SICK - Electronic pressure sensor PAC50

Image
Part Number
Description
Specification: Part Number 1062951 CULus certificate: - Vibration load: Max. 5 g (10 ... 150 Hz), xyz, according to DIN EN 60068-2-6 Output signal: 2 x PNP/NPN/Push-Pull Ambient temperature: 0 °C ... +60 °C CE-conformity: EMC directive: 2004/108/EC, EN 61326-2-3 Diagnostics output: Switching output 2 can be set as diagnostics output Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M and L+, Protec
Specification: Part Number 1062953 Diagnostics output: Switching output 2 can be set as diagnostics output Protection class III: + Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M and L+, Protection class: III, Overvoltage protection: 32 V DC, Reverse polarity protection: L+ towards M Enclosure rating: IP 65 / IP 67 According to IEC 60529 Power consumption: Max. 40 mA at L+ = 24 VDC Shock load: Max.
Specification: Part Number 1062945 Medium: Dry compressed air Measuring range: -1 bar ... 0 bar Pressure type: Gauge pressure Shock load: Max. 30 g, xyz according to IEC 60068-2-27 (11 ms, mechanical shock) Process temperature: 0 °C ... +60 °C Gauge pressure: -1 bar ... 0 bar; -1 bar ... +1 bar; 0 bar ... +6 bar; 0 bar ... +10 bar Non-linearity: ≤ ± 0.5 % (of span (Best Fit Straight Line, BFSL) according to
Specification: Part Number 1062946 Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M and L+, Protection class: III, Overvoltage protection: 32 V DC, Reverse polarity protection: L+ towards M Setting accuracy of switching outputs: ≤ ± 0.2 % of span Ambient temperature: 0 °C ... +60 °C Storage temperature: -20 °C ... +80 °C CRUus certificate: + Accuracy: ≤ ± 1.5 % of span (Including non-linea
Specification: Part Number 1062947 Initialization time: 300 ms Output signal: 2 x PNP/NPN/Push-Pull + 4 mA ... 20 mA / 0 V … 10 V Housing material: Seals: NBR, Housing: polycarbonate, DIN rail mounting: POM, Buttons: TPE Relative humidity: ≤ 90 % Pressure type: Gauge pressure Ambient temperature: 0 °C ... +60 °C CRUus certificate: + Protection class III: + Process connection: 2 x G ¼ Diagnostic
Specification: Part Number 1062964 Diagnostics output: Switching output 2 can be set as diagnostics output Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M and L+, Protection class: III, Overvoltage protection: 32 V DC, Reverse polarity protection: L+ towards M Non-repeatability: ≤ ± 0.2 % of span CRUus certificate: + Housing material: Seals: NBR, Housing: polycarbonate, DIN rail mounting: POM, Button
Specification: Part Number 1062965 Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M and L+, Protection class: III, Overvoltage protection: 32 V DC, Reverse polarity protection: L+ towards M Enclosure rating: IP 65 / IP 67 According to IEC 60529 CULus certificate: - Protection class III: + Analog signal output and ohmic load RA: Load resistance for voltage output > 3 kOhm, Load resistance for current outp
Specification: Part Number 1062966 Setting accuracy of switching outputs: ≤ ± 0.2 % of span Accuracy: ≤ ± 1.5 % of span (Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement according to IEC 61298-2)), ≤ ± 2 % of span incl. temperature error (Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement according to IEC 61298-
Specification: Part Number 1062967 Vibration load: Max. 5 g (10 ... 150 Hz), xyz, according to DIN EN 60068-2-6 Non-linearity: ≤ ± 0.5 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) Medium: Dry compressed air Non-repeatability: ≤ ± 0.2 % of span Power consumption: Max. 40 mA at L+ = 24 VDC Protection class III: + Rated temperature range: +10 °C ... +60 °C Process connection: PIF
