Housing materials: PBT Protection: IP 67 Switching frequency: 450 Hz Connection: PVC cable / 2 m, 2 x 0.5 mm² Marking of the unit: ExII 1G Ex ia IIB T6 Ga ExII 2G Ex ia IIC T6 Gb ExII 1D Ex ia IIIC T 90°C Da Mounting: flush mountable Product Name: NI5001 Nominal voltage: 8.2 DC, (1kΩ) V Shortcode: II-2010-N/1D/1G/2G SKU 1DRM2DVK9W4X5E Output function: Normally closed Length: 41 mm Ambient tempe
Marking of the unit: ExII 1G Ex ia IIB T6 Ga ExII 2G Ex ia IIC T6 Gb ExII 1D Ex ia IIIC T 90°C Da Length: 41 mm Protection: IP 67 Electrical design: Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P = 120 mW Connection: PVC cable / 2 m, 2 x 0.5 mm² Current rating: < 30, when used outside the hazardous area mA Shortcode: IIA2010-N/1D/1G Product Name: NI5002 Housin
Marking of the unit: ExII 1G Ex ia IIB T6 Ga ExII 2G Ex ia IIC T6 Gb ExII 1D Ex ia IIIC T 90°C Da Nominal voltage: 8.2 DC, (1kΩ) V Ambient temperature: -20...80 °C Housing materials: PBT Switching frequency: 200 Hz Length: 41 mm Current rating: < 30, when used outside the hazardous area mA Connection: PVC cable / 2 m, 2 x 0.5 mm² SKU SPEFVADYWHTK5F Output function: Normally closed Mounting: non-flush
Current rating: < 30, when used outside the hazardous area mA Housing materials: Brass special coating, active face: PBT Product Name: NI5004 Nominal voltage: 8.2 DC, (1kΩ) V Output function: Normally closed Electrical design: Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P = 120 mW SKU 0M8YZYO9OAKS1P Mounting: non-flush mountable Ambient temperature: -20...80
Nominal voltage: 8.2 DC, (1kΩ) V Protection: IP 67 Ambient temperature: -20...70 °C Output function: Normally closed Shortcode: IIB2022-N/US/1G/1D Connection: M12 connector Switching frequency: 100 Hz Product Name: NI500A Mounting: non-flush mountable Sensing range: 22 mm Output status indication: LED yellow (4 x 90°) Current rating: < 30, when used outside the hazardous area mA Marking of the
Mounting: non-flush mountable Protection: IP 67 Output function: Normally closed Shortcode: II-2015-N/10M/1D/1G/2G Current rating: < 30, when used outside the hazardous area mA Product Name: NI5011 Connection: PVC cable / 10 m, 2 x 0.5 mm² Sensing range: 15 mm Switching frequency: 200 Hz Marking of the unit: ExII 1G Ex ia IIB T6 Ga ExII 2G Ex ia IIC T6 Gb ExII 1D Ex ia IIIC T 90°C Da Ambient temperatur
SKU EHBZ54QUF4X7TL Ambient temperature: -20...80 °C Housing materials: Brass special coating, active face: PBT Current rating: < 30, when used outside the hazardous area mA Sensing range: 10 mm Shortcode: IIA2010-N/10M/1D/1G/2G Marking of the unit: ExII 1G Ex ia IIB T6 Ga ExII 2G Ex ia IIC T6 Gb ExII 1D Ex ia IIIC T 90°C Da Product Name: NI5012 Output function: Normally closed Mounting: flush mountable
Current rating: < 30, when used outside the hazardous area mA Length: 50 mm Output status indication: LED yellow (4 x 90°) Sensing range: 15 mm Electrical design: Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P = 120 mW Output function: Normally closed Switching frequency: 100 Hz Connection: M12 connector Nominal voltage: 8.2 DC, (1kΩ) V Ambient temperature:
Protection: IP 67 Ambient temperature: -20...70 °C Output function: Normally closed Shortcode: IMC2020BN/US/2G/1D Switching frequency: 200 Hz Housing materials: housing: PPE, end cap: PPS, connector housing: Brass special coating, Mounting adapter: PPS Marking of the unit: ExII 2G Ex ia IIB T6 Gb ExII 1D Ex ia IIIC T 90°C Da Mounting: flush mountable Output status indication: LED yellow Product Name: NM500A
Protection: IP 67 Output function: Normally closed Current rating: < 30, when used outside the hazardous area mA Ambient temperature: -20...70 °C Connection: M12 connector Electrical design: Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P = 120 mW Mounting: non-flush mountable Shortcode: IMC2035-N/US/2G/1D Nominal voltage: 8.2 DC, (1kΩ) V Housing materials:
Switching frequency: 800 Hz Connection: PVC cable / 2 m, 2 x 0.5 mm² Shortcode: IN-2002-N/1D/1G/2G Product Name: NN5001 SKU QZM4F9SQ0AG1P2 Protection: IP 67 Sensing range: 2 mm Output function: Normally closed Housing materials: PBT Electrical design: Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P = 120 mW Ambient temperature: -20...80 °C Nominal vo
Switching frequency: 400 Hz Protection: IP 67 Shortcode: IN-2004-N/1D/1G/2G Current rating: < 30, when used outside the hazardous area mA Electrical design: Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P = 120 mW SKU 08PQFRL1WALE7P Housing materials: PBT Product Name: NN5002 Mounting: non-flush mountable Marking of the unit: ExII 1G Ex ia IIB T6 Ga ExII 2G
Switching frequency: 1800 Hz Protection: IP 67 Output function: 2 x normally closed Sensing range: 4 mm Housing materials: housing: PBT, cover: PC Marking of the unit: ExII 1G Ex ia IIB T6 Ga Ta: -20...70°C ExII 2G Ex ia IIC T6 Gb Ta: -20...70°C ExII 1D Ex ia IIIC T 90°C Da Ta: -20...70°C ExII 1G Ex ia IIB T5 Ga Ta: -20...80°C ExII 2G Ex ia IIC T5 Gb Ta: -20...80°C ExII 1D Ex ia IIIC T 100°C Da Ta: -20...80°C Ambie
Marking of the unit: ExII 1G Ex ia IIB T6 Ga Ta: -20...70°C ExII 2G Ex ia IIC T6 Gb Ta: -20...70°C ExII 1D Ex ia IIIC T 90°C Da Ta: -20...70°C ExII 1G Ex ia IIB T5 Ga Ta: -20...80°C ExII 2G Ex ia IIC T5 Gb Ta: -20...80°C ExII 1D Ex ia IIIC T 100°C Da Ta: -20...80°C Switching frequency: 1800 Hz Electrical design: Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P = 120 mW Mounting:
Product Name: NN5011 Ambient temperature: -20...80 °C Marking of the unit: ExII 1G Ex ia IIB T6 Ga Ta: -20...70°C ExII 2G Ex ia IIC T6 Gb Ta: -20...70°C ExII 1D Ex ia IIIC T 90°C Da Ta: -20...70°C ExII 1G Ex ia IIB T5 Ga Ta: -20...80°C ExII 2G Ex ia IIC T5 Gb Ta: -20...80°C ExII 1D Ex ia IIIC T 100°C Da Ta: -20...80°C Protection: IP 67 Mounting: non-flush mountable Output function: 2 x normally closed Shortcode:
Output function: 2 x normally closed Sensing range: 4 mm Marking of the unit: ExII 1G Ex ia IIB T6 Ga Ta: -20...70°C ExII 2G Ex ia IIC T6 Gb Ta: -20...70°C ExII 1D Ex ia IIIC T 90°C Da Ta: -20...70°C ExII 1G Ex ia IIB T5 Ga Ta: -20...80°C ExII 2G Ex ia IIC T5 Gb Ta: -20...80°C ExII 1D Ex ia IIIC T 100°C Da Ta: -20...80°C Electrical design: Connection to certified intrinsically safe circuits with the max. values U = 15 V / I =