PAC50-DCC

Specification: Part Number 1062991 Diagnostics output: Switching output 2 can be set as diagnostics output Power consumption: Max. 40 mA at L+ = 24 VDC Storage temperature: -20 °C ... +80 °C Output signal: 2 x PNP/NPN/Push-Pull + 4 mA ... 20 mA / 0 V … 10 V Shock load: Max. 30 g, xyz according to IEC 60068-2-27 (11 ms, mechanical shock) Zero point adjustment: Max. + 5 % of span Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M and L+, Protection class: III, Overvoltage protection: 32 V DC, Reverse polarity protection: L+ towards M RoHS certificate: + Ambient temperature: 0 °C ... +60 °C Non-repeatability: &le; ± 0.2 % of span Pressure type: Gauge pressure Process temperature: 0 °C ... +60 °C Setting accuracy of switching outputs: &le; ± 0.2 % of span Rated temperature range: +10 °C ... +60 °C Weight sensor: Ca. 40 g Initialization time: 300 ms CE-conformity: EMC directive: 2004/108/EC, EN 61326-2-3 Vibration load: Max. 5 g (10 ... 150 Hz), xyz, according to DIN EN 60068-2-6 Display: Update: 1,000, 500, 200, 100 ms (adjustable), Pressure display: 4 digits, 16 segments, Pressure unit in display can be switched: bar, MPa, kPa, psi and inHg, LCD with LED backlight (green/red), can be rotated electronically by 180° Analog signal output and ohmic load RA: Load resistance for voltage output > 3 kOhm, Load resistance for current output < 600 Ohm, Optional, 4 mA ... 20 mA / 0 V… 10 V. Automatic detection depending on connected load or programmable. Output signals can be inverted: 20 mA … 4 mA / 10 V … 0 V Housing material: Seals: NBR, Housing: polycarbonate, DIN rail mounting: POM, Buttons: TPE Enclosure rating: IP 65 / IP 67 According to IEC 60529 CRUus certificate: + Non-linearity: &le; ± 0.5 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) Accuracy: &le; ± 1.5 % of span (Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement according to IEC 61298-2)), &le; ± 2 % of span incl. temperature error (Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement according to IEC 61298-2)) Relative humidity: &le; 90 % Measuring range: 0 bar ... 10 bar Gauge pressure: -1 bar ... 0 bar; -1 bar ... +1 bar; 0 bar ... +6 bar; 0 bar ... +10 bar Process connection: PIF 4 mm + G ¼ Medium: Dry compressed air CULus certificate: - Protection class III: +
  • 1+ million product
    50+ Manufacturers
  • Free Shipping
    For orders from $50
  • Support 24/7
    Call us anytime
  • 100% Safety
    Only secure payments
Menu
Mail Us
enquiry@onstocktrading.com