Specification: Part Number AFM60A-TGPM262144 Clock frequency: 2 MHz Storage temperature range: -40 °C ... 100 °C, without package Error limits: ± 0.03 ° Code type: Gray Resolution: 18 bit x 12 bit Initialization time: 50 ms CW/CCW (counting sequence when turning): L-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) Bearing lifetime: 3.0 x 10^9 revolutions Permissible relative humidity: 90 % (condens
Specification: Part Number AFM60A-THPC262144 MTTFd: mean time to dangerous failure: 250 a (EN ISO 13849-1) Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.05 mm Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.01 mm Power consumption: 0.5 W (without load) Code sequence: CW/CCW, parameter adjustable Type of mounting shaft: Through hollow shaft Maximum operating speed: 9,000 /min Mass: 0.
Specification: Part Number 1038906 Type of mounting shaft: Through hollow shaft Initialization time: 50 ms Repeat accuracy: 0.002 ° Moment of inertia of the rotor: 40 gcm² Power consumption: 0.5 W (without load) MTTFd: mean time to dangerous failure: 250 a (EN ISO 13849-1) Storage temperature range: -40 °C ... 100 °C, without package Resistance to shocks: 60 g, 6 ms (according to EN 60068-2-27) Measur
Specification: Part Number AFM60B-BBPK032768 Repeat accuracy: 0.002 ° EMC: (according to EN 61000-6-2 and EN 61000-6-3) Operating voltage range: 4.5 V DC ... 32 V DC Enclosure rating: IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing side Measuring step: 0.01 ° Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Start up torque: 0.8 Ncm (20
Specification: Part Number 1050279 Shaft diameter: 10 mm Initialization time: 50 ms Power consumption: 0.5 W (without load) Resistance to vibration: 30 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Moment of inertia of the rotor: 40 gcm² Resistance to shocks: 70 g (according to EN 60068-2-27) Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 mm Storage temperature range: -40 °C ... 100 °C, w
Specification: Part Number 1050280 Initialization time: 50 ms Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm Max. number of steps per revolution: 8,192 Measuring step deviation: ± 0.01 ° Bearing lifetime: 3.0 x 10^9 revolutions Max. number of revolutions: 4,096 Resistance to vibration: 30 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) CW/CCW (counting sequence when turning): L-active (L
Specification: Part Number 1054980 Power consumption: 0.5 W (without load) Moment of inertia of the rotor: 40 gcm² Bearing lifetime: 3.0 x 10^9 revolutions Start up torque: 0.8 Ncm (20 °C) CW/CCW (counting sequence when turning): L-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) Maximum operating speed: 6,000 /min MTTFd: mean time to dangerous failure: 250 a (EN ISO 13849-1) Resolution: 13 bit x 12 bit
Specification: Part Number 1052197 Maximum operating speed: 6,000 /min Initialization time: 50 ms Repeat accuracy: 0.002 ° Storage temperature range: -40 °C ... 100 °C, without package Moment of inertia of the rotor: 40 gcm² Max. number of revolutions: 4,096 Shaft diameter: 12 mm Clock frequency: 2 MHz Mechanical interface: Blind hollow shaft Error limits: ± 0.05 ° Measuring step deviation:
Specification: Part Number 1051391 Error limits: ± 0.05 ° Maximum operating speed: 6,000 /min Mechanical interface: Blind hollow shaft Shaft diameter: 12 mm Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 mm Resolution power: 4,096 x 4,096 Permissible relative humidity: 90 % (condensation of the optical scanning not permitted)
Specification: Part Number 1038905 MTTFd: mean time to dangerous failure: 250 a (EN ISO 13849-1) Error limits: ± 0.05 ° Clock frequency: 2 MHz Resolution power: 32,768 x 4,096 Repeat accuracy: 0.002 ° Operating torque: 0.6 Ncm (20 °C) Interface signals: Clock +, Clock -, Data +, Data- Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 mm Operating voltage range: 4.5 V DC ... 32 V DC Meas
Specification: Part Number 1051112 Repeat accuracy: 0.002 ° Mass: 0.2 kg Max. angular acceleration: 500,000 rad/s² Operating voltage range: 4.5 V DC ... 32 V DC Initialization time: 50 ms Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 mm CW/CCW (counting sequence when turning): L-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm
Specification: Part Number 1051116 Moment of inertia of the rotor: 40 gcm² Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm MTTFd: mean time to dangerous failure: 250 a (EN ISO 13849-1) Resolution: 15 bit x 12 bit Error limits: ± 0.05 ° Measuring step: 0.01 ° Mechanical interface: Blind hollow shaft CW/CCW (counting sequence when turning): L-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us
Specification: Part Number 1053036 Initialization time: 50 ms Max. number of revolutions: 4,096 EMC: (according to EN 61000-6-2 and EN 61000-6-3) Repeat accuracy: 0.002 ° Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Maximum operating speed: 9,000 /min Start up torque: 0.5 Ncm (20 °C) SET (electronic adjustment): H-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us
Specification: Part Number 1037657 Resolution power: 32,768 x 4,096 Mass: 0.26 kg Power consumption: 0.5 W (without load) Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Electrical interface: Connector M23, 12-pin, radial Max. angular acceleration: 500,000 rad/s² Measuring step deviation: ± 0.01 ° Operating voltage range: 4.5 V DC ... 32 V DC Bearing lifetime: 3.
Specification: Part Number 1037869 Measuring step: 0.01 ° Max. number of revolutions: 4,096 Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Bearing lifetime: 3.0 x 10^9 revolutions Mechanical interface: Solid shaft, Servo flange Clock frequency: 2 MHz Moment of inertia of the rotor: 6.2 gcm² Working temperature range: -30 °C ... 100 °C SET (electronic adjustment
Specification: Part Number 1053037 Resistance to shocks: 70 g (according to EN 60068-2-27) Interface signals: Clock +, Clock -, Data +, Data- Permissible Load capacity of shaft: 40 N (axial), 80 N (radial) EMC: (according to EN 61000-6-2 and EN 61000-6-3) Operating torque: 0.3 Ncm (20 °C) Max. number of steps per revolution: 16,384 Measuring step deviation: ± 0.01 ° Error limits: ± 0.05 ° MTTFd: mean
Specification: Part Number 1037439 Initialization time: 50 ms Resistance to shocks: 70 g (according to EN 60068-2-27) Resistance to vibration: 30 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Max. number of revolutions: 4,096 Resolution: 15 bit x 12 bit Operating torque: 0.3 Ncm (20 °C) Working temperature range: -30 °C ... 100 °C Storage temperature range: -40 °C ... 100 °C, without package Error
Specification: Part Number 1037870 Storage temperature range: -40 °C ... 100 °C, without package Electrical interface: Cable, 8-pin, universal, 1.5 m EMC: (according to EN 61000-6-2 and EN 61000-6-3) Mechanical interface: Solid shaft, Servo flange Permissible Load capacity of shaft: 40 N (axial), 80 N (radial) Enclosure rating: IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing sid
Specification: Part Number 1037864 Moment of inertia of the rotor: 6.2 gcm² Storage temperature range: -40 °C ... 100 °C, without package Working temperature range: -30 °C ... 100 °C Resolution power: 8,192 x 4,096 Measuring step: 0.01 ° Electrical interface: Cable, 8-pin, universal, 1.5 m Power consumption: 0.5 W (without load) Permissible relative humidity: 90 % (condensation of the optical scanning n
Specification: Part Number 1037658 Storage temperature range: -40 °C ... 100 °C, without package Working temperature range: -30 °C ... 100 °C Electrical interface: Cable, 8-pin, universal, 1.5 m Interface signals: Clock +, Clock -, Data +, Data- Mechanical interface: Solid shaft, Servo flange Moment of inertia of the rotor: 6.2 gcm² Resolution power: 32,768 x 4,096 Measuring step: 0.01 ° Permissible
Specification: Part Number 1037659 Storage temperature range: -40 °C ... 100 °C, without package Moment of inertia of the rotor: 6.2 gcm² Permissible Load capacity of shaft: 40 N (axial), 80 N (radial) Measuring step: 0.01 ° Clock frequency: 2 MHz Initialization time: 50 ms CW/CCW (counting sequence when turning): L-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) Resolution: 15 bit x 12 bit Resista
Specification: Part Number 1053154 Start up torque: 0.5 Ncm (20 °C) Moment of inertia of the rotor: 6.2 gcm² SET (electronic adjustment): H-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Maximum operating speed: 9,000 /min CW/CCW (counting sequence when turning): L-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) Power
Specification: Part Number 1037660 Max. number of revolutions: 4,096 Max. angular acceleration: 500,000 rad/s² Maximum operating speed: 9,000 /min Resistance to shocks: 70 g (according to EN 60068-2-27) Electrical interface: Cable, 8-pin, universal, 5 m Storage temperature range: -40 °C ... 100 °C, without package Initialization time: 50 ms Resistance to vibration: 30 g, 10 Hz ... 2,000 Hz (according to
Specification: Part Number 1053515 Bearing lifetime: 3.0 x 10^9 revolutions SET (electronic adjustment): H-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) Operating voltage range: 4.5 V DC ... 32 V DC Error limits: ± 0.05 ° Measuring step deviation: ± 0.01 ° Operating torque: 0.3 Ncm (20 °C) Mass: 0.26 kg Resolution power: 4,096 x 4,096 Resolution: 12 bit x 12 bit Maximum operating speed: 9,000
Specification: Part Number 1037515 Permissible Load capacity of shaft: 40 N (axial), 80 N (radial) Clock frequency: 2 MHz SET (electronic adjustment): H-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) Resolution: 15 bit x 12 bit Initialization time: 50 ms Repeat accuracy: 0.002 ° Resistance to vibration: 30 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Resolution power: 32,768 x 4,096 Shaft diamet
Specification: Part Number 1037516 MTTFd: mean time to dangerous failure: 250 a (EN ISO 13849-1) Initialization time: 50 ms Resolution: 15 bit x 12 bit CW/CCW (counting sequence when turning): L-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) Electrical interface: Cable, 8-pin, universal, 3 m Operating voltage range: 4.5 V DC ... 32 V DC Mechanical interface: Solid shaft, Servo flange Max. angular acceler
Specification: Part Number 1037517 Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Resistance to vibration: 30 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Electrical interface: Cable, 8-pin, universal, 5 m Operating voltage range: 4.5 V DC ... 32 V DC Max. angular acceleration: 500,000 rad/s² Power consumption: 0.5 W (without load) Bearing lifetime: 3.0 x 10^9 revol
Specification: Part Number 1053516 Measuring step: 90 ° elektrisch / Strichzahl Start up torque: 0.5 Ncm (20 °C) Maximum output frequency: 600 kHz MTTFd: mean time to dangerous failure: 250 a (EN ISO 13849-1) Operating voltage range: 4.5 V DC ... 32 V DC EMC: (according to EN 61000-6-2 and EN 61000-6-3) Max. angular acceleration: 500,000 rad/s² CW/CCW (counting sequence when turning): L-active (L &;8801;
Specification: Part Number 1037661 Measuring step: 0.01 ° Repeat accuracy: 0.002 ° Error limits: ± 0.05 ° EMC: (according to EN 61000-6-2 and EN 61000-6-3) Operating voltage range: 4.5 V DC ... 32 V DC Max. angular acceleration: 500,000 rad/s² Resolution power: 32,768 x 4,096 Moment of inertia of the rotor: 6.2 gcm² Shaft diameter: 10 mm Max. number of steps per revolution: 32,768 Maximum ope