SICK

Image
Part Number
Description
Specification: Part Number 1027831 Ripple: ≤ 5 Vpp Additional function: Customer specific scaled measuring range, Plug & Play, Switching output to monitor the measuring range Typ. light spot size (distance): 15 mm x 15 mm (at 1 m) Weight: 135 g Temperature drift: 0.25 mm/K Protection class: II Shock resistance: EN 60068-2-27 Connection type: Male connector, M12, 5-pin Analog output: 1 x 4 mA ... 20 mA
Specification: Part Number 1028720 Response time : 10 ms / 15 ms Protection class: II Typ. light spot size (distance): 15 mm x 15 mm (at 1 m) Supply voltage Vs : DC 10 V ... 30 V Enclosure rating: IP 65 Housing material: Metal housing with PMMA lens Initialization time: ≤ 250 ms Resolution : 1 mm / 2 mm Weight: 135 g Vibration resistance: EN 60068-2-6 / EN 60068-2-64 Additional function: Custome
Specification: Part Number 1028721 Light source: LED, infrared Initialization time: ≤ 250 ms Weight: 135 g Ambient temperature: Operation: -25 ... +55 °C, Storage: -40 ... +75 °C Protection class: II Laser service life (MTTF at 25 °C): 100,000 h Response time : 10 ms / 15 ms Housing material: Metal housing with PMMA lens Output time: 1 ms Vibration resistance: EN 60068-2-6 / EN 60068-2-64 Addi
Specification: Part Number 1028724 Typ. light spot size (distance): 15 mm x 15 mm (at 1 m) Ripple: ≤ 5 Vpp Laser service life (MTTF at 25 °C): 100,000 h Initialization time: ≤ 250 ms Light source: LED, infrared Shock resistance: EN 60068-2-27 Resolution : 1 mm / 2 mm Response time : 10 ms / 15 ms Additional function: Customer specific scaled measuring range, Plug & Play, Switching output to monitor
Specification: Part Number 1028723 Vibration resistance: EN 60068-2-6 / EN 60068-2-64 Additional function: Customer specific scaled measuring range, Plug & Play, Switching output to monitor the measuring range Initialization time: ≤ 250 ms Temperature drift: 0.25 mm/K Measuring range: 250 mm ... 600 mm, 18 % ... 90 % remission Warm-up time: ≤ 30 min Resolution : 1 mm / 2 mm Housing material: Metal housi
Specification: Part Number 1028722 Resolution : 1 mm / 2 mm Ambient temperature: Operation: -25 ... +55 °C, Storage: -40 ... +75 °C Temperature drift: 0.25 mm/K Ripple: ≤ 5 Vpp Vibration resistance: EN 60068-2-6 / EN 60068-2-64 Protection class: II Laser service life (MTTF at 25 °C): 100,000 h Analog output: 1 x 4 mA ... 20 mA (≤ 300 &;937;) Housing material: Metal housing with PMMA lens Weigh
Specification: Part Number 1026517 Resolution: ≤ 1 mm Electromagnetic compatibility (EMC): EN 61000-6-2, EN 55011 / EN 60947-5-7: 2003-9 Data output: 20,000 CR LF in mm Data interface: RS-422 Measuring range: 0.2 m ... 18 m, 6 % remission 0.2 m ... 30 m, 90 % remision Connection type: Male connector, M12, 5-pin Protection class : II Typ. light spot size (distance): 10 mm (at 7 m) 100 mm (at 70 m) 45 mm (at
Specification: Part Number 1040468 Power consumption: Typ. 3 W Measuring range: 0.2 m ... 18 m, 6 % remission 0.2 m ... 30 m, 90 % remision Temperature drift: Typ. 0.05 mm/K Laser class: 2 (EN 60825/21 CFR 1.040) Light source : Laser, red Supply voltage Vs: DC 10 V ... 30 V, reverse polarity protected, U s ≥ DC 24 V for devices with heating Enclosure rating: IP 65 Ambient temperature: Operation: -10 ... +5
Specification: Part Number 1040472 Light source : Laser, red Weight: 1,000 g Ripple : 5 Vpp Resolution CAN: 0.1 mm Protection class : II Resolution: ≤ 0.1 mm Laser off input: > 12 V Data interface: CAN (Layer 2) Connection type: Male connector, M12, 8-pin Initialization time: 500 ms Ambient temperature: Operation: -10 ... +50 °C Operation with cooling case: -10 ... +75 °C Storage: -25 ... +75
Specification: Part Number 1041095 Maximum range: 3 m Switching output: 2 x NPN (Q and /Q) Task: Switching light grid Shock load: 10 g / DIN EN 60068-2-29 / 16 ms Minimum detectable object (MDO): Parallel beam: ≥ 35 mm ... 65 mm Front screen: PMMA Housing material: Aluminum Protection class: III Circuit protection: Output Q short-circuit protected Interference suppression VS connections reverse-polarity
Specification: Part Number 1042302 Dimensions (W x H x D): 34 mm x 406 mm x 29 mm Detection height: 330 mm Synchronization: Optical Ambient temperature: Operation: -25 ... +55 °C Storage: -40 ... +70 °C Minimum range: &ge;0 mm Power consumption receiver : < 100 mA Evaluation beams: Parallel beam Task: Switching light grid Supply voltage Vs : DC 15 V ... 30 V Number of beams: 12 EMC: EN 60947-5-2
Specification: Part Number 1029489 Circuit protection: Output Q short-circuit protected Interference suppression VS connections reverse-polarity protected Number of beams: 16 Indication: LED Output mode : Q dark switching Task: Switching light grid Minimum detectable object (MDO): Parallel beam: &ge; 35 mm ... 65 mm Protection class: III Minimum range: &ge;0 mm Output load capacitive: 100 nF Connection
Specification: Part Number 1026537 Enclosure rating: IP 65 Shock load: 10 g / DIN EN 60068-2-29 / 16 ms Output load inductive: 1 H Test input: PNP Weight: 2,600 g Connection type: Male connector M12, 5-pin Technology: Sender/receiver Supply voltage Vs : DC 15 V ... 30 V Power consumption sender : < 100 mA Output current Imax.: 100 mA Minimum range: &ge;900 mm Maximum range: 17 m Housing mat
Specification: Part Number 1040580 Minimum range: &ge;500 mm Front screen: PMMA Supply voltage Vs : DC 15 V ... 30 V Response time : Parallel beam 300 ms Number of beams: 40 Wave length: 880 nm Switching output: 2 x PNP (Q and /Q) Ambient light safety: Indirect: &le; 150,000 lx Detection height: 1,170 mm Output current Imax.: 100 mA Technology: Sender/receiver Working range: 12 m Power cons
Specification: Part Number 1025618 Output mode : Q dark switching Working range: 12 m Circuit protection: Output Q short-circuit protected Interference suppression VS connections reverse-polarity protected Protection class: III Beam separation: 30 mm Indication: LED Number of beams: 48 Switching output: 2 x NPN (Q and /Q) Weight: 3,700 g Front screen: PMMA Output load capacitive: 100 nF Minimum
Specification: Part Number 1025620 Power consumption receiver : < 100 mA Connection type: Connector M12, 4-pin Output load inductive: 1 H Power consumption sender : < 100 mA Supply voltage Vs : DC 15 V ... 30 V Output load capacitive: 100 nF Weight: 4,300 g Number of beams: 56 Shock load: 10 g / DIN EN 60068-2-29 / 16 ms Switching frequency: 250 kHz Ripple: < 5 Vpp Working range: 12 m Fro
Specification: Part Number 1025621 Output current Imax.: 100 mA Supply voltage Vs : DC 15 V ... 30 V Weight: 4,800 g Power consumption receiver : < 100 mA Number of beams: 64 Working range: 12 m Vibration resistance: 5 g, 10 Hz ... 55 Hz (IEC 68-2-6) Ambient light safety: Indirect: &le; 150,000 lx Shock load: 10 g / DIN EN 60068-2-29 / 16 ms Protection class: III Switching output: 2 x NPN (Q and
Specification: Part Number 1025572 Maximum range: 17 m Number of beams: 70 Protection class: III Minimum range: &ge;500 mm Output load capacitive: 100 nF Test input: PNP Output load inductive: 1 H Front screen: PMMA Shock load: 10 g / DIN EN 60068-2-29 / 16 ms Wave length: 880 nm Evaluation beams: Multiple scan Response time : Parallel beam 390 ms Synchronization: Optical Technology: Se
Specification: Part Number 1043870 Ambient light safety: Indirect: &le; 150,000 lx Housing material: Aluminum Weight: 3,700 g Indication: LED Maximum range: 17 m Technology: Sender/receiver Protection class: III Vibration resistance: 5 g, 10 Hz ... 55 Hz (IEC 68-2-6) Working range: 12 m Output current Imax.: 100 mA Power consumption receiver : < 100 mA Wave length: 880 nm Output load induc
Specification: Part Number 1026183 Task: Switching light grid Evaluation beams: Parallel beam Maximum range: 17 m Detection height: 2,460 mm Weight: 6,200 g Supply voltage Vs : DC 15 V ... 30 V Output current Imax.: 100 mA Switching frequency: 250 kHz Enclosure rating: IP 65 Test input: PNP Ambient temperature: Operation: -25 ... +55 °C Storage: -40 ... +70 °C Minimum detectable object (MDO):
Specification: Part Number 6053120 Signal voltage LOW: &le; 2 V Outlet zone: 0 cm Wetted parts: PSU Nominal width measuring tube: NW 10 Minimim flow: 0.3 l/min Housing material: PSU Repeatability: &le; 0.5 % Response time: Filter off 100 ms, filter low 300 ms, filter medium 1 s, filter strong 4.2 s Impuls/frequency output: 0 kHz ... 10 kHz Enclosure rating: IP 67 Puls width: &le; 1 s Connectio
Specification: Part Number 6050189 Resolution: 0.006 l/min Output load: < 500 Ohm Wetted parts: PSU Signal voltage HIGH: Vs - 2 V Conductivity: No limitation Accuracy of sensor element: 1 % (of reading +/- 3 mm/s (with calibration report)) Ripple: &le; 5 Vpp Upper signal level: 20 mA ... 20.5 mA Weight: 350 g Inductive load: 1 H Minimim flow: 0.9 l/min Ambient temperature operation: 0 °C ..
