General specifications Switching element function NPN NO/NC Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 500 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity
General specifications Switching element function PNP NO/NC Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 500 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity
General specifications Switching element function PNP NO/NC Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 6.08 mm ( -40 ... -25 °C (-40 ... -13 °F) ) Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequ
General specifications Switching element function PNP NO/NC Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % Reverse polarity protection reverse pola
General specifications Switching element function NO/NC programmable Rated operating distance 8 mm Installation flush Output polarity AS-Interface Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Reduction factor r Brass 0.5 Slave type Standard slave AS-Interface specification V2.1 Required master specification greater or
General specifications Switching element function NO/NC programmable Rated operating distance 8 mm Installation flush Output polarity AS-Interface Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Reduction factor r Brass 0.5 Slave type A/B slave AS-Interface specification V3.0 Required master specification greater or equa
General specifications Switching element function NC contact Rated operating distance 8 mm Installation flush Output polarity AC/DC NC contact Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 20 ... 250 V AC/20 ... 300 V DC Switching frequency 30 Hz Hysteresis 3 ... 15 typ. 5 % Reverse polarity protection yes Short-circuit prot
PPRL_no_foto.jpg
General specifications Switching element function AC/DC NO Rated operating distance 8 mm Installation flush Output polarity AC/DC NO contact Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 20 ... 250 V AC/20 ... 300 V DC Switching frequency 30 Hz Hysteresis 3 ... 15 typ. 5 % Reverse polarity protection reverse polarity tolerant
General specifications Switching element function AC/DC NO Rated operating distance 8 mm Installation flush Output polarity AC/DC NO contact Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 20 ... 250 V AC/20 ... 300 V DC Switching frequency 30 Hz Hysteresis 3 ... 15 typ. 5 % Reverse polarity protection reverse polarity tolerant
PPRL_no_foto.jpg
General specifications Switching element function PNP NO Rated operating distance 12 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 9.72 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.35 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 300 Hz Hysteresis typ. 5% Reverse polarity protection reverse polar
General specifications Switching element function PNP NO Rated operating distance 12 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 9.72 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.35 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 300 Hz Hysteresis typ. 5% Reverse polarity protection reverse polar
General specifications Switching element function PNP NC Rated operating distance 12 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 9.72 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.35 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 300 Hz Hysteresis type 5 % Reverse polarity protection reverse pola
General specifications Switching element function NPN NO/NC Rated operating distance 12 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 9.72 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1000 Hz Hysteresis typ. 5% Reverse polarity protection reverse po
General specifications Switching element function NPN NO/NC Rated operating distance 12 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 9.72 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1000 Hz Hysteresis typ. 5% Reverse polarity protection reverse po
General specifications Switching element function PNP NO/NC Rated operating distance 12 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 9.72 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1000 Hz Hysteresis typ. 5% Reverse polarity protection reverse po
General specifications Switching element function PNP NO/NC Rated operating distance 12 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 9.72 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1000 Hz Hysteresis typ. 5% Reverse polarity protection reverse po
General specifications Switching element function NPN NO Rated operating distance 12 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 9.72 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarit
General specifications Switching element function NPN NO Rated operating distance 12 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 9.72 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 200 Hz Hysteresis type 5 % Reverse polarity protection reverse polar
General specifications Switching element function NPN NO Rated operating distance 12 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 9.72 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarit
General specifications Switching element function NPN NO Rated operating distance 12 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 9.72 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 200 Hz Hysteresis type 5 % Reverse polarity protection reverse polar
General specifications Switching element function NPN NC Rated operating distance 12 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 9.72 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 200 Hz Hysteresis type 5 % Reverse polarity protection reverse polar
General specifications Switching element function NPN NC Rated operating distance 12 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 9.72 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 200 Hz Hysteresis type 5 % Reverse polarity protection reverse polar
General specifications Switching element function PNP NO Rated operating distance 12 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 9.72 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarit
General specifications Switching element function PNP NO Rated operating distance 12 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 9.72 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 200 Hz Hysteresis type 5 % Reverse polarity protection reverse polar
General specifications Switching element function PNP NO Rated operating distance 12 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 9.72 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarit
General specifications Switching element function PNP NO Rated operating distance 12 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 9.72 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 200 Hz Hysteresis type 5 % Reverse polarity protection reverse polar
General specifications Switching element function PNP NC Rated operating distance 12 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 9.72 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 200 Hz Hysteresis type 5 % Reverse polarity protection reverse polar
General specifications Switching element function PNP NC Rated operating distance 12 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 9.72 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 200 Hz Hysteresis type 5 % Reverse polarity protection reverse polar