Specification: Part Number 1062958 Shock load: Max. 30 g, xyz according to IEC 60068-2-27 (11 ms, mechanical shock) Setting accuracy of switching outputs: ≤ ± 0.2 % of span Medium: Dry compressed air Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M and L+, Protection class: III, Overvoltage protection: 32 V DC, Reverse polarity protection: L+ towards M Pressure type: Gauge pressure Relative humidit
Specification: Part Number 1062959 Storage temperature: -20 °C ... +80 °C Gauge pressure: -1 bar ... 0 bar; -1 bar ... +1 bar; 0 bar ... +6 bar; 0 bar ... +10 bar Rated temperature range: +10 °C ... +60 °C Ambient temperature: 0 °C ... +60 °C CRUus certificate: + Zero point adjustment: Max. + 5 % of span Non-repeatability: ≤ ± 0.2 % of span RoHS certificate: + Setting accuracy of switching outputs
Specification: Part Number 1062960 Ambient temperature: 0 °C ... +60 °C Display: Update: 1,000, 500, 200, 100 ms (adjustable), Pressure display: 4 digits, 16 segments, Pressure unit in display can be switched: bar, MPa, kPa, psi and inHg, LCD with LED backlight (green/red), can be rotated electronically by 180° Analog signal output and ohmic load RA: Load resistance for voltage output > 3 kOhm, Load resistance for current outp
Specification: Part Number 1062961 Ambient temperature: 0 °C ... +60 °C Relative humidity: ≤ 90 % Protection class III: + Zero point adjustment: Max. + 5 % of span CE-conformity: EMC directive: 2004/108/EC, EN 61326-2-3 Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M and L+, Protection class: III, Overvoltage protection: 32 V DC, Reverse polarity protection: L+ towards M Enclosure rating: IP
Specification: Part Number 1062977 Display: Update: 1,000, 500, 200, 100 ms (adjustable), Pressure display: 4 digits, 16 segments, Pressure unit in display can be switched: bar, MPa, kPa, psi and inHg, LCD with LED backlight (green/red), can be rotated electronically by 180° Relative humidity: ≤ 90 % Non-repeatability: ≤ ± 0.2 % of span Medium: Dry compressed air Gauge pressure: -1 bar ... 0 bar; -1 bar ... +1 bar
Specification: Part Number 1062978 Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M and L+, Protection class: III, Overvoltage protection: 32 V DC, Reverse polarity protection: L+ towards M Weight sensor: Ca. 40 g Housing material: Seals: NBR, Housing: polycarbonate, DIN rail mounting: POM, Buttons: TPE Relative humidity: ≤ 90 % CULus certificate: - Non-linearity: ≤ ± 0.5 % (of span (Best Fit S
Specification: Part Number 1062979 Analog signal output and ohmic load RA: Load resistance for voltage output > 3 kOhm, Load resistance for current output < 600 Ohm, Optional, 4 mA ... 20 mA / 0 V… 10 V. Automatic detection depending on connected load or programmable. Output signals can be inverted: 20 mA … 4 mA / 10 V … 0 V Enclosure rating: IP 65 / IP 67 According to IEC 60529 Output signal: 2 x PNP/NPN/Push-Pull + 4 mA
Specification: Part Number 1062970 CRUus certificate: + Ambient temperature: 0 °C ... +60 °C Accuracy: &le; ± 1.5 % of span (Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement according to IEC 61298-2)), &le; ± 2 % of span incl. temperature error (Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement according to IEC 612
Specification: Part Number 1062971 Non-repeatability: &le; ± 0.2 % of span Setting accuracy of switching outputs: &le; ± 0.2 % of span CE-conformity: EMC directive: 2004/108/EC, EN 61326-2-3 Accuracy: &le; ± 1.5 % of span (Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement according to IEC 61298-2)), &le; ± 2 % of span incl. temperature error (Including non-linearity,