Specification: Part Number 6050188 Process connection: Clamp (DIN 11864-3) Response time: Filter off 100 ms, filter low 300 ms, filter medium 1 s, filter strong 4.2 s Outlet zone: 10 cm Supply voltage: 18 V DC ... 30 V DC Inductive load: 1 H Nominal width measuring tube: NW 25 Capacitive load: 100 nF Repeatability: &le; 0.5 % Process pressure: Max. 10 bar Medium: Fluids Protection class: III S
Specification: Part Number 6047869 Connection type: Round connector M12 x 1, 5-pin Power consumption: &le; 180 mA Lower signal level: 3.8 mA ... 4 mA Puls width: &le; 1 s Repeatability: &le; 0.5 % Inductive load: 1 H Minimim flow: 0.9 l/min Protection class: III Inlet zone: 30 cm Supply voltage: 18 V DC ... 30 V DC Impuls/frequency output: 0 kHz ... 10 kHz Accuracy of sensor element: 2 % (of
Specification: Part Number 6047870 Output current: < 100 mA Process pressure: Max. 10 bar Supply voltage: 18 V DC ... 30 V DC Medium: Fluids Inlet zone: 50 cm Weight: 420 g Capacitive load: 100 nF Enclosure rating: IP 67 Impuls/frequency output: 0 kHz ... 10 kHz Upper signal level: 20 mA ... 20.5 mA Output load: < 500 Ohm Connection type: Round connector M12 x 1, 5-pin Resolution: 0.01
Specification: Part Number 1044077 Data transmission rate: &le;500 kbit/s Vibration resistance: 5 g, 10 Hz ... 500 Hz (EN 60068-2-6) Enclosure rating terminals: IP 20 (EN 60529) Type of fieldbus integration: Integrated device Ambient operating temperature: -25 °C ... +55 °C Electromagnetic compatibility (EMC): Class A (EN 61000-6-2, EN 55011) Protection class housing: IP 40 (EN 60529) Connection type: 1 x f
Specification: Part Number 1042896 Protection class: III (EN 61140) Scanning frequency: 25 Hz, at 1.3 megapixels resolution Ambient light safety: 2,000 lx, on bar code Remark (PROFIBUS DP): Optional via external connection module (CDM + CMF) Reading pulse: Non-powered, Switching inputs, Serial interface Dimensions: 112 mm x 80 mm x 39 mm Enclosure rating: IP 30, IP 65 (EN 60529) Electromagnetic compatibility
Specification: Part Number 1042897 Sensor: CMOS matrix sensor Function (Ethernet): Host, AUX, image transmission Dimensions: 112 mm x 80 mm x 39 mm Data transmission rate (CAN bus): 10 kbit/s ... 1 Mbit/s Enclosure rating: IP 30, IP 65 (EN 60529) Permissible relative humidity: ± 90 %, non-condensing DeviceNet: + Laser class: 1 (EN 60825-1) Ethernet: + Weight: 900 g, with connecting cable Reading
Specification: Part Number 1042277 Data transmission rate (Ethernet): 10/100 Mbit Ethernet: + MTBF: 75,000 h Protocol (Ethernet): TCP/IP, FTP (image transmission), PROFINET (optional via external connection module CDM) Data transmission rate (Serial (RS-232)): 300 Baud ... 57,600 Baud, AUX: 9,600 Baud Scanning frequency: 25 Hz, at 1.3 megapixels resolution No. of characters per reading interval: 4,000 2D code t
Specification: Part Number 1042338 Ambient light safety: 2,000 lx, on bar code Switching outputs: 2 (Result 1 NPN, Result 2 PNP) 2D code types: Data Matrix ECC200, GS1 Data-Matrix, QR code Dimensions: 112 mm x 80 mm x 39 mm Sensor resolution: 1,280 px x 1,024 px (1.3 Mpixel Data transmission rate (Serial (RS-232)): 300 Baud ... 57,600 Baud, AUX: 9,600 Baud Function (CAN bus): SICK CAN sensor network (Master/Slave,