Specification: Part Number 1207885 Power consumption: ≤ 3 A External device monitoring (EDM): + Air humidity: 15 % ... 95 %, non-condensing Configuration method: Hard wired Cascaded: + Category: Category 2 (EN ISO 13849) Response time: ≤ 13 ms Cable length: 160 mm Housing cross-section (incl. system connection): 15 mm x 32 mm Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Display elements: LEDs Shock resistance: 10 g, 16 ms (EN 60068-2-27) Restart interlock: + External device monitoring (delivery status): Deactivated Switching voltage LOW: 2 V DC Connection type extension connection: Female connector M12, 5-pin Restart interlock (delivery status): Deactivated Maximum demand rate: 28 /min (EN ISO 13849) Switching current: 300 mA Protective field height: 120 mm Enclosure rating: IP 65 (EN 60529) Ripple: ≤ 10 % Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Safe SICK device communication via EFI/SDL: - Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Scanning range: 0 m ... 6 m Weight: 50 g PFHd: Cascaded systems: 5.2 1E-08 (EN ISO 13849) Housing material: Aluminum alloy ALMGSI 0.5 Storage temperature: -25 °C ... +70 °C Safe state in the event of a fault: At least one OSSD is in the OFF state. Beam coding: + Ambient operating temperature: -20 °C ... +55 °C Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Resolution: 24 mm Synchronization: Optical, without separate synchronization Automatic beam coding: + Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Conductor cross-section: 0.34 mm² Protection class: III (EN 61140) Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) TM (mission time): 20 a (EN ISO 13849) Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Type: Type 2 (IEC 61496) Connection type: Male connector M12, 5-pin Permitted cable length: ≤ 20 m Typical range: 0 m ... 8 m Test rate (internal test): 47 /s