IFM Electronic - Position sensors

Image
Part Number
Description
Shortcode: IF-2004-N/1D/1G Output function: Normally closed Ambient temperature: -20...80 °C Length: 30 mm Switching frequency: 1500 Hz Mounting: non-flush mountable Current rating: < 30, when used outside the hazardous area mA Product Name: NF5003 Housing materials: PBT Connection: PVC cable / 2 m, 2 x 0.34 mm² Electrical design: Connection to certified intrinsically safe circuits with the max. value
Length: 30 mm Electrical design: Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P = 120 mW Output function: Normally closed Sensing range: 4 mm Ambient temperature: -20...80 °C Marking of the unit: ExII 1G Ex ia IIC T6 Ga Ta: -20…70° C ExII 1G Ex ia IIC T5 Ga Ta: -20…80° C ExII 1D Ex ia IIIC T90° C Da Ta: -20…70° C ExII 1D Ex ia IIIC T100° C Da Ta: -20…80° C M
Connection: PVC cable / 6 m, 2 x 0.34 mm² SKU 47TKE7UXD9ZTU6 Electrical design: Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P = 120 mW Product Name: NF5008 Housing materials: Brass special coating, active face: PC Nominal voltage: 8.2 DC, (1kΩ) V Sensing range: 4 mm Current rating: < 30, when used outside the hazardous area mA Mounting: non-flush mountable
Housing materials: Brass special coating, active face: PBT, connector: PA Output function: Normally closed Sensing range: 7 mm Marking of the unit: ExII 1G Ex ia IIC T6 Ga ExII 1D Ex ia IIIC T 90°C Da Product Name: NF500A Connection: M12 connector Length: 50 mm Electrical design: Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P = 120 mW Protection: IP 67 SKU
Connection: PVC cable / 6 m, 2 x 0.34 mm² Product Name: NF5010 Marking of the unit: ExII 1G Ex ia IIC T6 Ga Ta: -20…70° C ExII 1G Ex ia IIC T5 Ga Ta: -20…80° C ExII 1D Ex ia IIIC T90° C Da Ta: -20…70° C ExII 1D Ex ia IIIC T100° C Da Ta: -20…80° C Shortcode: IF-2004-N/6M/1D/1G SKU Q8L55PHWM9TOCR Housing materials: PBT Nominal voltage: 8.2 DC, (1kΩ) V Current rating: < 30, when used outside the hazard
Product Name: NF5012 Switching frequency: 1200 Hz Output function: Normally closed Electrical design: Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P = 120 mW Marking of the unit: ExII 1G Ex ia IIC T6 Ga Ta: -20…70° C ExII 1G Ex ia IIC T5 Ga Ta: -20…80° C ExII 1D Ex ia IIIC T90° C Da Ta: -20…70° C ExII 1D Ex ia IIIC T100° C Da Ta: -20…80° C Sensing range: 2 mm
Marking of the unit: ExII 1G Ex ia IIC T6 Ga ExII 1D Ex ia IIIC T 90°C Da Switching frequency: 700 Hz Connection: M12 connector Mounting: flush mountable SKU DKIBUL5ZA9BE7R Nominal voltage: 8.2 DC, (1kΩ) V Output status indication: LED yellow (4 x 90°) Length: 45 mm Protection: IP 67 Sensing range: 4 mm Shortcode: IFB2004BN/US/1G/1D Housing materials: Brass special coating, active face: PBT, connect
Connection: PVC cable / 20 m, 2 x 0.34 mm² Length: 30 mm Switching frequency: 1500 Hz Protection: IP 67 Current rating: < 30, when used outside the hazardous area mA Ambient temperature: -20...80 °C Electrical design: Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P = 120 mW Output function: Normally closed SKU GMVWAJUNGEH4JE Nominal voltage: 8.2 DC, (1kΩ) V
