Specification: Part Number 6047870 Output current: < 100 mA Process pressure: Max. 10 bar Supply voltage: 18 V DC ... 30 V DC Medium: Fluids Inlet zone: 50 cm Weight: 420 g Capacitive load: 100 nF Enclosure rating: IP 67 Impuls/frequency output: 0 kHz ... 10 kHz Upper signal level: 20 mA ... 20.5 mA Output load: < 500 Ohm Connection type: Round connector M12 x 1, 5-pin Resolution: 0.012 l/min Wetted parts: PSU Conductivity: No limitation Inductive load: 1 H Process temperature: 0 °C ... +80 °C Nominal width measuring tube: NW 20 Output signal: Analog output: 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature 1 pulse/status output: transistor output for flow rate meter, empty pipe detection, flow monitoring, dosing output, flow direction (depending on type) Response time: Filter off 100 ms, filter low 300 ms, filter medium 1 s, filter strong 4.2 s Maximum flow: 60 l/min Process connection: 1" NPT Protection class: III Lower signal level: 3.8 mA ... 4 mA Initialization time: ≤ 5 s Ripple: ≤ 5 Vpp Signal voltage HIGH: Vs - 2 V Ambient temperature operation: 0 °C ... +60 °C Power consumption: ≤ 180 mA Repeatability: ≤ 0.5 % Outlet zone: 10 cm Housing material: PSU Signal voltage LOW: ≤ 2 V Accuracy of sensor element: 2 % (of final value) Puls width: ≤ 1 s Minimim flow: 3.5 l/min Ambient storage temperature: -20 °C ... +70 °C