Baumer - Encoders

Image
Part Number
Description
Consumption typ. 50 mA (24 VDC, w/o load) Interference immunity DIN EN 61000-6-2 Number of steps 50000 (5000 mm) manufacter SKU BMMS K50 SSI / cable-pull - MAGRES Inputs SSI clock Zero setting input Distance/revolution 239.7 ±0,6 mm Sensing method Magnetic Relative humidity 95 % Resolution 0.1 mm/step Interface SSI Operating temperature -40...+85 °C Function Multiturn Voltage
Short-circuit proof Yes Service life Type >500000 strokes Special characteristics Coated electronic Sensing method Magnetic Operating temperature -40...+85 °C Repeatability typ. 3 mm Bending radius Cable: >55 mm Response time Weight approx. 900 g Relative humidity 95 % temporary condensing Linearity 0.2 % of whole measuring range manufacter SKU BMMS M50 analog / cable-pull - MAG
Materials Encoder housing: aluminium Cable-pull housing: PA6 GF30 Cable: Stainless steel cable sheathed with polyamide Protection DIN EN 60529 IP 65 (encoder) Consumption typ. 35 mA (24 VDC, w/o load) Pull-in force >7 N Instruction Please consider the assembly instructions Voltage supply 8...30 VDC Cable diameter 0.45 mm Reverse polarity protection Yes Pull-out force ≤13 N Weight approx.
Emitted interference DIN EN 61000-6-3 Distance/revolution 333.32 ±0,3 mm Weight approx. 900 g Code Binary Relative humidity 95 % Linearity 0.16 % of whole measuring range Code sequence Programmable Profile conformity CANopen® CiA DSP 301 4.01, DSP 305 V1.0, DSP 406 V3.0 Operating temperature -40...+85 °C Resolution 0.1 mm/step Diagnostic functions Position or parameter error Multitu
Code Gray or binary Number of turns 8192 / 13 bit Consumption typ. 100 mA (5 VDC, w/o load) 50 mA (24 VDC, w/o load) Steps per turn 4096 / 12 bit Voltage supply 5 VDC ±10 % 10...30 VDC Output stages SSI data: linedriver RS485 Operating torque typ. 0.0075 Nm Initializing time typ. 70 ms after power on Code sequence CW: ascending values with clockwise sense of rotation; looking at flange Materi
Shaft type ø6 mm solid shaft ø8 mm solid shaft Connection Connector M12, 8-pin Cable 2 m Output stages SSI data: linedriver RS485 Steps per turn 4096 / 12 bit Consumption typ. 100 mA (5 VDC, w/o load) 50 mA (24 VDC, w/o load) Initializing time typ. 70 ms after power on Absolute accuracy ±1 ° Operating speed ≤6000 rpm Resistance DIN EN 60068-2-6 Vibration 30 g, 10-2000 Hz DIN EN
Initializing time typ. 170 ms after power on Approval UL approval / E217823 Diagnostic functions Position or parameter error Multiturn sensing Admitted shaft load ≤10 N axial ≤25 N radial Operating torque typ. 0.026 Nm Size (flange) ø42 mm Weight approx. 190 g Interference immunity DIN EN 61000-6-2 Code Binary Materials Housing: steel Flange: aluminium Absolute accuracy ±
Resistance DIN EN 60068-2-6 Vibration 30 g, 10-2000 Hz DIN EN 60068-2-27 Shock 500 g, 6 ms Voltage supply 10...30 VDC Steps per turn ≤4096 / 12 bit Protection DIN EN 60529 IP 65 Interface DeviceNet Operating speed ≤12000 rpm (mechanical) ≤6000 rpm (electric) Shaft type ø6 mm solid shaft ø10 mm solid shaft Sensing method Magnetic Operating torque typ. 0.026 Nm Diagnosti
Interference immunity DIN EN 61000-6-2 Operating temperature -20...+85 °C Initializing time typ. 170 ms after power on Weight approx. 190 g Voltage supply 5 VDC ±10 % 10...30 VDC Materials Housing: steel Flange: aluminium Admitted shaft load ≤10 N axial ≤25 N radial Number of turns 8192 / 13 bit Interface SSI Code Gray or binary Operating torque typ. 0.026 Nm Approval UL
Operating temperature -40...+85 °C Initializing time ≤500 ms after power on Response time Admitted shaft load ≤40 N axial ≤60 N radial Teach range 10°...32767 turns Weight approx. 300 g Programmable parameters Measuring range teachable Resistance DIN EN 60068-2-6 Vibration 30 g, 10-2000 Hz DIN EN 60068-2-27 Shock 500 g, 6 ms Number of turns ≤65536 / 16 bit Size (flange) &os