Code NF5029 Assembly flush mountable SKU 4HBWGVVE7AO6OD Housing dimentions: length 30 mm Output type normally closed Level of protection IP 67 Voltage category DC Switch frequency (Hz), DC 1200 Hz Temperature of surroundings -20...80 В°C sensitivity range 2 mm Degree of protection III Used materials PBT Technical code IF-2002-N/10M/1D/1G
Description: IFB2004BN/US/1G/1D Series: efe100,120,150 RG1
SKU 6KBAW94NDNC3A5 Connection: PVC cable / 6 m, 2 x 0.34 mm² Product Name: NF5030 Output function: Normally closed Mounting: non-flush mountable Protection: IP 67 Length: 30 mm Switching frequency: 1500 Hz Current rating: < 30, when used outside the hazardous area mA Ambient temperature: -20...80 °C Marking of the unit: ExII 1G Ex ia IIC T6 Ga Ta: -20…70° C ExII 1G Ex ia IIC T5 Ga Ta: -20…80° C
Case material: brass nickel-plated; PBT Voltage, nom. 8.2 DC; (1kО©) V Level of protection IP 67 Output type normally closed Switch frequency (Hz) 1200 Hz Assembly flush mountable Name of the product NF5031 Temperature of surroundings -20...70 В°C Technical code IFA2002-N/12M/PH Joining PUR cable / 12 m; 2 x 0.34 mmВІ Sensitivity range 2 mm Dimentions: Length 30 mm SKU IA91PQBRALH1Z9
Description: IFA2002-N/1G Series: efe100,120,150 RG1
Description: IFA2004-N/1G Series: efe100,120,150 RG1
Used materials stainless steel- PBT Switch frequency (Hz), DC 1500 Hz Temperature of surroundings -20...80 В°C Voltage category DC Assembly non-flush mountable Technical code IFA2004-N/V2A/20M/1D/1G Output type normally closed Level of protection IP 67 sensitivity range 4 mm Housing dimentions: length 30 mm Degree of protection III Code NF5037 SKU DDZN5LLK8H6CW1
Description: IF-2004-N/F/0,135M Series: efe100,120,150 RG1
Description: IF-2004-N/0,135M Series: efe100,120,150 RG1
Description: IFB20,5-N/0,5M/1G Series: efe100,120,150 RG1
Technical code IFB2004BN/M/V4A/US Continuous rated power of DC switching output 30 mA Voltage category DC Code NFT201 Link M12 Connector SKU II2F9S6516PADY Working voltage, DC 7.5...30 V Level of protection IP 67 Output type normally closed Display type switching status: 4 x 90В° LED yellow sensitivity range 4 mm Housing dimentions: length 45 mm Assembly flush mountable Degree of protection I
Product Name: NG5001 Nominal voltage: 8.2 DC, (1kΩ) V Electrical design: Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P = 120 mW Switching frequency: 720 Hz Sensing range: 5 mm Length: 33 mm Ambient temperature: -20...80 °C Shortcode: IG-2005-N/1D/1G SKU JWYFPGIPFJPLD2 Output function: Normally closed Housing materials: PBT Current rating: < 30, w
Mounting: flush mountable Output function: Normally closed Nominal voltage: 8.2 DC, (1kΩ) V Marking of the unit: ExII 1G Ex ia IIB T6 Ga ExII 2G Ex ia IIC T6 Gb ExII 1D Ex ia IIIC T 90°C Da Electrical design: Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P = 120 mW Switching frequency: 720 Hz SKU AC44B0QMDD6MJS Connection: PVC cable / 2 m, 2 x 0.5 mm² Product Nam
Output function: Normally closed Nominal voltage: 8.2 DC, (1kΩ) V Connection: PVC cable / 2 m, 2 x 0.5 mm² Mounting: non-flush mountable Length: 33 mm Current rating: < 30, when used outside the hazardous area mA Switching frequency: 300 Hz Electrical design: Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P = 120 mW Product Name: NG5003 Housing materials: P
