Specification: Part Number 1207935 External device monitoring (EDM): + Switching voltage LOW: 2 V DC Beam coding: + Power consumption: ≤ 3 A Restart interlock (delivery status): Deactivated Connection type: Male connector M12, 5-pin TM (mission time): 20 a (EN ISO 13849) Cascaded: - Type: Type 2 (IEC 61496) Test rate (internal test): 58 /s Maximum demand rate: 34 /min (EN ISO 13849) Conductor cross-section: 0.34 mm² External device monitoring (delivery status): Deactivated Typical range: 0 m ... 8 m Ripple: ≤ 10 % Automatic beam coding: + Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Safe state in the event of a fault: At least one OSSD is in the OFF state. Storage temperature: -25 °C ... +70 °C Configuration method: Hard wired Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Protective field height: 840 mm Weight: 300 g Display elements: LEDs Housing material: Aluminum alloy ALMGSI 0.5 Air humidity: 15 % ... 95 %, non-condensing PFHd: Standalone system: 2.4 1E-08 (EN ISO 13849) Permitted cable length: ≤ 20 m Enclosure rating: IP 65 (EN 60529) Housing cross-section (incl. system connection): 15 mm x 32 mm Scanning range: 0 m ... 6 m Ambient operating temperature: -20 °C ... +55 °C Response time: ≤ 17 ms Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Cable length: 700 mm Shock resistance: 10 g, 16 ms (EN 60068-2-27) Safe SICK device communication via EFI/SDL: - Synchronization: Optical, without separate synchronization Protection class: III (EN 61140) Switching current: 300 mA Resolution: 14 mm Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Category: Category 2 (EN ISO 13849) Restart interlock: + Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics!