Product Name: NF5012 Switching frequency: 1200 Hz Output function: Normally closed Electrical design: Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P = 120 mW Marking of the unit: ExII 1G Ex ia IIC T6 Ga Ta: -20…70° C ExII 1G Ex ia IIC T5 Ga Ta: -20…80° C ExII 1D Ex ia IIIC T90° C Da Ta: -20…70° C ExII 1D Ex ia IIIC T100° C Da Ta: -20…80° C Sensing range: 2 mm Current rating: < 30, when used outside the hazardous area mA Connection: PVC cable / 6 m, 2 x 0.34 mm² Housing materials: Brass white bronze coated, active face: PC Nominal voltage: 8.2 DC, (1kΩ) V Ambient temperature: -20...80 °C Length: 30 mm Mounting: flush mountable Protection: IP 67 SKU 06Q9RX11P1665P Shortcode: IFA2002-N/6M/1D/1G