Baumer - Encoders

Image
Part Number
Description
Function Singleturn Size (flange) ø58 mm Initializing time ≤500 ms after power on Interface analog 0...10 V / 0.5...4.5 V / 4...20 mA Resolution: 12 bit Diagnostic functions Self-diagnosis Reading back voltage output Resistance DIN EN 60068-2-6 Vibration 30 g, 10-2000 Hz DIN EN 60068-2-27 Shock 100 g, 6 ms Short-circuit proof Yes Teach range 10°...359.9° Reverse polarity protection
Sensing method Magnetic Function Singleturn Initializing time typ. 500 ms after power on Diagnostic functions Multiturn sensing Position error Consumption w/o load ≤80 mA (24 VDC) Programmable parameters Operating modes Total resolution Scaling Shaft type ø12 mm (blind hollow shaft) ø15 mm (blind hollow shaft) Steps per turn ≤4096 / 12 bit Operating speed ≤6000 rpm Size
Operating temperature -20...+65 °C Sensing method Magnetic Protection DIN EN 60529 IP 65 Resistance DIN EN 60068-2-6 Vibration 30 g, 10-2000 Hz DIN EN 60068-2-27 Shock 500 g, 6 ms Diagnostic functions Position or parameter error Multiturn sensing Operating speed ≤12000 rpm (mechanical) ≤6000 rpm (electric) Emitted interference DIN EN 61000-6-3 Code sequence CW default, programmable Interfac
manufacter SKU BMSH 58 DeviceNet - MAGRES Profile conformity Device Profile Encoder V 1.0 Code sequence CW default, programmable Sensing method Magnetic Absolute accuracy ±1 ° Steps per turn ≤4096 / 12 bit Approval UL approval / E217823 Emitted interference DIN EN 61000-6-3 Operating temperature -20...+85 °C Size (flange) ø58 mm Interface DeviceNet Connection Connector
Resistance DIN EN 60068-2-6 Vibration 30 g, 10-2000 Hz DIN EN 60068-2-27 Shock 200 g, 6 ms Status indicator DUO-LED integrated in bus cover Shaft type ø12 mm (blind hollow shaft) ø15 mm (blind hollow shaft) Sensing method Magnetic Starting torque ≤2 Ncm (+20 °C, IP 65) ≤2.5 Ncm (+20 °C, IP 67) Consumption w/o load ≤200 mA (24 VDC) Relative humidity 95 % Angular accuracy ±0.5
Operating speed ≤12000 rpm (mechanical) ≤6000 rpm (electric) Interface 12 parallel outputs Inputs Zero setting input Absolute accuracy ±1 ° Emitted interference DIN EN 61000-6-3 Operating torque typ. 0.0093 Nm Sensing method Magnetic manufacter SKU BMSH 58 parallel - MAGRES Operating temperature -20...+85 °C Interference immunity DIN EN 61000-6-2 Size (flange) ø58 mm
Emitted interference DIN EN 61000-6-3 Consumption w/o load ≤150 mA (5 VDC) ≤60 mA (24 VDC) Inputs SSI clock: Linereceiver RS422 Zero setting input Interference immunity DIN EN 61000-6-2 Weight approx. 300 g Repeatability 0.3 ° Angular accuracy ±0.5 ° Operating temperature -40...+85 °C (see general informations) Resistance DIN EN 60068-2-6 Vibration 30 g, 10-2000 Hz DIN EN 60068-2-27 Sh
Code sequence CW: ascending values with clockwise sense of rotation; looking at flange manufacter SKU BMSK 30 SSI - MAGRES Approval UL approval / E217823 Emitted interference DIN EN 61000-6-3 Interference immunity DIN EN 61000-6-2 Function Singleturn Voltage supply 5 VDC ±10 % 10...30 VDC Protection DIN EN 60529 IP 67 Output stages SSI data: linedriver RS485 Operating temperature -20...+85 °
Size (flange) ø42 mm Shaft type ø6 mm (magnet bore) manufacter SKU BMSK 42 CANopen - MAGRES Absolute accuracy ±1 ° Weight approx. 190 g Interface CANopen® Code Binary Function Singleturn Initializing time typ. 170 ms after power on Connection Connector M12, 5-pin Cable Resistance DIN EN 60068-2-6 Vibration 30 g, 10-2000 Hz DIN EN 60068-2-27 Shock 500 g, 6 ms Emitt
Relative humidity 95 % Interference immunity DIN EN 61000-6-2 Approval UL approval / E217823 Materials Housing: steel/aluminium Flange: aluminium Emitted interference DIN EN 61000-6-3 Weight approx. 50 g Shaft type ø6 mm (magnet bore) Resistance DIN EN 60068-2-6 Vibration 30 g, 10-2000 Hz DIN EN 60068-2-27 Shock 100 g, 6 ms Inputs Zero setting input Gap tolerance ≤0.3 mm axial &
