Weight approx. 300 g Phase shift 90° ±10° Resistance DIN EN 60068-2-6 Vibration 30 g, 10-2000 Hz DIN EN 60068-2-27 Shock 250 g, 6 ms manufacter SKU EIL580-T - through hollow shaft Scan ratio 40...60 % Connection Flange connector M12, 8-pin Flange connector M23, 12-pin Cable Emitted interference DIN EN 61000-6-3 Size (flange) ø58 mm Pulses per revolution 100...5000 Starting torque ≤0.02 Nm (+20 °C, IP 65) ≤0.025 Nm (+20 °C, IP 67) Reverse polarity protection Yes Short-circuit proof Yes (HTL) Yes (TTL, max. 1 s and 1 signal) Approval UL 508 / CSA 22.2 Operating speed ≤3000 rpm (+20 °C, IP 67) ≤6000 rpm (+20 °C, IP 65) Protection DIN EN 60529 IP 65 (without shaft seal) IP 67 (with shaft seal) Voltage supply 5 VDC ±5 % 8...30 VDC 4.75...30 VDC EIL580-T - through hollow shaft output signals A+, B+, R+, A-, B-, R- Relative humidity 90 % non-condensing Reference signal Zero pulse, width 90° ±10 % Consumption w/o load ≤70 mA Output stages TTL/RS422 HTL/push-pull Output frequency ≤300 kHz (TTL) ≤160 kHz (HTL) Interference immunity DIN EN 61000-6-2 Shaft type ø8...15 mm (through hollow shaft) Materials Housing: aluminium die-cast Flange: aluminium Operating temperature -40...+85 °C Motor shaft tolerance 0.2 mm axial 0.03 mm radial Sensing method Optical