SICK - Pressure sensor PBT

Image
Part Number
Description
Specification: Part Number 6038632 Process connection: G ¼ female Vibration load: 10 g according to IEC 60068-2-6 (vibration under resonance), 20 g optional Relative humidity: 45 % ... 75 % Adjustment accuracy of zero signal: ≤ 0.5 % of span typ., ≤ 0.8 % of span max. (with non-linerarity 0.5 %) Service life: Minimum 100 Mio. life cycles Isolation voltage: 500 V DC CE-conformity: Pressure equipment directiv
Specification: Part Number 6042038 Enclosure rating: IP 67 Medium: Liquid and gaseous media Compound pressure: -1 bar ... 0 bar up to -1 bar ... +24 bar Accuracy: ≤ ± 0.5 % of span (with non-linearity 0.25 %), ≤ ± 0,6 % of Span (with non-linearity 0.25 % and with signal output 0 ... 5 V), ≤ ± 1,0 % of Span (with non-linearity 0.5 %), (Including non-linearity, hysteresis, zero point and full scale error (correspond
Specification: Part Number 6042663 Relative humidity: 45 % ... 75 % Medium: Liquid and gaseous media Weight sensor: Ca. 80 g Compound pressure: -1 bar ... 0 bar up to -1 bar ... +24 bar Connection type: Round connector M12 x 1, 4-pin, IP 67 Vibration load: 10 g according to IEC 60068-2-6 (vibration under resonance), 20 g optional Internal transmission fluid: Silicone oil (only with pressure ranges < 0 bar ... 10
Specification: Part Number 6041553 Service life: Minimum 100 Mio. life cycles Long-term drift/one-year stability: &le; 0.1 % of span according to IEC 61298-2 CE-conformity: Pressure equipment directive: 97/23/EC, EMC directive: 2004/108/EC, EN 61 326-2-3 Wetted parts: Pressure connection: stainless steel 316L, Pressure sensor: stainless steel 316L (for measurement ranges from 0 bar ... 10 bar rel stainless steel 13-8 PH) S
Specification: Part Number 6038656 Pressure port: Standard Output signal: 4 mA ... 20 mA Weight sensor: Ca. 80 g Non-linearity: &le; ± 0.5 % ((Best Fit Straight Line, BFSL) according to IEC 61298-2) Rated temperature range: 0 °C ... +80 °C Storage temperature: -20 °C ... +80 °C Non-repeatability: &le; 0.1 % of span Medium: Liquid and gaseous media Measuring range: 0 bar ... 400 bar Process temperat
Specification: Part Number 6038657 Rated temperature range: 0 °C ... +80 °C Isolation voltage: 500 V DC CE-conformity: Pressure equipment directive: 97/23/EC, EMC directive: 2004/108/EC, EN 61 326-2-3 Relative humidity: 45 % ... 75 % Pressure type: Gauge pressure Process connection: G ¼ female Ambient temperature: 0 °C ... +80 °C Wetted parts: Pressure connection: stainless steel 316L, Pressure sensor: st
Specification: Part Number 6038659 Relative humidity: 45 % ... 75 % Process connection: G ¼ female Housing material: Stainless steel 316L Reference conditions: Reference conditions: According to IEC 61298-1 Rated temperature range: 0 °C ... +80 °C Signal noise: &le; 0.3 % of span Accuracy: &le; ± 0,6 % of Span (with non-linearity 0.25 % and with signal output 0 ... 5 V), &le; ± 1 % of span (with non-linearity
Specification: Part Number 6044789 Long-term drift/one-year stability: &le; 0.1 % of span according to IEC 61298-2 Wetted parts: Pressure connection: stainless steel 316L, Pressure sensor: stainless steel 316L (for measurement ranges from 0 bar ... 10 bar rel stainless steel 13-8 PH) Protection class III: + Weight sensor: Ca. 80 g Pressure type: Gauge pressure Absolute pressure: 0 bar ... 1 bar up to 0 bar ... 25 bar
Specification: Part Number 6040921 Pressure type: Gauge pressure Relative humidity: 45 % ... 75 % Electrical safety: Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 32 V DC, 36 V DC with 4 mA ... 20 mA, Reverse polarity protection: L+ towards M CE-conformity: Pressure equipment directive: 97/23/EC, EMC directive: 2004/108/EC, EN 61 326-2-3 Measuring range: 0 bar ... 4 bar Storage
Specification: Part Number 6038633 Weight sensor: Ca. 80 g Internal transmission fluid: Silicone oil (only with pressure ranges < 0 bar ... 10 bar and &le; 0 bar abs ... 25 bar abs) Signal noise: &le; 0.3 % of span Gauge pressure: 0 bar ... 1 bar up to bar ... 600 bar Enclosure rating: IP 67 Protection class III: + Process temperature: 0 °C ... +80 °C Isolation voltage: 500 V DC Long-term drift/one-year
Specification: Part Number 6038635 Process temperature: 0 °C ... +80 °C Seal: NBR Long-term drift/one-year stability: &le; 0.1 % of span according to IEC 61298-2 Process connection: G ¼ A according to DIN 3852-E Adjustment accuracy of zero signal: &le; 0.5 % of span typ., &le; 0.8 % of span max. (with non-linerarity 0.5 %) Absolute pressure: 0 bar ... 1 bar up to 0 bar ... 25 bar Relative humidity: 45 % ... 75
Specification: Part Number 6038636 Response time: < 4 ms Shock load: 500 g according to IEC 60068-2-27 (mechanical shock) Process temperature: 0 °C ... +80 °C Compound pressure: -1 bar ... 0 bar up to -1 bar ... +24 bar Seal: Without seal Storage temperature: -20 °C ... +80 °C Service life: Minimum 100 Mio. life cycles Accuracy: &le; ± 0,6 % of Span (with non-linearity 0.25 % and with signal output 0 ...
Specification: Part Number 6049311 CE-conformity: Pressure equipment directive: 97/23/EC, EMC directive: 2004/108/EC, EN 61 326-2-3 Adjustment accuracy of zero signal: &le; 0.5 % of span typ., &le; 0.8 % of span max. (with non-linerarity 0.5 %) Vibration load: 10 g according to IEC 60068-2-6 (vibration under resonance), 20 g optional Reference conditions: Reference conditions: According to IEC 61298-1 Power consumption: M
Specification: Part Number 6042824 Shock load: 500 g according to IEC 60068-2-27 (mechanical shock) Long-term drift/one-year stability: &le; 0.1 % of span according to IEC 61298-2 Response time: < 4 ms Reference conditions: Reference conditions: According to IEC 61298-1 Adjustment accuracy of zero signal: &le; 0.5 % of span typ., &le; 0.8 % of span max. (with non-linerarity 0.5 %) Connection type: Round connector M12
Specification: Part Number 6039111 Adjustment accuracy of zero signal: &le; 0.15 % of span typ., &le; 0.4 % of span max. (with non-linerarity 0.25 %) Reference conditions: Reference conditions: According to IEC 61298-1 Protection class III: + Electrical safety: Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 32 V DC, 36 V DC with 4 mA ... 20 mA, Reverse polarity protection: L+ towards
Specification: Part Number 6043580 Connection type: L-connector acc. to DIN 175301-803 A, IP 65 Ambient temperature: 0 °C ... +80 °C Process connection: G ¼ A according to DIN 3852-E Pressure port: Standard Power consumption: Max. 8 mA for voltage output signal, Signal current (max. 25 mA) for current output Service life: Minimum 100 Mio. life cycles Shock load: 500 g according to IEC 60068-2-27 (mechanical sho
Specification: Part Number 6038660 Weight sensor: Ca. 80 g Protection class III: + Process connection: G ¼ A according to DIN 3852-E Gauge pressure: 0 bar ... 1 bar up to bar ... 600 bar Isolation voltage: 500 V DC Relative humidity: 45 % ... 75 % Power consumption: Max. 8 mA for voltage output signal, Signal current (max. 25 mA) for current output Reference conditions: Reference conditions: According to IEC
Specification: Part Number 6038661 Weight sensor: Ca. 80 g Response time: < 4 ms Ambient temperature: 0 °C ... +80 °C CE-conformity: Pressure equipment directive: 97/23/EC, EMC directive: 2004/108/EC, EN 61 326-2-3 Signal noise: &le; 0.3 % of span Relative humidity: 45 % ... 75 % Seal: Without seal Process connection: G ¼ female Reference conditions: Reference conditions: According to IEC 61298-1 Ab
Specification: Part Number 6052069 Compound pressure: -1 bar ... 0 bar up to -1 bar ... +24 bar Internal transmission fluid: Silicone oil (only with pressure ranges < 0 bar ... 10 bar and &le; 0 bar abs ... 25 bar abs) Relative humidity: 45 % ... 75 % Isolation voltage: 500 V DC Shock load: 500 g according to IEC 60068-2-27 (mechanical shock) Medium: Liquid and gaseous media Accuracy: &le; ± 0,6 % of Span (with
Specification: Part Number 6041050 Adjustment accuracy of zero signal: &le; 0.5 % of span typ., &le; 0.8 % of span max. (with non-linerarity 0.5 %) Ambient temperature: 0 °C ... +80 °C Long-term drift/one-year stability: &le; 0.1 % of span according to IEC 61298-2 Output signal: 4 mA ... 20 mA Pressure type: Gauge pressure Housing material: Stainless steel 316L Power consumption: Max. 8 mA for voltage output sig
Specification: Part Number 6039105 Connection type: Round connector M12 x 1, 4-pin, IP 67 Seal: NBR Protection class III: + Reference conditions: Reference conditions: According to IEC 61298-1 Weight sensor: Ca. 80 g Relative humidity: 45 % ... 75 % Medium: Liquid and gaseous media Pressure port: Standard Electrical safety: Short-circuit protection: QA towards M, Protection class: III, Overvoltage protecti
Specification: Part Number 6041442 Power consumption: Max. 8 mA for voltage output signal, Signal current (max. 25 mA) for current output Adjustment accuracy of zero signal: &le; 0.5 % of span typ., &le; 0.8 % of span max. (with non-linerarity 0.5 %) Measuring range: 0 bar ... 6 bar Medium: Liquid and gaseous media Storage temperature: -30 °C ... +100 °C Electrical safety: Short-circuit protection: QA towards M, Pro
Specification: Part Number 6041707 Measuring range: 0 bar ... 6 bar Non-repeatability: &le; 0.1 % of span Long-term drift/one-year stability: &le; 0.1 % of span according to IEC 61298-2 Storage temperature: -20 °C ... +80 °C Connection type: L-connector acc. to DIN 175301-803 A, IP 65 Ambient temperature: 0 °C ... +80 °C Shock load: 500 g according to IEC 60068-2-27 (mechanical shock) Relative humidity: 45
Specification: Part Number 6041617 Measuring range: 0 bar ... 6 bar Output signal: 4 mA ... 20 mA Rated temperature range: 0 °C ... +80 °C Isolation voltage: 500 V DC Ambient temperature: 0 °C ... +80 °C Adjustment accuracy of zero signal: &le; 0.5 % of span typ., &le; 0.8 % of span max. (with non-linerarity 0.5 %) Pressure port: Standard Enclosure rating: IP 67 Weight sensor: Ca. 80 g Internal tran
Specification: Part Number 6039039 Connection type: Round connector M12 x 1, 4-pin, IP 67 Ambient temperature: 0 °C ... +80 °C Wetted parts: Pressure connection: stainless steel 316L, Pressure sensor: stainless steel 316L (for measurement ranges from 0 bar ... 10 bar rel stainless steel 13-8 PH) Signal noise: &le; 0.3 % of span Weight sensor: Ca. 80 g Service life: Minimum 100 Mio. life cycles Protection class II
Specification: Part Number 6045121 Output signal: 4 mA ... 20 mA Compound pressure: -1 bar ... 0 bar up to -1 bar ... +24 bar Process temperature: 0 °C ... +80 °C Vibration load: 10 g according to IEC 60068-2-6 (vibration under resonance), 20 g optional CE-conformity: Pressure equipment directive: 97/23/EC, EMC directive: 2004/108/EC, EN 61 326-2-3 Medium: Liquid and gaseous media Shock load: 500 g according to
Specification: Part Number 6048596 Response time: < 4 ms Signal noise: &le; 0.3 % of span Rated temperature range: 0 °C ... +80 °C Adjustment accuracy of zero signal: &le; 0.5 % of span typ., &le; 0.8 % of span max. (with non-linerarity 0.5 %) Pressure port: Standard Accuracy: &le; ± 0,6 % of Span (with non-linearity 0.25 % and with signal output 0 ... 5 V), &le; ± 1 % of span (with non-linearity 0.25 %), &le; ±
Specification: Part Number 6044018 Protection class III: + Seal: NBR Wetted parts: Pressure connection: stainless steel 316L, Pressure sensor: stainless steel 316L (for measurement ranges from 0 bar ... 10 bar rel stainless steel 13-8 PH) Enclosure rating: IP 65 Process connection: G ½ A according to DIN 3852-E Non-linearity: &le; ± 0.5 % ((Best Fit Straight Line, BFSL) according to IEC 61298-2) Hysteresis: &le;
Specification: Part Number 6044393 Non-repeatability: &le; 0.1 % of span Compound pressure: -1 bar ... 0 bar up to -1 bar ... +24 bar Shock load: 500 g according to IEC 60068-2-27 (mechanical shock) Internal transmission fluid: Silicone oil (only with pressure ranges < 0 bar ... 10 bar and &le; 0 bar abs ... 25 bar abs) Protection class III: + Seal: NBR Response time: < 4 ms Medium: Liquid and gaseous media
Specification: Part Number 6038962 Shock load: 500 g according to IEC 60068-2-27 (mechanical shock) Protection class III: + Process temperature: -30 °C ... +100 °C Service life: Minimum 100 Mio. life cycles Rated temperature range: 0 °C ... +80 °C Response time: < 4 ms Electrical safety: Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 32 V DC, 36 V DC with 4 mA ... 20 mA
Menu
Mail Us
enquiry@onstocktrading.com