Angular accuracy ±0.5 ° Function Multiturn Code sequence CW default, programmable Relative humidity 95 % Repeatability 0.3 ° Operating speed ≤6000 rpm Number of turns ≤262144 / 18 bit Approval UL approval / E217823 Shaft type ø10 x 20 mm, solid shaft with flat (clamping flange) Diagnostic functions Multiturn sensing Position error Profile conformity CANopen® CiA DS 301
Admitted shaft load ≤120 N axial (combined) ≤280 N radial (combined) ≤270 N axial (concentrated load) Absolute accuracy ±1 ° Flange Clamping flange Operating speed ≤6000 rpm Steps per turn ≤4096 / 12 bit Resistance DIN EN 60068-2-6 Vibration 30 g, 10-2000 Hz DIN EN 60068-2-27 Shock 500 g, 6 ms Programmable parameters Operating modes Total resolution Scaling Rotation speed monitoring Op
Protection DIN EN 60529 IP 65 manufacter SKU BMMV 58K CANopen® - MAGRES redundant Flange Clamping flange Programmable parameters Operating modes Total resolution Scaling Rotation speed monitoring Initializing time typ. 500 ms after power on Voltage supply 10...30 VDC Code Binary Connection Connector M12 Cable Interface CANopen® Sensing method Magnetic Emitted interference DIN EN 61000
Voltage supply 10...30 VDC Emitted interference DIN EN 61000-6-3 Interference immunity DIN EN 61000-6-2 Connection Connector D-SUB, 9-pin Size (flange) ø58 mm Admitted shaft load ≤40 N axial ≤60 N radial Operating speed ≤12000 rpm (mechanical) ≤6000 rpm (electric) Steps per turn ≤4096 / 12 bit Initializing time typ. 170 ms after power on manufacter SKU BMMV 58K DeviceNet
Starting torque ≤2 Ncm (+20 °C, IP 65) ≤2.5 Ncm (+20 °C, IP 67) Approval UL approval / E217823 Angular accuracy ±0.5 ° Function Multiturn Initializing time ≤250 ms after power on Admitted shaft load ≤40 N axial ≤80 N radial Programmable parameters Steps per revolution Number of revolutions Preset Scaling Rotating direction Shaft type ø10 x 20 mm, solid shaft with flat (clampin
Code Binary Status indicator DUO-LED integrated in bus cover Admitted shaft load ≤120 N axial (combined) ≤280 N radial (combined) ≤270 N axial (concentrated load) Interference immunity DIN EN 61000-6-2 Connection Bus cover Shaft type ø10 mm solid shaft (clamping flange) Code sequence CW default, programmable Emitted interference DIN EN 61000-6-3 Function Multiturn Weight approx
manufacter SKU BMMV 58K Profibus-DP - MAGRES hermetic Shaft type ø10 mm solid shaft (clamping flange) Device adress Rotary switch in housing Sensing method Magnetic Admitted shaft load ≤120 N axial (combined) ≤280 N radial (combined) ≤270 N axial (concentrated load) Number of turns ≤65536 / 16 bit Resistance DIN EN 60068-2-6 Vibration 30 g, 10-2000 Hz DIN EN 60068-2-27 Shock 500 g, 6 ms
Voltage supply 5 VDC ±10 % 10...30 VDC manufacter SKU BMMV 58K SSI - MAGRES Emitted interference DIN EN 61000-6-3 Angular accuracy ±0.5 ° Inputs SSI clock: Linereceiver RS422 Zero setting input Number of turns 8192 / 13 bit Size (flange) ø58 mm Initializing time typ. 170 ms after power on Approval UL approval / E217823 Repeatability 0.3 ° Resistance DIN EN 60068-2-6 Vibration
Code Gray or binary Absolute accuracy ±1 ° Consumption typ. 100 mA (5 VDC, w/o load) 50 mA (24 VDC, w/o load) Output stages SSI data: linedriver RS485 Operating torque typ. 0.031 Nm Operating speed ≤6000 rpm Shaft type ø10 mm solid shaft (clamping flange) Interference immunity DIN EN 61000-6-2 Number of turns 8192 / 13 bit Code sequence CW: ascending values with clockwise sense o
Operating temperature -40...+85 °C Relative humidity 95 % Emitted interference DIN EN 61000-6-4 Connection Connector M12, 5-pin Connector M12, 8-pin Cable 2 m Weight approx. 300 g Response time Programmable parameters Measuring range teachable Reverse polarity protection Yes Operating torque typ. 0.0023 Nm Code sequence CW: ascending values with clockwise sense of rotation; looking at fla