Ambient temperature: -20...80 °C SKU QS1Y7VGYJV7GYF Shortcode: IGA2008-N/1D/1G/2G Protection: IP 67 Current rating: < 30, when used outside the hazardous area mA Mounting: non-flush mountable Sensing range: 8 mm Marking of the unit: ExII 1G Ex ia IIB T6 Ga ExII 2G Ex ia IIC T6 Gb ExII 1D Ex ia IIIC T 90°C Da Switching frequency: 300 Hz Product Name: NG5004 Nominal voltage: 8.2 DC, (1kΩ) V Housing
Nominal voltage: 8.2 DC, (1kΩ) V Output function: Normally closed Current rating: < 30, when used outside the hazardous area mA Sensing range: 12 mm Protection: IP 67 Switching frequency: 300 Hz Length: 51 mm Ambient temperature: -20...70 °C Shortcode: IGB2012-N/US/1G/1D Housing materials: Brass special coating, active face: PBT, connector: PA Marking of the unit: ExII 1G Ex ia IIC T6 Ga ExII 1D Ex ia I
Ambient temperature: -20...80 °C Output function: Normally closed Protection: IP 67 Housing materials: Brass white bronze coated, active face: PBT Nominal voltage: 8.2 DC, (1kΩ) V Connection: PVC cable / 10 m, 2 x 0.5 mm² Product Name: NG5010 SKU MZHJADZY3BPUVR Shortcode: IGA2008-N/10M/1D/1G/2G Mounting: non-flush mountable Switching frequency: 300 Hz Marking of the unit: ExII 1G Ex ia IIB T6 Ga E
Nominal voltage: 8.2 DC, (1kΩ) V Shortcode: IGA2005-N/10M/1D/1G/2G Output function: Normally closed Product Name: NG5011 Mounting: flush mountable Ambient temperature: -20...80 °C SKU 48LQPGMOM92RDW Switching frequency: 720 Hz Electrical design: Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P = 120 mW Housing materials: Brass white bronze coated, active fac
Shortcode: IG-2008-N/15M/1D/1G/2G Electrical design: Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P = 120 mW Housing materials: PBT Protection: IP 67 Product Name: NG5016 Mounting: non-flush mountable Ambient temperature: -20...80 °C Connection: PVC cable / 15 m, 2 x 0.5 mm² Length: 33 mm SKU ODXDF5U0M35H5Y Marking of the unit: ExII 1G Ex ia IIB T6 Ga
Length: 33 mm Product Name: NG5019 Marking of the unit: ExII 1G Ex ia IIB T6 Ga ExII 2G Ex ia IIC T6 Gb ExII 1D Ex ia IIIC T 90°C Da Output function: Normally closed Connection: PVC cable / 6 m, 2 x 0.5 mm² SKU 4WDMJGI32JHAWD Protection: IP 67 Mounting: flush mountable Nominal voltage: 8.2 DC, (1kΩ) V Shortcode: IG-2005-N/6M/1D/1G/2G Electrical design: Connection to certified intrinsically safe circui
Ambient temperature: -20...70 °C Length: 46 mm Shortcode: IGB2008BN/US/1G/1D Output status indication: LED yellow (4 x 90°) Nominal voltage: 8.2 DC, (1kΩ) V Marking of the unit: ExII 1G Ex ia IIC T6 Ga ExII 1D Ex ia IIIC T 90°C Da SKU 9HYV5JB1AW9YZ7 Output function: Normally closed Protection: IP 67 Housing materials: Brass special coating, active face: PBT, connector: PA Electrical design: Connection
Switching frequency: 300 Hz Output function: Normally closed Sensing range: 8 mm Current rating: < 30, when used outside the hazardous area mA Electrical design: Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P = 120 mW Housing materials: Brass white bronze coated, active face: PBT Ambient temperature: -20...80 °C Marking of the unit: ExII 1G Ex ia IIB T6 Ga ExII 2G E