General specifications Switching element function PNP NO Rated operating distance 1 mm Installation flush Output polarity DC Assured operating distance 0 ... 0.81 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.29 Reduction factor r 304 0.76 Reduction factor r Brass 0.46 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 700 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity protected Short-circuit protection pulsing Voltage drop less than or equal to 3 V Operating current 0 ... 100 mA Off-state current 0 ... 0.1 mA typ. at 25 °C No-load supply current less than or equal to 10 mA Switching state indicator LED, yellow Functional safety related parameters MTTF d 1340 a Mission Time (T M ) 20 a Diagnostic Coverage (DC) 0 % Approvals and certificates UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose CCC approval CCC approval / marking not required for products rated less than or equal to 36 V Ambient conditions Ambient temperature -25 ... 70 °C (-13 ... 158 °F) Mechanical specifications Connection type Cable connector M8 x 1 , 3-pin with PVC cable 300 mm Core cross-section 0.055 mm 2 Housing material Stainless steel 1.4305 / AISI 303 Sensing face PC Housing diameter 3 mm Degree of protection IP67