Protection DIN EN 60529 IP 67 Function Singleturn Code Gray or binary Materials Housing: steel/aluminium Flange: aluminium Shaft type ø6 mm (magnet bore) Relative humidity 95 % Operating speed ≤12000 rpm (mechanical) ≤6000 rpm (electric) Initializing time typ. 170 ms after power on Interference immunity DIN EN 61000-6-2 Weight approx. 50 g Interface SSI Voltage supply
Profile conformity CANopen® CiA DSP 301 4.01, DSP 305 V1.0, DSP 406 V3.0 Consumption typ. 100 mA (24 VDC, w/o load) Connection Connector M12 Connector D-SUB, 9-pin Cable Weight approx. 300 g Protection DIN EN 60529 IP 67 Code sequence CW default, programmable Code Binary Programmable parameters Operating modes Total resolution Scaling Rotation speed monitoring Function Singleturn Operating t
Emitted interference DIN EN 61000-6-3 Steps per turn ≤4096 / 12 bit Sensing method Magnetic Weight approx. 480 g Status indicator DUO-LED integrated in bus cover Resistance DIN EN 60068-2-6 Vibration 30 g, 10-2000 Hz DIN EN 60068-2-27 Shock 200 g, 6 ms Code sequence CW default, programmable Code Binary Diagnostic functions Position or parameter error Multiturn sensing Connection Bus cov
Connection Cable 2 m Steps per turn 4096 / 12 bit Initializing time typ. 170 ms after power on Voltage supply 10...30 VDC Interface 12 parallel outputs Absolute accuracy ±1 ° Consumption typ. 50 mA (24 VDC, w/o load) Relative humidity 95 % Emitted interference DIN EN 61000-6-3 Function Singleturn Code Gray or binary Inputs Zero setting input Operating temperature -20...+8
Resistance DIN EN 60068-2-6 Vibration 30 g, 10-2000 Hz DIN EN 60068-2-27 Shock 100 g, 6 ms Voltage supply 5 VDC ±10 % 10...30 VDC manufacter SKU BMSK 58 SSI - MAGRES Code sequence CW: ascending values with clockwise sense of rotation; looking at flange Approval UL approval / E217823 Code Gray or binary Protection DIN EN 60529 IP 67 Operating speed ≤12000 rpm (mechanical) ≤6000 rpm (electric)
Protection DIN EN 60529 IP 65 Interference immunity DIN EN 61000-6-2 Operating speed ≤6000 rpm Absolute accuracy ±1 ° Relative humidity 95 % Interface SSI Approval UL approval / E217823 Admitted shaft load ≤10 N axial ≤10 N radial Materials Housing: steel Flange: aluminium Connection Connector M12, 8-pin Cable 2 m manufacter SKU BMSV 30 SSI - MAGRES Inputs SSI clock Zero
Protection DIN EN 60529 IP 67 Interface SSI Shaft type ø6 mm solid shaft ø8 mm solid shaft Approval UL approval / E217823 Emitted interference DIN EN 61000-6-3 Function Singleturn Operating speed ≤6000 rpm Code sequence CW: ascending values with clockwise sense of rotation; looking at flange Resistance DIN EN 60068-2-6 Vibration 30 g, 10-2000 Hz DIN EN 60068-2-27 Shock 500 g, 6
Shaft type ø6 mm solid shaft ø10 mm solid shaft Code Binary Absolute accuracy ±1 ° Operating temperature -20...+85 °C Admitted shaft load ≤10 N axial ≤25 N radial Consumption typ. 100 mA (24 VDC, w/o load) Emitted interference DIN EN 61000-6-3 Voltage supply 10...30 VDC Weight approx. 190 g Steps per turn ≤4096 / 12 bit Interference immunity DIN EN 61000-6-2
Voltage supply 10...30 VDC Protection DIN EN 60529 IP 65 Approval UL approval / E217823 Weight approx. 190 g manufacter SKU BMSV 42 DeviceNet - MAGRES Code sequence CW default, programmable Shaft type ø6 mm solid shaft ø10 mm solid shaft Code Binary Sensing method Magnetic Size (flange) ø42 mm Resistance DIN EN 60068-2-6 Vibration 30 g, 10-2000 Hz DIN EN 60068-2-27
manufacter SKU BMSV 42 parallel - MAGRES Interface 9 parallel outputs Sensing method Magnetic Approval UL approval / E217823 Initializing time typ. 170 ms after power on Function Singleturn Materials Housing: steel Flange: aluminium Voltage supply 5 VDC ±10 % Emitted interference DIN EN 61000-6-3 Inputs Zero setting input Resistance DIN EN 60068-2-6 Vibration 30 g, 10-2000 Hz DIN EN 60
Steps per turn 4096 / 12 bit Interface SSI Size (flange) ø42 mm Admitted shaft load ≤10 N axial ≤25 N radial Sensing method Magnetic Emitted interference DIN EN 61000-6-3 Weight approx. 120 g Initializing time typ. 170 ms after power on Resistance DIN EN 60068-2-6 Vibration 30 g, 10-2000 Hz DIN EN 60068-2-27 Shock 500 g, 6 ms Connection Connector M12, 8-pin Cable Code Gr
Relative humidity 95 % Operating torque typ. 0.0023 Nm Absolute accuracy ±1 ° Function Singleturn Size (flange) ø58 mm Weight approx. 300 g Teach range 10°...359.9° manufacter SKU BMSV 58K analog - MAGRES Factory setting 1 revolution Linearity 0.06 % of measuring range (10 revolutions) 0.17 % of measuring range (2 revolutions) 0.31 % of measuring range (360°) 0.6 % of measuring ran
Repeatability 0.3 ° Sensing method Magnetic Size (flange) ø58 mm Consumption w/o load ≤80 mA (24 VDC) Admitted shaft load ≤40 N axial ≤80 N radial Interface CANopen® Flange Clamping flange Programmable parameters Operating modes Total resolution Scaling Code sequence CW default, programmable Profile conformity CANopen® CiA DS 301, DSP 305, DS 406 Materials Housing:
Operating speed ≤12000 rpm (mechanical) ≤6000 rpm (electric) Absolute accuracy ±1 ° Function Singleturn Resistance DIN EN 60068-2-6 Vibration 30 g, 10-2000 Hz DIN EN 60068-2-27 Shock 500 g, 6 ms Size (flange) ø58 mm Admitted shaft load ≤40 N axial ≤60 N radial Flange Clamping flange Diagnostic functions Position or parameter error Multiturn sensing Sensing method Magnetic
Sensing method Magnetic Interface DeviceNet Absolute accuracy ±1 ° Function Singleturn Consumption typ. 100 mA (24 VDC, w/o load) Weight approx. 300 g Connection Connector D-SUB, 9-pin Diagnostic functions Position or parameter error Multiturn sensing Code sequence CW default, programmable Approval UL approval / E217823 Shaft type ø10 mm solid shaft (clamping flange) manuf
Programmable parameters Steps per revolution Number of revolutions Preset Scaling Rotating direction Operating temperature -40...+85 °C (see general informations) Interfaces CANopen® DeviceNet EtherCAT EtherNet/IP Profibus-DPV0/V2 PROFINET POWERLINK SAEJ1939 Shaft type ø10 x 20 mm, solid shaft with flat (clamping flange) Admitted shaft load ≤40 N axial ≤80 N radial Diagnostic functions Multiturn sen
Code Gray or binary Size (flange) ø58 mm Operating speed ≤12000 rpm (mechanical) ≤6000 rpm (electric) Initializing time typ. 170 ms after power on Operating torque typ. 0.023 Nm Materials Housing: aluminium Flange: aluminium Protection DIN EN 60529 IP 65 Weight approx. 300 g Interference immunity DIN EN 61000-6-2 Shaft type ø10 mm solid shaft (clamping flange) manufac
manufacter SKU BMSV 58K SSI - MAGRES Admitted shaft load ≤40 N axial ≤80 N radial Output stages SSI data: Linedriver RS422 Inputs SSI clock: Linereceiver RS422 Zero setting input Angular accuracy ±0.5 ° Consumption w/o load ≤150 mA (5 VDC) ≤60 mA (24 VDC) Operating temperature -40...+85 °C (see general informations) Steps per turn 4096 / 12 bit Function Singleturn Shaft type &os
Materials Housing: aluminium Flange: aluminium Sensing method Magnetic Code sequence CW: ascending values with clockwise sense of rotation; looking at flange Absolute accuracy ±1 ° Steps per turn ≤4096 / 12 bit Voltage supply 8...30 VDC Initializing time ≤500 ms after power on Operating torque typ. 0.0023 Nm Factory setting 1 revolution Response time Consumption typ. 35 mA (24
Materials Housing: steel zinc-coated Flange: aluminium Solid shaft: stainless steel Code Binary Code sequence CW default, programmable Interface CANopen® Size (flange) ø58 mm Emitted interference DIN EN 61000-6-3 Programmable parameters Operating modes Total resolution Scaling Admitted shaft load ≤40 N axial ≤80 N radial Initializing time typ. 500 ms after power on Resistance
Menu
Mail Us
enquiry@onstocktrading.com