SIMOTICS L COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 150; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 3 SECONDARY SECTION SEGMENTS
SIMOTICS L COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 150; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 3,5 SECONDARY SECTION SEGMENTS
SIMOTICS L COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 150; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 4 SECONDARY SECTION SEGMENTS
SIMOTICS L COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 150; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 5 SECONDARY SECTION SEGMENTS
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL IN ONE CABLE; COVER IS PREPARED FOR PLASTIC CONDUIT COUPLING; FN=1350N; FMAX=3300N; VMAX_FN=282M/MIN; VMAX=126M/MIN; IN=14,3A; IMAX=38,2A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; COVER PREPARED FOR METRIC SCREW GLAND; SEPARATE CONNECTION OF POWER AND SIGNAL; FN=1350N; FMAX=3300N; VMAX_FN=282M/MIN; VMAX_FMAX=126M/MIN; IN=14,3A; IMAX=38,2A
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL IN ONE CABLE; COVER IS PREPARED FOR PLASTIC CONDUIT COUPLING; FN=1690N; FMAX=4120N; VMAX_FN=282M/MIN; VMAX=126M/MIN; IN=17,9A; IMAX=47,7A
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; COVER PREPARED FOR METRIC SCREW GLAND; SEPARATE CONNECTION OF POWER AND SIGNAL; FN=1690N; FMAX=4120N; VMAX_FN=282M/MIN; VMAX_FMAX=126M/MIN; IN=17,9A; IMAX=47,7A
SIMOTICS L COMBINED END-PIECE FOR FRAME SIZE 300; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; FOR WATER-REDIRECTION AND HOLDING DOWN OF COVER BAND AT THE END OF THE SECONDARY SECTION TRACK
SIMOTICS L COMBINED ADAPTER FOR FRAME SIZE 300; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; FOR INFLOW AND OUTFLOW OF WATER AND HOLDING DOWN OF COVER BAND AT THE END OF THE SECONDARY SECTION TRACK
SIMOTICS L COMBINED CROSS CONNECTOR; FRAME SIZE 300; WITH COUPLING; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; FOR WATER DISTRIBUTION AND HOLDING DOWN OF COVER BAND AT THE END OF THE SECONDARY SECTION TRACK
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL IN ONE CABLE; COVER IS PREPARED FOR PLASTIC CONDUIT COUPLING; FN=615N; FMAX=1720N; VMAX_FN=309M/MIN; VMAX=128M/MIN; IN=6,5A; IMAX=20A
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; COVER PREPARED FOR METRIC SCREW GLAND; SEPARATE CONNECTION OF POWER AND SIGNAL; FN=615N; FMAX=1720N; VMAX_FN=309M/MIN; VMAX_FMAX=128M/MIN; IN=6,5A; IMAX=20A
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; CONTINUOUS LOAD SPECIFICATION; SEPARATE CONNECTION OF POWER AND SIGNAL; COVER PREPARED FOR METRIC SCREW GLAND; FN=1730N; FMAX=2940N; VMAX_FN=228M/MIN; VMAX=127M/MIN; IN=16,2A; IMAX=34,1A
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL IN ONE CABLE; COVER IS PREPARED FOR PLASTIC CONDUIT COUPLING; FN=1225N; FMAX=3450N; VMAX_FN=176M/MIN; VMAX=63M/MIN; IN=8A; IMAX=24,7A
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; COVER PREPARED FOR METRIC SCREW GLAND; SEPARATE CONNECTION OF POWER AND SIGNAL; FN=1225N; FMAX=3450N; VMAX_FN=176M/MIN; VMAX_FMAX=63M/MIN; IN=8A; IMAX=24,7A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL IN ONE CABLE; COVER IS PREPARED FOR PLASTIC CONDUIT COUPLING; FN=1225N; FMAX=3450N; VMAX_FN=297M/MIN; VMAX=125M/MIN; IN=12,6A; IMAX=39,2A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; COVER PREPARED FOR METRIC SCREW GLAND; SEPARATE CONNECTION OF POWER AND SIGNAL; FN=1225N; FMAX=3450N; VMAX_FN=297M/MIN; VMAX_FMAX=125M/MIN; IN=12,6A; IMAX=39,2A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL IN ONE CABLE; COVER IS PREPARED FOR PLASTIC CONDUIT COUPLING; FN=1225N; FMAX=3450N; VMAX_FN=805M/MIN; VMAX_FMAX=369M/MIN; IN=33,2A; IMAX=99,7A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; COVER PREPARED FOR METRIC SCREW GLAND; SEPARATE CONNECTION OF POWER AND SIGNAL; FN=1225N; FMAX=3450N; VMAX_FN=805M/MIN; VMAX_FMAX=369M/MIN; IN=33,2A; IMAX=99,7A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; CONTINUOUS LOAD SPECIFICATION; SEPARATE CONNECTION OF POWER AND SIGNAL; COVER PREPARED FOR METRIC SCREW GLAND;; FN=2595N; FMAX=4400N; VMAX_FN=257M/MIN; VMAX=144M/MIN; IN=27,3A; IMAX=57,4A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL IN ONE CABLE; COVER IS PREPARED FOR PLASTIC CONDUIT COUPLING; FN=1840N; FMAX=5170N; VMAX_FN=297M/MIN; VMAX=125M/MIN; IN=19A; IMAX=58,7A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.