: Male connector M12, 5-pin Switching current: 300 mA Response time: ≤ 13 ms