SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; COVER PREPARED FOR METRIC SCREW GLAND; SEPARATE CONNECTION OF POWER AND SIGNAL; FN=1840N; FMAX=5170N; VMAX_FN=297M/MIN; VMAX_FMAX=125M/MIN; IN=19A; IMAX=58,7A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL IN ONE CABLE; COVER IS PREPARED FOR PLASTIC CONDUIT COUPLING; FN=1840N; FMAX=5170N; VMAX_FN=297M/MIN; VMAX_FMAX=125M/MIN IN=50A; IMAX=154,9A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; COVER PREPARED FOR METRIC SCREW GLAND; SEPARATE CONNECTION OF POWER AND SIGNAL; FN=1840N; FMAX=5170N; VMAX_FN=297M/MIN; VMAX_FMAX=125M/MIN; IN=50A; IMAX=154,9A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; CONTINUOUS LOAD SPECIFICATION; SEPARATE CONNECTION OF POWER AND SIGNAL; COVER PREPARED FOR METRIC SCREW GLAND; FN=3460N; FMAX=5870N; VMAX_FN=196M/MIN; VMAX=109M/MIN; IN=28,4A; IMAX=59,6A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRECISION COOLER FOR PRIMARY SECTION 1FN3300-4W... COMPONENT 3-PHASE SYNCHRONOUS MOTOR;
SIMOTICS L PRECISION COOLER FOR PRIMARY SECTION 1FN3300-4N... COMPONENT 3-PHASE SYNCHRONOUS MOTOR;
SIMOTICS L SECONDARY SECTION FOR LINEAR MOTOR 1FN3; FRAME SIZE 300; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; LENGTH 184 MM
SIMOTICS L COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 300; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 2,5 SECONDARY SECTION SEGMENTS
SIMOTICS L COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 300; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 3 SECONDARY SECTION SEGMENTS
SIMOTICS L COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 300; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 3,5 SECONDARY SECTION SEGMENTS
SIMOTICS L COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 300; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 4 SECONDARY SECTION SEGMENTS
SIMOTICS L COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 300; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 5 SECONDARY SECTION SEGMENTS
PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL IN ONE CABLE; COVER IS PREPARED FOR PLASTIC CONDUIT COUPLING; FN=2450N; FMAX=6900N; VMAX_FN=176M/MIN; VMAX=63M/MIN; IN=16A; IMAX=49,4A
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; COVER PREPARED FOR METRIC SCREW GLAND; SEPARATE CONNECTION OF POWER AND SIGNAL; FN=2450N; FMAX=6900N; VMAX_FN=176M/MIN; VMAX_FMAX=63M/MIN; IN=16A; IMAX=49,4A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL IN ONE CABLE; COVER IS PREPARED FOR PLASTIC CONDUIT COUPLING; FN=2450N; FMAX=6900N; VMAX_FN=297M/MIN; VMAX=125M/MIN; IN=25,3A; IMAX=78,3A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; COVER PREPARED FOR METRIC SCREW GLAND; SEPARATE CONNECTION OF POWER AND SIGNAL; FN=2450N; FMAX=6900N; VMAX_FN=297M/MIN; VMAX_FMAX=125M/MIN; IN=25,3A; IMAX=78,3A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L END PIECE FOR SECONDARY UNIT WITH RETAINING DEV. FOR COVER COMPONENT 3-PHASE SYNCHRONOUS MOTOR;
SIMOTICS L COMBINED END-PIECE FOR FRAME SIZE 450; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; FOR WATER-REDIRECTION AND HOLDING DOWN OF COVER BAND AT THE END OF THE SECONDARY SECTION TRACK
SIMOTICS L COMBINED ADAPTER FOR FRAME SIZE 450; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; FOR INFLOW AND OUTFLOW OF WATER AND HOLDING DOWN OF COVER BAND AT THE END OF THE SECONDARY SECTION TRACK
SIMOTICS L COMBINED CROSS CONNECTOR; FRAME SIZE 450; WITH COUPLING; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; FOR WATER DISTRIBUTION AND HOLDING DOWN OF COVER BAND AT THE END OF THE SECONDARY SECTION TRACK
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; CONTINUOUS LOAD SPECIFICATION; COVER PREPARED FOR 2 METRIC SCREW GLAND; SEPARATE CONNECTION OF POWER AND SIGNAL; WITH FN=2595N; FMAX=4400N; VMAX_FN=191M/MIN; VMAX_FMAX=107M/MIN; IN =20,4A; IMAX=42,9A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; CONTINUOUS LOAD SPECIFICATION; SEPARATE CONNECTION OF POWER AND SIGNAL; COVER PREPARED FOR METRIC SCREW GLAND; FN=2595N; FMAX=4400N; VMAX_FN=271M/MIN; VMAX=153M/MIN; IN=28,4A; IMAX=59,6A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRECISION COOLER FOR PRIMARY SECTION 1FN3450-2W... COMPONENT 3-PHASE SYNCHRONOUS MOTOR;
SIMOTICS L PRECISION COOLER FOR PRIMARY SECTION 1FN3450-2N... COMPONENT 3-PHASE SYNCHRONOUS MOTOR;
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL IN ONE CABLE; COVER IS PREPARED FOR PLASTIC CONDUIT COUPLING; FN=1930N; FMAX=5180N; VMAX_FN=112M/MIN; VMAX=30M/MIN; IN=8,6A; IMAX=25,3A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; COVER PREPARED FOR METRIC SCREW GLAND; SEPARATE CONNECTION OF POWER AND SIGNAL; FN=1930N; FMAX=5180N; VMAX_FN=112M/MIN; VMAX_FMAX=30M/MIN; IN=8,6A; IMAX=25,3A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL IN ONE CABLE; COVER IS PREPARED FOR PLASTIC CONDUIT COUPLING; FN=1930N; FMAX=5180N; VMAX_FN=275M/MIN; VMAX=120M/MIN; IN=18,8A; IMAX=55,3A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; COVER PREPARED FOR METRIC SCREW GLAND; SEPARATE CONNECTION OF POWER AND SIGNAL; FN=1930N; FMAX=5180N; VMAX_FN=275M/MIN; VMAX_FMAX=120M/MIN; IN=18,8A; IMAX=55,3A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL IN ONE CABLE; COVER IS PREPARED FOR PLASTIC CONDUIT COUPLING; FN=1930N; FMAX=5170N; VMAX_FN=382M/MIN; VMAX=180M/MIN; IN=23,5A; IMAX=69,8A