General specifications Switching element function NC contact Rated operating distance 15 mm Installation non-flush Output polarity AC/DC NC contact Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 20 ... 250 V AC/20 ... 300 V DC Switching frequency 30 Hz Hysteresis 3 ... 15 typ. 5 % Reverse polarity protection yes Short-circuit
General specifications Switching element function NC contact Rated operating distance 15 mm Installation non-flush Output polarity AC/DC NC contact Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 20 ... 250 V AC/20 ... 300 V DC Switching frequency 30 Hz Hysteresis 3 ... 15 typ. 5 % Reverse polarity protection yes Short-circuit
General specifications Switching element function AC/DC NO Rated operating distance 15 mm Installation non-flush Output polarity AC/DC NO contact Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 20 ... 250 V AC/20 ... 300 V DC Switching frequency 30 Hz Hysteresis 3 ... 15 typ. 5 % Reverse polarity protection reverse polarity tol
General specifications Switching element function NPN NO Rated operating distance 15 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Reverse polarity protection reverse polarity protected Short-c
General specifications Switching element function PNP NO Rated operating distance 15 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Reverse polarity protection reverse polarity protected Short-c
General specifications Switching element function PNP NO Rated operating distance 15 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 12.15 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 45 mm x 45 mm x 1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Reduction factor r Brass 0.4 Nominal ratings Instal
General specifications Switching element function PNP NC Rated operating distance 15 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 12.15 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 45 mm x 45 mm x 1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Reduction factor r Brass 0.4 Nominal ratings Instal
General specifications Switching element function SPDT Relay Rated operating distance 15 mm Installation non-flush Output polarity DC Reduction factor r Al 0.4 Reduction factor r Cu 0.37 Reduction factor r 304 0.73 Mechanical life 2 x 10 7 operations Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 5 Hz Hysteresis 3 ... 15 % , typ. 5 % Reverse polarity protection yes
General specifications Switching element function SPDT Relay Rated operating distance 15 mm Installation non-flush Output polarity DC Reduction factor r Al 0.4 Reduction factor r Cu 0.37 Reduction factor r 304 0.73 Mechanical life 2 x 10 7 operations Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 5 Hz Hysteresis 3 ... 15 % , typ. 5 % Reverse polarity protection yes
General specifications Switching element function DC NO Rated operating distance 15 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 12.2 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.35 Reduction factor r 304 0.7 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 150 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection revers
General specifications Switching element function DC NO Rated operating distance 15 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 12.15 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 11.4 mm ( -40 ... -25 °C (-40 ... -13 °F) ) Reduction factor r Al 0.4 Reduction factor r Cu 0.35 Reduction factor r 304 0.7 Nominal ratings Operating voltage 5 ... 60 V Switching freq
General specifications Switching element function DC NO Rated operating distance 15 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 12.2 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.35 Reduction factor r 304 0.7 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 150 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection revers
General specifications Switching element function NPN NO Rated operating distance 15 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5% Reverse polarity protection reverse polari
General specifications Switching element function NPN NO Rated operating distance 15 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5% Reverse polarity protection reverse polari
General specifications Switching element function PNP NO Rated operating distance 15 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5% Reverse polarity protection reverse polari
General specifications Switching element function PNP NO Rated operating distance 15 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 12.15 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 11.4 mm ( -40 ... -25 °C (-40 ... -13 °F) ) Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 30 V Switching fre
General specifications Switching element function PNP NC Rated operating distance 15 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 12.15 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 45 mm x 45 mm x 1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Reduction factor r Brass 0.4 Nominal ratings Instal
General specifications Switching element function NPN NO/NC Rated operating distance 15 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5% Reverse polarity protection reverse p
General specifications Switching element function NPN NO/NC Rated operating distance 15 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5% Reverse polarity protection reverse p
General specifications Switching element function PNP NO/NC Rated operating distance 15 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5% Reverse polarity protection reverse p
General specifications Switching element function PNP NO/NC Rated operating distance 15 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Reverse polarity protection reverse polarity protected Sh
General specifications Switching element function PNP NO/NC Rated operating distance 15 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Reverse polarity protection reverse polarity protected Sh
General specifications Switching element function NPN NO Rated operating distance 2 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Reverse polarity protection reverse polarity protected Short
General specifications Switching element function PNP NO Rated operating distance 2 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Reverse polarity protection reverse polarity protected Short
General specifications Switching element function PNP NO Rated operating distance 2 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 2000 Hz Hysteresis typ. 5% Reverse polarity protection reverse polar
General specifications Switching element function DC NC Rated operating distance 2 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.39 Reduction factor r 304 0.75 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 1200 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection rever
General specifications Switching element function NPN NO/NC Rated operating distance 2 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Reverse polarity protection reverse polarity protected Sh