Emitted interference DIN EN 61000-6-3 Function Multiturn Size (flange) ø58 mm Weight approx. 300 g Consumption w/o load ≤80 mA (24 VDC) Shaft type ø6 x 10 mm, solid shaft with flat (synchro flange) Code sequence CW default, programmable Resistance DIN EN 60068-2-6 Vibration 30 g, 10-2000 Hz DIN EN 60068-2-27 Shock 500 g, 6 ms Materials Housing: steel zinc-coated Flange: aluminiu
Code sequence CW default, programmable Initializing time typ. 500 ms after power on Number of turns ≤262144 / 18 bit Interface CANopen® Relative humidity 95 % Emitted interference DIN EN 61000-6-3 Consumption typ. 100 mA (24 VDC, w/o load) Code Binary Weight approx. 300 g Operating temperature -20...+65 °C Profile conformity CiA 301 V4.1, CiA 305 V1.0, CiA 406 V3.2 (Multi-Sensor
Materials Housing: aluminium Flange: aluminium Approval UL approval / E217823 Weight approx. 300 g Interference immunity DIN EN 61000-6-2 Sensing method Magnetic Code sequence CW default, programmable Code Binary Operating speed ≤12000 rpm (mechanical) ≤6000 rpm (electric) manufacter SKU BMMV 58S DeviceNet - MAGRES Operating torque typ. 0.023 Nm Admitted shaft load ≤10 N axial &
Code Binary Size (flange) ø58 mm Operating temperature -40...+85 °C (see general informations) Emitted interference DIN EN 61000-6-3 Status indicator DUO-LED integrated in bus cover Programmable parameters Steps per revolution Number of revolutions Preset Scaling Rotating direction Connection Bus cover Repeatability 0.3 ° Diagnostic functions Multiturn sensing Position error Shaft ty
Weight approx. 300 g Number of turns 8192 / 13 bit Starting torque ≤2 Ncm (+20 °C, IP 65) ≤2.5 Ncm (+20 °C, IP 67) Size (flange) ø58 mm Shaft type ø6 x 10 mm, solid shaft with flat (synchro flange) Function Multiturn Operating speed ≤6000 rpm Materials Housing: steel zinc-coated Flange: aluminium Solid shaft: stainless steel Connection Connector M12, 8-pin Connector M23, 1
Sensing method Magnetic Steps per turn 4096 / 12 bit Code sequence CW: ascending values with clockwise sense of rotation; looking at flange Initializing time typ. 70 ms after power on Materials Housing: steel Flange: aluminium Weight approx. 60 g Approval UL approval / E217823 Size (flange) ø30 mm Emitted interference DIN EN 61000-6-3 Function Singleturn Relative humidity 95 %
Materials Housing: steel Flange: aluminium Connection Connector M12, 5-pin Cable Resistance DIN EN 60068-2-6 Vibration 30 g, 10-2000 Hz DIN EN 60068-2-27 Shock 500 g, 6 ms Profile conformity CANopen® CiA DSP 301 4.01, DSP 305 V1.0, DSP 406 V3.0 Operating temperature -20...+85 °C Initializing time typ. 170 ms after power on Code Binary Code sequence CW default, programmable manufacter SKU BMSH 4
Sensing method Magnetic manufacter SKU BMSH 42 DeviceNet - MAGRES Operating torque typ. 0.0093 Nm Interference immunity DIN EN 61000-6-2 Profile conformity Device Profile Encoder V 1.0 Approval UL approval / E217823 Shaft type ø12 mm (blind hollow shaft) Connection Connector M12, 5-pin Cable Size (flange) ø42 mm Steps per turn ≤4096 / 12 bit Operating temperature -20...+
Steps per turn 512 / 9 bit Operating torque typ. 0.0093 Nm Initializing time typ. 170 ms after power on Interface 9 parallel outputs Protection DIN EN 60529 IP 65 Consumption typ. 100 mA (24 VDC, w/o load) Shaft type ø12 mm (blind hollow shaft) Code sequence CW: ascending values with clockwise sense of rotation; looking at flange Interference immunity DIN EN 61000-6-2 Voltage supply 5
Consumption typ. 100 mA (5 VDC, w/o load) 50 mA (24 VDC, w/o load) Weight approx. 120 g Initializing time typ. 170 ms after power on Inputs SSI clock Zero setting input Interface SSI Shaft type ø12 mm (blind hollow shaft) Protection DIN EN 60529 IP 65 Output stages SSI data: linedriver RS485 Voltage supply 5 VDC ±10 % 10...30 VDC Relative humidity 95 % Size (flange) ø42
Menu
Mail Us
enquiry@onstocktrading.com