SIMOTICS L COMBINED CROSS CONNECTOR; FRAME SIZE 100; WITH COUPLING; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; FOR WATER DISTRIBUTION AND HOLDING DOWN OF COVER BAND AT THE END OF THE SECONDARY SECTION TRACK
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; STYLE DEPT CONTINUOUS LOAD SPECIFICATION; SEPARATE CONNECTION OF POWER AND SIGNAL; COVER PREPARED FOR METRIC SCREW GLAND; FN=300N; FMAX=510N; VMAX_FN=214M/MIN; VMAX=117M/MIN; IN=2,9A; IMAX=5,9A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL IN ONE CABLE; COVER IS PREPARED FOR PLASTIC CONDUIT COUPLING; FN=200N; FMAX=490N; VMAX_FN=322M/MIN; VMAX=138M/MIN; IN=2,4A; IMAX=6,5A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; COVER PREPARED FOR METRIC SCREW GLAND; SEPARATE CONNECTION OF POWER AND SIGNAL; FN=200N; FMAX=490N; VMAX_FN=322M/MIN; VMAX_FMAX=138M/MIN; IN=2,4A; IMAX=6,5A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; CONTINUOUS LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL SEPARATED; CABLES TIGHTLY MOUNTED; LENGTH 2M; FN=605N; FMAX=1020N; VMAX_FN=307M/MIN; VMAX=170M/MIN IN=8A; IMAX=16,5A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL IN ONE CABLE; COVER IS PREPARED FOR PLASTIC CONDUIT COUPLING; FN=450N; FMAX=110N; VMAX-FN=297M/MIN; VMAX=131M/MIN; IN=5,1A; IMAX=13,5A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS WHEN OPERATING DIRECT MOTORS VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; COVER PREPARED FOR METRIC SCREW GLAND; SEPARATE CONNECTION OF POWER AND SIGNAL; FN=450N; FMAX=110N; VMAX_FN=297M/MIN; VMAX_FMAX=131M/MIN; IN=5,1A; IMAX=13,5A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS WHEN OPERATING DIRECT MOTORS VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL IN ONE CABLE; COVER IS PREPARED FOR PLASTIC CONDUIT COUPLING; FN=540N; FMAX=1100N; VMAX_FN=497M/MIN; VMAX=237M/MIN; IN=8,1A; IMAX=21,5A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS WHEN OPERATING DIRECT MOTORS VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; COVER PREPARED FOR METRIC SCREW GLAND; SEPARATE CONNECTION OF POWER AND SIGNAL; FN=540N; FMAX=1100N; VMAX_FN=497M/MIN; VMAX_FMAX=237M/MIN; IN=8,1A; IMAX=21,5A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS WHEN OPERATING DIRECT MOTORS VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; STYLE DEPT CONTINUOUS LOAD SPECIFICATION; SEPARATE CONNECTION OF POWER AND SIGNAL; COVER PREPARED FOR METRIC SCREW GLAND; FN=905N; FMAX=1530N; VMAX_FN=211M/MIN; VMAX=115M/MIN; IN=8,5A; IMAX=17,6A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL IN ONE CABLE; COVER IS PREPARED FOR PLASTIC CONDUIT COUPLING; FN=675N; FMAX=1650N; VMAX_FN=277M/MIN; VMAX=120M/MIN; IN=7,2A; IMAX=19,1A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; COVER PREPARED FOR METRIC SCREW GLAND; SEPARATE CONNECTION OF POWER AND SIGNAL; FN=675N; FMAX=1650N; VMAX_FN=277M/MIN; VMAX_FMAX=120M/MIN; IN=7,2A; IMAX=19,1A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL IN ONE CABLE; COVER IS PREPARED FOR PLASTIC CONDUIT COUPLING; FN=675N; FMAX=1650N; VMAX_FN=497M/MIN; VMAX=237M/MIN; IN=12,1A; IMAX=32,2A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; COVER PREPARED FOR METRIC SCREW GLAND; SEPARATE CONNECTION OF POWER AND SIGNAL; FN=675N; FMAX=1650N; VMAX_FN=497M/MIN; VMAX_FMAX=237M/MIN; IN=12,1A; IMAX=32,2A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; STYLE DEPT CONTINUOUS LOAD SPECIFICATION; SEPARATE CONNECTION OF POWER AND SIGNAL; COVER PREPARED FOR METRIC SCREW GLAND; FN=1205N; FMAX=2040N; VMAX_FN=305M/MIN; VMAX=169M/MIN; IN=15,9A; IMAX=33,1A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED
SIMOTICS L COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 100; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 2,5 SECONDARY SECTION SEGMENTS
SIMOTICS L COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 100; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 3 SECONDARY SECTION SEGMENTS
SIMOTICS L COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 100; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 3,5 SECONDARY SECTION SEGMENTS
SIMOTICS L COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 100; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 4 SECONDARY SECTION SEGMENTS
SIMOTICS L COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 100; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 5 SECONDARY SECTION SEGMENTS
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL IN ONE CABLE; COVER IS PREPARED FOR PLASTIC CONDUIT COUPLING; FN=900N; FMAX=2200N; VMAX_FN=297M/MIN; VMAX=131M/MIN; IN=10,1A; IMAX=27A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; COVER PREPARED FOR METRIC SCREW GLAND; SEPARATE CONNECTION OF POWER AND SIGNAL; FN=900N; FMAX=2200N; VMAX_FN=297M/MIN; VMAX_FMAX=131M/MIN; IN=10,1A; IMAX=27A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED