General specifications Switching element function PNP NC Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 3000 Hz Hysteresis typ. 5% Reverse polarity protection reverse polari
General specifications Switching element function DC NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.21 mm Reduction factor r Al 0.22 Reduction factor r Cu 0.16 Reduction factor r 304 0.64 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 1200 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection revers
General specifications Switching element function DC NC Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.21 mm Reduction factor r Al 0.22 Reduction factor r Cu 0.16 Reduction factor r 304 0.64 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 1200 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection revers
General specifications Switching element function NPN NO/NC Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Hysteresis typ. 5% Reverse polarity protection reverse po
General specifications Switching element function PNP NO/NC Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Hysteresis typ. 5% Reverse polarity protection reverse po
General specifications Switching element function NPN NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Reverse polarity protection reverse polarity protected Short-
General specifications Switching element function PNP NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Reverse polarity protection reverse polarity protected Short-
General specifications Switching element function DC NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.21 mm Reduction factor r Al 0.22 Reduction factor r Cu 0.16 Reduction factor r 304 0.64 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 1200 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection revers
General specifications Switching element function NPN NO/NC Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Hysteresis typ. 5% Reverse polarity protection reverse po
General specifications Switching element function PNP NO/NC Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Hysteresis typ. 5% Reverse polarity protection reverse po
General specifications Switching element function PNP NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 8 mm x 8 mm x 1 mm Reduction factor r Al 0.38 Reduction factor r Cu 0.2 Reduction factor r 304 0.8 Reduction factor r Brass 0.45 Nominal ratings Operating
General specifications Switching element function PNP NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 8 mm x 8 mm x 1 mm Reduction factor r Al 0.38 Reduction factor r Cu 0.2 Reduction factor r 304 0.8 Reduction factor r Brass 0.45 Nominal ratings Operating
General specifications Switching element function NPN NO Rated operating distance 1 mm Installation flush Output polarity DC Assured operating distance 0 ... 0.81 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.29 Reduction factor r 304 0.76 Reduction factor r Brass 0.46 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 700 Hz Hysteresis typ. 5% Reverse pol
General specifications Switching element function NPN NO Rated operating distance 1 mm Installation flush Output polarity DC Assured operating distance 0 ... 0.81 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.29 Reduction factor r 304 0.76 Reduction factor r Brass 0.46 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 700 Hz Hysteresis typ. 5% Reverse pol
General specifications Switching element function PNP NO Rated operating distance 1 mm Installation flush Output polarity DC Assured operating distance 0 ... 0.81 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.29 Reduction factor r 304 0.76 Reduction factor r Brass 0.46 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 700 Hz Hysteresis typ. 5% Reverse pol
General specifications Switching element function PNP NO Rated operating distance 1 mm Installation flush Output polarity DC Assured operating distance 0 ... 0.81 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.29 Reduction factor r 304 0.76 Reduction factor r Brass 0.46 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 700 Hz Hysteresis typ. 5% Reverse pol
General specifications Switching element function NPN NO Rated operating distance 1 mm Installation flush Output polarity DC Assured operating distance 0 ... 0.81 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.29 Reduction factor r 304 0.76 Reduction factor r Brass 0.46 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 700 Hz Hysteresis typ. 5% Reverse pol
General specifications Switching element function NPN NO Rated operating distance 1 mm Installation flush Output polarity DC Assured operating distance 0 ... 0.81 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.29 Reduction factor r 304 0.76 Reduction factor r Brass 0.46 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 700 Hz Hysteresis typ. 5% Reverse pol
General specifications Switching element function PNP NO Rated operating distance 1 mm Installation flush Output polarity DC Assured operating distance 0 ... 0.81 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.29 Reduction factor r 304 0.76 Reduction factor r Brass 0.46 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 700 Hz Hysteresis typ. 5% Reverse pol
General specifications Switching element function PNP NO Rated operating distance 1 mm Installation flush Output polarity DC Assured operating distance 0 ... 0.81 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.29 Reduction factor r 304 0.76 Reduction factor r Brass 0.46 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 700 Hz Hysteresis typ. 5% Reverse pol
General specifications Switching element function DC NO Rated operating distance 1 mm Installation flush Output polarity DC Assured operating distance 0 ... 0.81 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 8 mm x 8 mm x 1 mm Reduction factor r Al 0.38 Reduction factor r Cu 0.2 Reduction factor r 304 0.8 Reduction factor r Brass 0.45 Nominal ratings Installation
General specifications Switching element function AC NC Rated operating distance 10 mm Installation flush Output polarity AC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.29 Reduction factor r Cu 0.26 Reduction factor r 304 0.71 Nominal ratings Operating voltage 20 ... 250 V Switching frequency 0 ... 25 Hz Hysteresis typ. 5 % Short-circuit protection no Voltage drop
General specifications Switching element function AC NC Rated operating distance 10 mm Installation flush Output polarity AC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.29 Reduction factor r Cu 0.26 Reduction factor r 304 0.71 Nominal ratings Operating voltage 20 ... 250 V Switching frequency 0 ... 25 Hz Hysteresis typ. 5 % Short-circuit protection no Voltage drop
General specifications Switching element function AC NO Rated operating distance 10 mm Installation flush Output polarity AC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.29 Reduction factor r Cu 0.26 Reduction factor r 304 0.71 Nominal ratings Operating voltage 20 ... 250 V Switching frequency 0 ... 25 Hz Hysteresis typ. 5 % Short-circuit protection no Voltage drop
General specifications Switching element function NPN NO Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Reverse polarity protection reverse polarity protected Short-circuit
General specifications Switching element function PNP NO Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Reverse polarity protection reverse polarity protected Short-circuit
General specifications Switching element function PNP NO Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Reverse polarity protection reverse polarity protected Short-circuit
General specifications Switching element function PNP NO Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 30 mm x 30 mm x 1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Reduction factor r Brass 0.4 Nominal ratings Installation
General specifications Switching element function PNP NC Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 30 mm x 30 mm x 1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Reduction factor r Brass 0.4 Nominal ratings Installation
General specifications Switching element function AC NC Rated operating distance 10 mm Installation flush Output polarity AC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.28 Reduction factor r 304 0.82 Nominal ratings Operating voltage 20 ... 250 V Switching frequency 0 ... 20 Hz Hysteresis typ. 5 % Short-circuit protection no Voltage drop