SIMOTICS L SECONDARY SECTION COOLING WITH COUPLING; FRAME SIZE 900; HOLLOW PROFILE - ALUMINIUM; 3 PER SECONDARY SECTION TRACK; LENGTH IN NUMBER OF SECONDARY SECTIONS: 14
SIMOTICS L SECONDARY SECTION COOLING WITH COUPLING; FRAME SIZE 900; HOLLOW PROFILE - ALUMINIUM; 3 PER SECONDARY SECTION TRACK; LENGTH IN NUMBER OF SECONDARY SECTIONS: 15
SIMOTICS L SECONDARY SECTION COOLING WITH COUPLING; FRAME SIZE 900; HOLLOW PROFILE - ALUMINIUM; 3 PER SECONDARY SECTION TRACK; LENGTH IN NUMBER OF SECONDARY SECTIONS: 16
SIMOTICS L SECONDARY SECTION COOLING WITH HOSE CONNECTOR ON BOTH ENDS; FRAME SIZE 600; HOLLOW PROFILE - ALUMINIUM; 3 PER SECONDARY SECTION TRACK; LENGTH IN NUMBER OF SECONDARY SECTIONS: 2
SIMOTICS L COMBINED END-PIECE FOR FRAME SIZE 050; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; FOR WATER-REDIRECTION AND HOLDING DOWN OF COVER BAND AT THE END OF THE SECONDARY SECTION TRACK
SIMOTICS L COMBINED ADAPTER FOR FRAME SIZE 050; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; FOR INFLOW AND OUTFLOW OF WATER AND HOLDING DOWN OF COVER BAND AT THE END OF THE SECONDARY SECTION TRACK
SIMOTICS L COMBINED CROSS CONNECTOR; FRAME SIZE 050; WITH COUPLING; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; FOR WATER DISTRIBUTION AND HOLDING DOWN OF COVER BAND AT THE END OF THE SECONDARY SECTION TRACK
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; CONTINUOUS LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL SEPARATED; CABLES TIGHTLY MOUNTED;LENGTH 0,5M; POWER CABLE WITH PLUG SIZE 1; SIGNAL CABLE WITH PLUG SIZE M17; FN=150N; FMAX=260N; VMAX_FN=435M/MIN; VMAX_FMAX=242M/MIN; IN =2,8A; IMAX=5,9A; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; CONTINUOUS LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL SEPARATED; CABLES TIGHTLY MOUNTED;LENGTH 2M FN=300N; FMAX=510N; VMAX_FN=202M/MIN; VMAX=106M/MIN; IN=2,8A; IMAX=5,9A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; CONTINUOUS LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL SEPARATED; CABLES TIGHTLY MOUNTED;LENGTH 0,5M; POWER CABLE WITH PLUG SIZE 1; SIGNAL CABLE WITH PLUG SIZE M17; FN=300N; FMAX=510N; VMAX_FN=202M/MIN; VMAX_FMAX=106M/MIN; IN=2,8A; IMAX=5,9A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL SEPARATED; CABLES TIGHTLY MOUNTED;LENGTH 2M; FN=200N; FMAX=550N; VMAX_FN=373M/MIN; VMAX_FMAX=146M/MIN; IN=2,7A; IMAX=8,2A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL SEPARATED; CABLES TIGHTLY MOUNTED;LENGTH 0,5M; POWER CABLE WITH PLUG SIZE 1; SIGNAL CABLE WITH PLUG SIZE 0,5; FN=200N; FMAX=550N; VMAX_FN=373M/MIN; VMAX_FMAX=146M/MIN; IN=2,7A; IMAX=8,2A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL SEPARATED; CABLES TIGHTLY MOUNTED;LENGTH 2M; FN=200N; FMAX=550N; VMAX_FN=373M/MIN; VMAX_FMAX=146M/MIN; IN=2,7A; IMAX=8,2A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 050; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 2,5 SECONDARY SECTION SEGMENTS
SIMOTICS L COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 050; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 3 SECONDARY SECTION SEGMENTS
SIMOTICS L COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 050; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 3,5 SECONDARY SECTION SEGMENTS
SIMOTICS L COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 050; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 4 SECONDARY SECTION SEGMENTS
SIMOTICS L COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 050; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 5 SECONDARY SECTION SEGMENTS
SIMOTICS L COVER BAND FOR ONE SECONDARY SECTION TRACK; FRAME SIZE 100; COLD-ROLLED SHEET (0,4MM); PRICE PER SECONDARY SECTION SEGMENT; LENGTH IN NUMBER OF SECONDARY SECTIONS = 20 + 2
SIMOTICS L COMBINED END-PIECE FOR FRAME SIZE 100; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; FOR WATER-REDIRECTION AND HOLDING DOWN OF COVER BAND AT THE END OF THE SECONDARY SECTION TRACK
SIMOTICS L COMBINED ADAPTER FOR FRAME SIZE 100; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; FOR INFLOW AND OUTFLOW OF WATER AND HOLDING DOWN OF COVER BAND AT THE END OF THE SECONDARY SECTION TRACK