NBB10-30GKK-WO

General specifications Switching element function AC NC Rated operating distance 10 mm Installation flush Output polarity AC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.28 Reduction factor r 304 0.82 Nominal ratings Operating voltage 20 ... 250 V Switching frequency 0 ... 20 Hz Hysteresis typ. 5 % Short-circuit protection no Voltage drop less than or equal to 8 V Momentary current (20 ms, 0.1 Hz) 0 ... 1600 mA Operating current 1.5 ... 200 mA No-load supply current less than or equal to 1.7 mA Approvals and certificates UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose CCC approval Certified by China Compulsory Certification (CCC) Ambient conditions Ambient temperature -25 ... 70 °C (-13 ... 158 °F) Mechanical specifications Connection type terminal compartment Core cross-section up to 2.5 mm 2 Housing material PBT Sensing face PBT Housing diameter 30 mm Degree of protection IP67 Note 1) In the temperature range below 0 °C, permissible operating voltage U b 80...253 V Safety fuse less than or equal to 0.8 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly.
  • 1+ million product
    50+ Manufacturers
  • Free Shipping
    For orders from $50
  • Support 24/7
    Call us anytime
  • 100% Safety
    Only secure payments
Menu
Mail Us
enquiry@onstocktrading.com