Specification: Part Number 1053330 Resolution power: 16,384 x 131,072 Bearing lifetime: 3.0 x 10^9 revolutions Bus termination: DIP switch Enclosure rating: IP 67 (according to IEC 60529), housing, IP 67 (according to IEC 60529), Shaft Storage temperature range: -40 °C ... +100 °C Permissible relative humidity: 95 % (Condensation not permitted) Resistance to vibration: 30 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Resolution: 14 bit x 17 bit Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm Bus: PROFIBUS DP Flange material: Aluminum Operating voltage range: 10 V ... 32 V Initialization time: Ca. 1 s MTTFd: mean time to dangerous failure: 60 a (EN ISO 13849-1) EMC: (according to EN 61000-6-2 and EN 61000-6-3) Error limits: ± 0.35 ° (at room temperature) Working temperature range: -30 °C ... +80 °C Operating torque: 1.6 Ncm (+20 °C) Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 mm Connection type: 3 x M12, 5-pin, axial Data protocol: PROFIBUS DP V0, PROFIBUS DP V1 + V2 Max. number of steps per revolution: 16,384, programmable Shaft material: Stainless steel Electrical interface: PROFIBUS DP Max. angular acceleration: 500,000 rad/s² Resistance to shocks: 100 g, 6 ms (according to EN 60068-2-27) Data transmission rate (baud rate): ≤ 12 MBaud Mechanical interface: Blind hollow shaft Reverse polarity protection: 1 Max. number of revolutions: 131,072, programmable Mass: 0.28 kg Start up torque: 2 Ncm (+20 °C) Repeat accuracy: ± 0.15 ° (at room temperature) Shaft diameter: 8 mm Housing material: Aluminum