Resistance DIN EN 60068-2-6 Vibration 30 g, 10-2000 Hz DIN EN 60068-2-27 Shock 300 g, 6 ms Protection DIN EN 60529 IP 65 (without shaft seal) IP 67 (with shaft seal) Reference signal Zero pulse, width 90° ±10 % Output frequency ≤300 kHz (TTL) ≤160 kHz (HTL) Weight approx. 300 g Sensing method Optical Operating speed ≤6000 rpm (+20 °C, IP 67) ≤12000 rpm (+20 °C, IP 65) Short-circuit proof Yes (HTL) Yes (TTL, max. 1 s and 1 signal) Pulses per revolution 100...5000 Relative humidity 90 % non-condensing Admitted shaft load ≤40 N axial ≤80 N radial Output stages TTL/RS422 HTL/push-pull Consumption w/o load ≤70 mA EIL580-SY - synchro flange output signals A+, B+, R+, A-, B-, R- Voltage supply 5 VDC ±5 % 8...30 VDC 4.75...30 VDC manufacter SKU EIL580-SY - synchro flange Shaft type ø6 x 10 mm, solid shaft with flat (synchro flange) Reverse polarity protection Yes Phase shift 90° ±10° Connection Flange connector M12, 8-pin Flange connector M23, 12-pin Cable Approval UL 508 / CSA 22.2 Operating temperature -40...+85 °C Interference immunity DIN EN 61000-6-2 Size (flange) ø58 mm Emitted interference DIN EN 61000-6-3 Scan ratio 40...60 % Materials Housing: aluminium die-cast Flange: aluminium Solid shaft: stainless steel Starting torque ≤0.015 Nm (+20 °C, IP 65) ≤0.02 Nm (+20 °C, IP 67)