Image
Part Number
Description
General specifications Switching element function NAMUR, NC Rated operating distance 2 mm Installation flush Assured operating distance 0 ... 1.62 mm Nominal ratings Nominal voltage 8.2 V Operating voltage 5 ... 15 V Switching frequency 0 ... 1000 Hz Current consumption Measuring plate not detected min. 2.7 mA Measuring plate detected less than or equal to 1.8 mA Compliance with standards and dir
General specifications Switching element function NPN NO Rated operating distance 5 mm Installation non-flush Assured operating distance 0 ... 4.05 mm Nominal ratings Operating voltage 4.75 ... 30 V DC Switching frequency 0 ... 500 Hz Voltage drop less than or equal to 1 V Temperature drift ± 15% Operating current 0 ... 25 mA No-load supply current less than or equal to 10 mA Approvals and certific
General specifications Switching element function AC/DC normally open Rated operating distance 7 mm Installation flush Output polarity AC/DC Nominal ratings Operating voltage 20 ... 250 V AC/DC Switching frequency 15 Hz Hysteresis 2 ... 15 % 5 typ. Reverse polarity protection reverse polarity protected Short-circuit protection no Voltage drop less than or equal to 7 V Operating current 8 ... 200 mA
General specifications Switching element function NAMUR, NC Rated operating distance 7 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 5.67 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Operating voltage 5 ... 25 V Switching frequency 0 ... 200 Hz Hysteresis typ. %
General specifications Switching element function PNP NO Rated operating distance 5 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 4.05 mm Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 400 Hz Reverse polarity protection reverse polarity protected Short-circuit protection pulsing Voltage drop less than or equal to 1.5 V Operating current 0 ...
General specifications Switching element function PNP NC Slot width 3 mm Depth of immersion (lateral) 5 ... 7 typ. 6 mm Installation Output polarity DC Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 2000 Hz Reverse polarity protection reverse polarity protected Short-circuit protection pulsing Operating current 0 ... 200 mA No-load supply current less than or equal to 15 m
General specifications Switching element function PNP NO Slot width 3.5 mm Depth of immersion (lateral) 4 ... 6 typ. 6 mm Installation Output polarity DC Nominal ratings Operating voltage 6 ... 30 V Switching frequency 0 ... 2000 Hz Reverse polarity protection reverse polarity protected Short-circuit protection yes Voltage drop less than or equal to 3 V Operating current 0 ... 100 mA No-load su
General specifications Switching element function Analog current output Installation non-flush Output polarity DC Measurement range 5 ... 15 mm Nominal ratings Operating voltage 15 ... 30 V Repeat accuracy 0 ... 15 mm No-load supply current less than or equal to 10 mA Functional safety related parameters MTTF d 2880 a Mission Time (T M ) 20 a Diagnostic Coverage (DC) 0 % Analog output Output ty
General specifications Switching element function Analog current output Installation non-flush Output polarity DC Measurement range 5 ... 15 mm Nominal ratings Operating voltage 15 ... 30 V Repeat accuracy 0 ... 15 mm No-load supply current less than or equal to 10 mA Analog output Output type 0 ... 20 mA Linearity error less than or equal to ± 10 % of full-scale value Load resistor less than or equa
General specifications Switching element function Analog voltage output Installation quasi flush Output polarity DC Measurement range 0 ... 6 mm Nominal ratings Operating voltage 10 ... 30 V Limit frequency (3dB) 1000 Hz Reverse polarity protection yes Short-circuit protection yes Repeat accuracy 0 ... 1 mm No-load supply current less than or equal to 10 mA Analog output Output type 0 ... 5 V L
General specifications Switching element function analog, current or voltage output Installation quasi flush Output polarity DC Measurement range 0 ... 6 mm Nominal ratings Operating voltage 15 ... 30 V , residual ripple 20 % U B Limit frequency (3dB) 1000 Hz Reverse polarity protection yes Short-circuit protection yes Repeat accuracy 0 ... 10 mm No-load supply current less than or equal to 10 mA Ana
General specifications Switching element function Analog current output Installation flush Output polarity DC Measurement range 3 ... 8 mm Nominal ratings Operating voltage 15 ... 30 V Repeat accuracy 0 ... 15 mm No-load supply current less than or equal to 10 mA Functional safety related parameters MTTF d 2860 a Mission Time (T M ) 20 a Diagnostic Coverage (DC) 0 % Analog output Output type 0
General specifications Switching element function Analog current output Installation non-flush Output polarity DC Measurement range 3 ... 8 mm Nominal ratings Operating voltage 15 ... 30 V Repeat accuracy 0 ... 6 mm No-load supply current less than or equal to 8 mA Functional safety related parameters MTTF d 2690 a Mission Time (T M ) 20 a Diagnostic Coverage (DC) 0 % Analog output Output type
General specifications Switching element function NPN NO Rated operating distance 0.6 mm Installation flush Output polarity DC Assured operating distance 0 ... 0.486 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.29 Reduction factor r 304 0.76 Reduction factor r Brass 0.46 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1400 Hz Hysteresis typ. 5% Reverse
General specifications Switching element function NPN NO Rated operating distance 0.6 mm Installation flush Output polarity DC Assured operating distance 0 ... 0.486 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.29 Reduction factor r 304 0.76 Reduction factor r Brass 0.46 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1400 Hz Hysteresis typ. 5% Reverse
General specifications Switching element function NPN NC Rated operating distance 0.6 mm Installation flush Output polarity DC Assured operating distance 0 ... 0.486 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.29 Reduction factor r 304 0.76 Reduction factor r Brass 0.46 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1300 Hz Hysteresis typ. 5% Reverse
General specifications Switching element function PNP NO Rated operating distance 0.6 mm Installation flush Output polarity DC Assured operating distance 0 ... 0.486 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.29 Reduction factor r 304 0.76 Reduction factor r Brass 0.46 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1400 Hz Hysteresis typ. 5% Reverse
General specifications Switching element function PNP NO Rated operating distance 0.6 mm Installation flush Output polarity DC Assured operating distance 0 ... 0.486 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.29 Reduction factor r 304 0.76 Reduction factor r Brass 0.46 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1400 Hz Hysteresis typ. 5% Reverse
General specifications Switching element function PNP NC Rated operating distance 0.6 mm Installation flush Output polarity DC Assured operating distance 0 ... 0.486 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.29 Reduction factor r 304 0.76 Reduction factor r Brass 0.46 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1300 Hz Hysteresis typ. 5% Reverse
General specifications Switching element function NPN NO Rated operating distance 0.6 mm Installation flush Output polarity DC Assured operating distance 0 ... 0.486 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.29 Reduction factor r 304 0.76 Reduction factor r Brass 0.46 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1400 Hz Hysteresis typ. 5% Reverse
General specifications Switching element function NPN NC Rated operating distance 0.6 mm Installation flush Output polarity DC Assured operating distance 0 ... 0.486 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.29 Reduction factor r 304 0.76 Reduction factor r Brass 0.46 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1300 Hz Hysteresis typ. 5% Reverse
General specifications Switching element function PNP NO Rated operating distance 0.6 mm Installation flush Output polarity DC Assured operating distance 0 ... 0.486 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.29 Reduction factor r 304 0.76 Reduction factor r Brass 0.46 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1400 Hz Hysteresis typ. 5% Reverse
General specifications Switching element function PNP NO Rated operating distance 0.6 mm Installation flush Output polarity DC Assured operating distance 0 ... 0.486 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.29 Reduction factor r 304 0.76 Reduction factor r Brass 0.46 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1400 Hz Hysteresis typ. 5% Reverse
General specifications Switching element function PNP NC Rated operating distance 0.6 mm Installation flush Output polarity DC Assured operating distance 0 ... 0.486 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.29 Reduction factor r 304 0.76 Reduction factor r Brass 0.46 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1300 Hz Hysteresis typ. 5% Reverse
General specifications Switching element function NPN NO Rated operating distance 0.8 mm Installation flush Output polarity DC Assured operating distance 0 ... 0.648 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 3000 Hz Hysteresis 5 ... 20 % Reverse polarity protection reverse pol
General specifications Switching element function NPN NO Rated operating distance 0.8 mm Installation flush Output polarity DC Assured operating distance 0 ... 0.648 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 3000 Hz Hysteresis 5 ... 20 % Reverse polarity protection reverse pol
General specifications Switching element function NPN NO Rated operating distance 0.8 mm Installation flush Output polarity DC Assured operating distance 0 ... 0.648 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 3000 Hz Hysteresis 5 ... 20 % Reverse polarity protection reverse pol
General specifications Switching element function NPN NO Rated operating distance 0.8 mm Installation flush Output polarity DC Assured operating distance 0 ... 0.648 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 3000 Hz Hysteresis typ. 5% Reverse polarity protection reverse polari
General specifications Switching element function NPN NC Rated operating distance 0.8 mm Installation flush Output polarity DC Assured operating distance 0 ... 0.648 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 3000 Hz Hysteresis 5 ... 20 % Reverse polarity protection reverse pol
General specifications Switching element function PNP NO Rated operating distance 0.8 mm Installation flush Output polarity DC Assured operating distance 0 ... 0.648 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.77 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 3000 Hz Hysteresis typ. 5% Reverse polarity protection reverse polari