Specification: Part Number 1207836 Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Safety integrity level: SIL1 (IEC 61508) SILCL1 (EN 62061) Typical range: 0 m ... 8 m Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Shock resistance: 10 g, 16 ms (EN 60068-2-27) Test rate (internal test): 58 /s Permitted cable length: ≤ 20 m Conductor cross-section: 0.34 mm² External device monitoring (delivery status): Deactivated Response time: ≤ 13 ms Cable length: 700 mm Resolution: 24 mm Cascaded: - Switching current: 300 mA Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Restart interlock (delivery status): Deactivated Maximum demand rate: 34 /min (EN ISO 13849) Beam coding: + Display elements: LEDs Connection type: Male connector M12, 5-pin TM (mission time): 20 a (EN ISO 13849) Synchronization: Optical, without separate synchronization Automatic beam coding: + Protective field height: 600 mm Housing cross-section (incl. system connection): 15 mm x 32 mm Scanning range: 0 m ... 6 m Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! Housing material: Aluminum alloy ALMGSI 0.5 Configuration method: Hard wired Restart interlock: + Safe state in the event of a fault: At least one OSSD is in the OFF state. Type: Type 2 (IEC 61496) Category: Category 2 (EN ISO 13849) Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Safe SICK device communication via EFI/SDL: - Enclosure rating: IP 65 (EN 60529) Protection class: III (EN 61140) Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Ambient operating temperature: -20 °C ... +55 °C Air humidity: 15 % ... 95 %, non-condensing PFHd: Standalone system: 2.4 1E-08 (EN ISO 13849) Switching voltage LOW: 2 V DC Ripple: ≤ 10 % Power consumption: ≤ 3 A Storage temperature: -25 °C ... +70 °C Weight: 215 g External device monitoring (EDM): +