General specifications Switching element function AC NO Rated operating distance 5 mm Installation flush Output polarity AC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.2 Reduction factor r Cu 0.2 Reduction factor r 304 0.6 Nominal ratings Operating voltage 20 ... 253 V Switching frequency 0 ... 20 Hz Hysteresis typ. 6 % Voltage drop < 5 V (I L > 50 mA)- < 8 V (I L
General specifications Switching element function AC NO Rated operating distance 5 mm Installation flush Output polarity AC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.2 Reduction factor r Cu 0.2 Reduction factor r 304 0.6 Nominal ratings Operating voltage 20 ... 253 V Switching frequency 0 ... 20 Hz Hysteresis typ. 6 % Reverse polarity protection yes Short-circuit
General specifications Switching element function PNP NO Rated operating distance 5 mm Installation flush Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Reduction factor r St37 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 800 Hz Reverse polarity protection reverse polarity protected Short
General specifications Switching element function PNP NO Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 500 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity pr
General specifications Switching element function PNP NO Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 6.08 mm ( -40 ... -25 °C (-40 ... -13 °F) ) Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequenc
General specifications Switching element function PNP NC Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 500 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity pr
General specifications Switching element function PNP NC Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 6.08 mm ( -40 ... -25 °C (-40 ... -13 °F) ) Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequenc
General specifications Switching element function NPN NO Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity p
General specifications Switching element function NPN NO Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 400 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity p
General specifications Switching element function NPN NO Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 500 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity pr
General specifications Switching element function NPN NO Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 400 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity p
General specifications Switching element function NPN NC Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 400 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity p
General specifications Switching element function NPN NC Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 400 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity p
General specifications Switching element function PNP NO Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 500 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity pr
General specifications Switching element function PNP NO Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarit
General specifications Switching element function PNP NO Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity p
General specifications Switching element function PNP NO Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity p
General specifications Switching element function PNP NO Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 400 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity p
General specifications Switching element function PNP NO Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 400 Hz Hysteresis typ. 5 % Reverse polarity protection yes Short-circu
General specifications Switching element function PNP NO Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 6.08 mm ( -40 ... -25 °C (-40 ... -13 °F) ) Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequenc
General specifications Switching element function PNP NO Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarit
General specifications Switching element function PNP NO Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 400 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity p
General specifications Switching element function PNP NC Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 400 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity p
General specifications Switching element function PNP NC Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 400 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity p
General specifications Switching element function NPN NO/NC Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarit