Specification: Part Number 1207915 Typical range: 0 m ... 8 m Protection class: III (EN 61140) Scanning range: 0 m ... 6 m Type: Type 2 (IEC 61496) Safe SICK device communication via EFI/SDL: - Air humidity: 15 % ... 95 %, non-condensing Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Switching current: 300 mA TM (mission time): 20 a (EN ISO 13849) Housing material: Aluminum alloy ALMGSI 0.5 Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored External device monitoring (EDM): + Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Ambient operating temperature: -20 °C ... +55 °C Connection type: Male connector M12, 5-pin Permitted cable length: ≤ 20 m Protective field height: 780 mm Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Restart interlock: + Ripple: ≤ 10 % Cascaded: + Power consumption: ≤ 3 A Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Cable length: 700 mm Restart interlock (delivery status): Deactivated Safe state in the event of a fault: At least one OSSD is in the OFF state. Resolution: 34 mm Test rate (internal test): 47 /s Housing cross-section (incl. system connection): 15 mm x 32 mm Beam coding: + Automatic beam coding: + Connection type extension connection: Female connector M12, 5-pin PFHd: Cascaded systems: 5.2 1E-08 (EN ISO 13849) Enclosure rating: IP 65 (EN 60529) Maximum demand rate: 28 /min (EN ISO 13849) Conductor cross-section: 0.34 mm² Storage temperature: -25 °C ... +70 °C Switching voltage LOW: 2 V DC Display elements: LEDs Weight: 280 g Response time: ≤ 13 ms Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Shock resistance: 10 g, 16 ms (EN 60068-2-27) Synchronization: Optical, without separate synchronization Category: Category 2 (EN ISO 13849) External device monitoring (delivery status): Deactivated Configuration method: Hard wired