Specification: Part Number 1062991 Diagnostics output: Switching output 2 can be set as diagnostics output Power consumption: Max. 40 mA at L+ = 24 VDC Storage temperature: -20 °C ... +80 °C Output signal: 2 x PNP/NPN/Push-Pull + 4 mA ... 20 mA / 0 V … 10 V Shock load: Max. 30 g, xyz according to IEC 60068-2-27 (11 ms, mechanical shock) Zero point adjustment: Max. + 5 % of span Electrical safety: Short-circuit
Specification: Part Number 1062992 Analog signal output and ohmic load RA: Load resistance for voltage output > 3 kOhm, Load resistance for current output < 600 Ohm, Optional, 4 mA ... 20 mA / 0 V… 10 V. Automatic detection depending on connected load or programmable. Output signals can be inverted: 20 mA … 4 mA / 10 V … 0 V Zero point adjustment: Max. + 5 % of span Protection class III: + Non-linearity: &le; ± 0.5 %
Specification: Part Number 1062983 Analog signal output and ohmic load RA: Load resistance for voltage output > 3 kOhm, Load resistance for current output < 600 Ohm, Optional, 4 mA ... 20 mA / 0 V… 10 V. Automatic detection depending on connected load or programmable. Output signals can be inverted: 20 mA … 4 mA / 10 V … 0 V Weight sensor: Ca. 40 g Gauge pressure: -1 bar ... 0 bar; -1 bar ... +1 bar; 0 bar ... +6 bar; 0 ba
Specification: Part Number 1062984 Initialization time: 300 ms Display: Update: 1,000, 500, 200, 100 ms (adjustable), Pressure display: 4 digits, 16 segments, Pressure unit in display can be switched: bar, MPa, kPa, psi and inHg, LCD with LED backlight (green/red), can be rotated electronically by 180° Process temperature: 0 °C ... +60 °C Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M and L+, Protection
Specification: Part Number 1062985 CULus certificate: - Initialization time: 300 ms Ambient temperature: 0 °C ... +60 °C RoHS certificate: + Medium: Dry compressed air Power consumption: Max. 40 mA at L+ = 24 VDC Display: Update: 1,000, 500, 200, 100 ms (adjustable), Pressure display: 4 digits, 16 segments, Pressure unit in display can be switched: bar, MPa, kPa, psi and inHg, LCD with LED backlight (green/red),
Specification: Part Number 1062952 Process temperature: 0 °C ... +60 °C Non-linearity: &le; ± 0.5 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) Accuracy: &le; ± 1.5 % of span (Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement according to IEC 61298-2)), &le; ± 2 % of span incl. temperature error (Including non-linearity, hysteresis, zero point and
Specification: Part Number 1062954 Shock load: Max. 30 g, xyz according to IEC 60068-2-27 (11 ms, mechanical shock) RoHS certificate: + Setting accuracy of switching outputs: &le; ± 0.2 % of span Accuracy: &le; ± 1.5 % of span (Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement according to IEC 61298-2)), &le; ± 2 % of span incl. temperature error (Including non-linear
Specification: Part Number 1062948 Pressure type: Gauge pressure Relative humidity: &le; 90 % Non-repeatability: &le; ± 0.2 % of span Diagnostics output: Switching output 2 can be set as diagnostics output Output signal: IO-Link/PNP + PNP/NPN/Push-Pull Power consumption: Max. 40 mA at L+ = 24 VDC Process connection: 2 x G ¼ Gauge pressure: -1 bar ... 0 bar; -1 bar ... +1 bar; 0 bar ... +6 bar; 0 bar ... +10
Specification: Part Number 1062973 RoHS certificate: + Storage temperature: -20 °C ... +80 °C Output signal: 2 x PNP/NPN/Push-Pull + 4 mA ... 20 mA / 0 V … 10 V Setting accuracy of switching outputs: &le; ± 0.2 % of span CE-conformity: EMC directive: 2004/108/EC, EN 61326-2-3 Gauge pressure: -1 bar ... 0 bar; -1 bar ... +1 bar; 0 bar ... +6 bar; 0 bar ... +10 bar Ambient temperature: 0 °C ... +60 °C Meas
Menu
Mail Us
enquiry@onstocktrading.com