Specification: Part Number 6041519 Ambient temperature: 0 °C ... +80 °C Non-linearity: ≤ ± 0.5 % ((Best Fit Straight Line, BFSL) according to IEC 61298-2) Gauge pressure: 0 bar ... 1 bar up to bar ... 600 bar Isolation voltage: 500 V DC Seal: NBR Process temperature: 0 °C ... +80 °C Compound pressure: -1 bar ... 0 bar up to -1 bar ... +24 bar Shock load: 500 g according to IEC 60068-2-27 (mechanical s
Specification: Part Number 6039769 Response time: < 4 ms Gauge pressure: 0 bar ... 1 bar up to bar ... 600 bar Non-linearity: &le; ± 0.5 % ((Best Fit Straight Line, BFSL) according to IEC 61298-2) Protection class III: + Enclosure rating: IP 67 Process temperature: 0 °C ... +80 °C Non-repeatability: &le; 0.1 % of span Adjustment accuracy of zero signal: &le; 0.5 % of span typ., &le; 0.8 % of span max. (wi
Specification: Part Number 6042297 Non-linearity: &le; ± 0.5 % ((Best Fit Straight Line, BFSL) according to IEC 61298-2) Signal noise: &le; 0.3 % of span Housing material: Stainless steel 316L Reference conditions: Reference conditions: According to IEC 61298-1 Gauge pressure: 0 bar ... 1 bar up to bar ... 600 bar Absolute pressure: 0 bar ... 1 bar up to 0 bar ... 25 bar Connection type: L-connector acc. to DIN
Specification: Part Number 6048176 Relative humidity: 45 % ... 75 % Signal noise: &le; 0.3 % of span Absolute pressure: 0 bar ... 1 bar up to 0 bar ... 25 bar Shock load: 500 g according to IEC 60068-2-27 (mechanical shock) Rated temperature range: 0 °C ... +80 °C Long-term drift/one-year stability: &le; 0.1 % of span according to IEC 61298-2 Electrical safety: Short-circuit protection: QA towards M, Protection
Specification: Part Number 6041704 Weight sensor: Ca. 80 g Vibration load: 10 g according to IEC 60068-2-6 (vibration under resonance), 20 g optional Internal transmission fluid: Silicone oil (only with pressure ranges < 0 bar ... 10 bar and &le; 0 bar abs ... 25 bar abs) Wetted parts: Pressure connection: stainless steel 316L, Pressure sensor: stainless steel 316L (for measurement ranges from 0 bar ... 10 bar rel stainless
Specification: Part Number 6038642 Ambient temperature: 0 °C ... +80 °C Pressure type: Gauge pressure Accuracy: &le; ± 0,6 % of Span (with non-linearity 0.25 % and with signal output 0 ... 5 V), &le; ± 1 % of span (with non-linearity 0.25 %), &le; ± 1,0 % of Span (with non-linearity 0.5 %), (Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement according to IEC 61298-2))
Specification: Part Number 6038641 Rated temperature range: 0 °C ... +80 °C Signal noise: &le; 0.3 % of span Response time: < 4 ms Adjustment accuracy of zero signal: &le; 0.5 % of span typ., &le; 0.8 % of span max. (with non-linerarity 0.5 %) Enclosure rating: IP 67 Protection class III: + Relative humidity: 45 % ... 75 % Long-term drift/one-year stability: &le; 0.1 % of span according to IEC 61298-2 Am
Specification: Part Number 6038646 Shock load: 500 g according to IEC 60068-2-27 (mechanical shock) Gauge pressure: 0 bar ... 1 bar up to bar ... 600 bar Storage temperature: -20 °C ... +80 °C Output signal: 0...10 V, 3-wire Power consumption: Max. 8 mA for voltage output signal, Signal current (max. 25 mA) for current output Rated temperature range: 0 °C ... +80 °C Compound pressure: -1 bar ... 0 bar up to -
Specification: Part Number 6042520 Pressure type: Gauge pressure Shock load: 500 g according to IEC 60068-2-27 (mechanical shock) Connection type: Round connector M12 x 1, 4-pin, IP 67 Accuracy: &le; ± 0,6 % of Span (with non-linearity 0.25 % and with signal output 0 ... 5 V), &le; ± 1 % of span (with non-linearity 0.25 %), &le; ± 1,0 % of Span (with non-linearity 0.5 %), (Including non-linearity, hysteresis, zero point an
Specification: Part Number 6038648 Pressure port: Standard Process connection: G ¼ A according to DIN 3852-E Non-repeatability: &le; 0.1 % of span Hysteresis: &le; 0.16 % of span Process temperature: 0 °C ... +80 °C Connection type: Round connector M12 x 1, 4-pin, IP 67 CE-conformity: Pressure equipment directive: 97/23/EC, EMC directive: 2004/108/EC, EN 61 326-2-3 Enclosure rating: IP 67 Protection clas
Specification: Part Number 6038650 Adjustment accuracy of zero signal: &le; 0.5 % of span typ., &le; 0.8 % of span max. (with non-linerarity 0.5 %) Weight sensor: Ca. 80 g Shock load: 500 g according to IEC 60068-2-27 (mechanical shock) Pressure port: Standard Process connection: G ¼ A according to DIN 3852-E Ambient temperature: 0 °C ... +80 °C Internal transmission fluid: Silicone oil (only with pressure rang
Specification: Part Number 6038649 Absolute pressure: 0 bar ... 1 bar up to 0 bar ... 25 bar Response time: < 4 ms Reference conditions: Reference conditions: According to IEC 61298-1 Medium: Liquid and gaseous media Process connection: G ¼ female Adjustment accuracy of zero signal: &le; 0.5 % of span typ., &le; 0.8 % of span max. (with non-linerarity 0.5 %) Compound pressure: -1 bar ... 0 bar up to -1 bar ... +
Specification: Part Number 6038651 Pressure port: Standard Process connection: G ¼ female Accuracy: &le; ± 0,6 % of Span (with non-linearity 0.25 % and with signal output 0 ... 5 V), &le; ± 1 % of span (with non-linearity 0.25 %), &le; ± 1,0 % of Span (with non-linearity 0.5 %), (Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement according to IEC 61298-2)) Storage temp
Specification: Part Number 6048851 Service life: Minimum 100 Mio. life cycles Vibration load: 10 g according to IEC 60068-2-6 (vibration under resonance), 20 g optional Housing material: Stainless steel 316L Isolation voltage: 500 V DC Protection class III: + Long-term drift/one-year stability: &le; 0.1 % of span according to IEC 61298-2 Process temperature: 0 °C ... +80 °C Measuring range: 0 bar ... 160 bar
Specification: Part Number 6041998 Adjustment accuracy of zero signal: &le; 0.5 % of span typ., &le; 0.8 % of span max. (with non-linerarity 0.5 %) Process connection: G ¼ A according to DIN 3852-E Shock load: 500 g according to IEC 60068-2-27 (mechanical shock) Pressure port: Standard Absolute pressure: 0 bar ... 1 bar up to 0 bar ... 25 bar Process temperature: 0 °C ... +80 °C Protection class III: + Hyste
Specification: Part Number 6038716 Storage temperature: -20 °C ... +80 °C Accuracy: &le; ± 0,6 % of Span (with non-linearity 0.25 % and with signal output 0 ... 5 V), &le; ± 1 % of span (with non-linearity 0.25 %), &le; ± 1,0 % of Span (with non-linearity 0.5 %), (Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement according to IEC 61298-2)) Isolation voltage: 500 V DC
Specification: Part Number 6038627 Process connection: G ¼ A according to DIN 3852-E Wetted parts: Pressure connection: stainless steel 316L, Pressure sensor: stainless steel 316L (for measurement ranges from 0 bar ... 10 bar rel stainless steel 13-8 PH) Vibration load: 10 g according to IEC 60068-2-6 (vibration under resonance), 20 g optional Electrical safety: Short-circuit protection: QA towards M, Protection class: III,
Specification: Part Number 6038717 Long-term drift/one-year stability: &le; 0.1 % of span according to IEC 61298-2 Ambient temperature: 0 °C ... +80 °C Housing material: Stainless steel 316L Vibration load: 10 g according to IEC 60068-2-6 (vibration under resonance), 20 g optional Relative humidity: 45 % ... 75 % Reference conditions: Reference conditions: According to IEC 61298-1 Compound pressure: -1 bar ... 0
Specification: Part Number 6045101 Response time: < 4 ms Shock load: 500 g according to IEC 60068-2-27 (mechanical shock) Output signal: 4 mA ... 20 mA Absolute pressure: 0 bar ... 1 bar up to 0 bar ... 25 bar Internal transmission fluid: Silicone oil (only with pressure ranges < 0 bar ... 10 bar and &le; 0 bar abs ... 25 bar abs) Non-linearity: &le; ± 0.5 % ((Best Fit Straight Line, BFSL) according to IEC 61298-2)
Specification: Part Number 6043421 Adjustment accuracy of zero signal: &le; 0.5 % of span typ., &le; 0.8 % of span max. (with non-linerarity 0.5 %) Gauge pressure: 0 bar ... 1 bar up to bar ... 600 bar Hysteresis: &le; 0.16 % of span Signal noise: &le; 0.3 % of span Ambient temperature: 0 °C ... +80 °C Measuring range: 0 bar ... 1 bar Internal transmission fluid: Silicone oil (only with pressure ranges < 0 bar
Specification: Part Number 6044389 Absolute pressure: 0 bar ... 1 bar up to 0 bar ... 25 bar Internal transmission fluid: Silicone oil (only with pressure ranges < 0 bar ... 10 bar and &le; 0 bar abs ... 25 bar abs) Enclosure rating: IP 65 Hysteresis: &le; 0.16 % of span Non-repeatability: &le; 0.1 % of span Process connection: G ¼ A according to DIN 3852-E Accuracy: &le; ± 0,6 % of Span (with non-linearity 0.2
Specification: Part Number 6039572 Enclosure rating: IP 67 CE-conformity: Pressure equipment directive: 97/23/EC, EMC directive: 2004/108/EC, EN 61 326-2-3 Signal noise: &le; 0.3 % of span Pressure port: Standard Long-term drift/one-year stability: &le; 0.1 % of span according to IEC 61298-2 Connection type: Round connector M12 x 1, 4-pin, IP 67 Wetted parts: Pressure connection: stainless steel 316L, Pressure sen
Specification: Part Number 6041438 Rated temperature range: 0 °C ... +80 °C Shock load: 500 g according to IEC 60068-2-27 (mechanical shock) Response time: < 4 ms Accuracy: &le; ± 0,6 % of Span (with non-linearity 0.25 % and with signal output 0 ... 5 V), &le; ± 1 % of span (with non-linearity 0.25 %), &le; ± 1,0 % of Span (with non-linearity 0.5 %), (Including non-linearity, hysteresis, zero point and full scale error
Specification: Part Number 6038652 Absolute pressure: 0 bar ... 1 bar up to 0 bar ... 25 bar Medium: Liquid and gaseous media Connection type: Round connector M12 x 1, 4-pin, IP 67 Process temperature: 0 °C ... +80 °C Rated temperature range: 0 °C ... +80 °C Electrical safety: Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 32 V DC, 36 V DC with 4 mA ... 20 mA, Reverse polari
Specification: Part Number 6038653 Vibration load: 10 g according to IEC 60068-2-6 (vibration under resonance), 20 g optional Seal: Without seal Connection type: Round connector M12 x 1, 4-pin, IP 67 Reference conditions: Reference conditions: According to IEC 61298-1 Gauge pressure: 0 bar ... 1 bar up to bar ... 600 bar Measuring range: 0 bar ... 250 bar Protection class III: + Housing material: Stainless st
Specification: Part Number 6038655 Storage temperature: -20 °C ... +80 °C Output signal: 0...10 V, 3-wire Rated temperature range: 0 °C ... +80 °C Medium: Liquid and gaseous media Protection class III: + Hysteresis: &le; 0.16 % of span CE-conformity: Pressure equipment directive: 97/23/EC, EMC directive: 2004/108/EC, EN 61 326-2-3 Pressure port: Standard Wetted parts: Pressure connection: stainless ste
Specification: Part Number 6042527 Hysteresis: &le; 0.16 % of span Non-linearity: &le; ± 0.5 % ((Best Fit Straight Line, BFSL) according to IEC 61298-2) Compound pressure: -1 bar ... 0 bar up to -1 bar ... +24 bar Connection type: Round connector M12 x 1, 4-pin, IP 67 Gauge pressure: 0 bar ... 1 bar up to bar ... 600 bar Non-repeatability: &le; 0.1 % of span Ambient temperature: 0 °C ... +80 °C Storage temp
Specification: Part Number 6041098 Measuring range: 0 bar ... 2.5 bar Protection class III: + Output signal: 4 mA ... 20 mA Vibration load: 10 g according to IEC 60068-2-6 (vibration under resonance), 20 g optional Process connection: G ¼ A according to DIN 3852-E Electrical safety: Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 32 V DC, 36 V DC with 4 mA ... 20 mA, Reverse pol
Specification: Part Number 6038629 Weight sensor: Ca. 80 g Enclosure rating: IP 67 Response time: < 4 ms Signal noise: &le; 0.3 % of span Rated temperature range: 0 °C ... +80 °C Housing material: Stainless steel 316L Measuring range: 0 bar ... 2.5 bar Accuracy: &le; ± 0,6 % of Span (with non-linearity 0.25 % and with signal output 0 ... 5 V), &le; ± 1 % of span (with non-linearity 0.25 %), &le; ± 1,0 %
Specification: Part Number 6038631 Relative humidity: 45 % ... 75 % Storage temperature: -20 °C ... +80 °C Ambient temperature: 0 °C ... +80 °C Response time: < 4 ms Seal: NBR Pressure type: Gauge pressure Shock load: 500 g according to IEC 60068-2-27 (mechanical shock) Medium: Liquid and gaseous media Reference conditions: Reference conditions: According to IEC 61298-1 Output signal: 0...10 V, 3-