Code sequence CW/CCW coded by connection Size (flange) ø75 mm Initializing time typ. 50 ms after power on Operating speed ≤6000 rpm (mechanical) ≤6000 rpm (electric) manufacter SKU GXN1H Number of cams 250 Voltage supply 10...30 VDC Protection DIN EN 60529 IP 54 Reverse polarity protection Yes Diagnostic functions Code continuity check Signal frequency exceeded Materials Housing: steel Flange: aluminium Connection Cable 1 m, connector DSUB, 37pin Relative humidity 95 % non-condensing Programming interface RS232 Emitted interference DIN EN 61000-6-4 Code Binary Resistance DIN EN 60068-2-6 Vibration 10 g, 16-2000 Hz DIN EN 60068-2-27 Shock 200 g, 6 ms Rotor moment of inertia 20 gcm² Sensing method Optical Inputs TxD, RxD (RS232) Control signals UP/ DOWN and zero ENABLE Weight approx. 700 g Consumption w/o load ≤50 mA (24 VDC) Shaft type ø14 mm (through hollow shaft) Approval UL approval / E63076 Output stages PNP or NPN open collector Starting torque ≤0.05 Nm (IP 54) Function Multiturn Interfaces Parallel (cams) 5 special outputs programmable Programmable parameters Steps per revolution Number of revolutions 2 presets (limits) Rotation speed monitoring Steps per turn ≤4096 / 12 bit Absolute accuracy ±0.03 ° Operating temperature -25...+70 °C Number of turns ≤4096 / 12 bit Interference immunity DIN EN 61000-6-2