SICK

Image
Part Number
Description
Specification: Part Number 6038017 Connection type: M20x1,5 ATEX certification: - Probe length: 220 mm Signal voltage LOW: < 1 V Initialization time: 2 s Output current: < 300 mA Accuracy: ± 10 mm Measurement: Switch Response time: 500 ms Ripple:
Specification: Part Number 6038020 Output current: < 300 mA VDE protection class 2: + Measurement: Switch Connection type: ½" NPT Probe length: 220 mm Ripple:
Specification: Part Number 6038016 Repeatability: ± 5 mm Power consumption: < 10 mA Ambient storage temperature: -40 °C ... 80 °C Measurement: Switch Process pressure: -1 bar ... 25 bar Signal voltage LOW: < 1 V Switching output: Transistor output PNP/ NPN: 10 V DC ... 55 V DC VDE protection class 2: + Hysteresis: 10 mm Housing material: Plastic Accuracy: ± 10 mm Inductive load: 1 H
Specification: Part Number 6039278 Medium: Bulk solids ATEX certification: - Inductive load: 1 H Process connection: G 1½ A PN 25 / 316L Enclosure rating: IP 66 Sensor material: Stainless steel 1.4404 Measurement: Switch Ambient storage temperature: -40 °C ... 80 °C Initialization time: 2 s Particle size: < 10 mm Ambient operating temperature: -40 °C ... 80 °C Connection type: M20x1,5
Specification: Part Number 6041250 Housing material: Aluminum Process pressure: -1 bar ... 25 bar Power consumption: 5 mA ... 30 mA Fill material density: 0.008 g/cm Inductive load: 750 VA 54 W Probe length: 220 mm Capacitive load: 750 VA 54 W VDE protection class 1: + Process connection: Flange DN 100 PN 6 Form C, DIN2501/ 316L Connection type: M20x1,5 Particle size: < 10 mm ATEX certification
Specification: Part Number 6044863 Ambient temperature operation: -40 °C ... 70 °C Repeatability: &le; 5 mm Process pressure: -1 bar ... 16 bar Output signal: Contactless electronic switch: 20 V AC/DC ... 253 V DC VDE protection class 1: + Ambient storage temperature: -40 °C ... 80 °C Process connection: G 1 A Housing material: Plastic Output current: < 400 mA Enclosure rating: IP 66 / IP 67, IP 6
Specification: Part Number 6044866 ATEX certification: - Output current: 1 mA / 2,5 mA Response time: 500 ms when covered / 1000 ms when uncovered Housing material: Plastic Power consumption: 1 mA / 2,5 mA Medium: Bulk solids Repeatability: &le; 5 mm Sensor material: Stainless steel 316L, 318S Process connection: G 1 A Output signal: NAMUR signal: 4.5 V DC ... 12 V DC Ambient temperature operation:
Specification: Part Number 6044864 Response time: 500 ms when covered / 1000 ms when uncovered Accuracy of sensor element: ± 10 mm Output signal: Double relay (DPDT): 20 V DC ... 72 V DC / 20 ... 253 V AC Medium: Bulk solids Connection type: M20 x 1.5 Process connection: G 1 A Power consumption: 5 mA ... 30 mA VDE protection class 1: + Enclosure rating: IP 66 / IP 67, IP 66 / IP 68 (0.2 bar) Ambient st
Specification: Part Number 6044865 Enclosure rating: IP 66 / IP 67, IP 66 / IP 68 (0.2 bar) Response time: 500 ms when covered / 1000 ms when uncovered Output signal: Transistor output PNP/ NPN: 10 V DC ... 55 V DC Medium: Bulk solids Process temperature: -50 °C ... 150 °C Initialization time: < 2 s ATEX certification: - Measurement: Switch Process connection: G 1 A Output current: < 300 mA Ambi
Specification: Part Number 6044870 Ambient temperature operation: -40 °C ... 70 °C Housing material: Plastic Capacitive load: 100 nF Medium: Bulk solids Process connection: G 1 A Tensile strength: &le; 3,000 N Process pressure: -1 bar ... 6 bar Response time: 500 ms when covered / 1000 ms when uncovered Output current: < 300 mA Process temperature: -20 °C ... 80 °C VDE protection class 2: +
Specification: Part Number 1045046 PROFIBUS DP: - Dimensions: 94 mm x 165 mm x 88 mm Scanning frequency: 12.5 Hz ... 50 Hz DeviceNet: - Power consumption: 8 W Function (CAN bus): Auxiliary interface Field of view: 85 °, operating angle with 4 measurement layers, 25° work area expansion with 2 measurement layers (total 110°) Enclosure rating: IP 69K CAN bus: + Systematic error : ± 300 mm Field of
Specification: Part Number 6040950 Pressure type: Gauge pressure Measuring range: 0 bar ... 1 bar Dielectric strength: 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) Temperature coefficient in rated temperature range: Mean TC of span &le; 0.2 % of span / 10 K, Mean TC of zero: &le; 0.2 % of span / 10 K ( < 0.4 % for pressure ranges &le; 0.25 bar) Rated temperature
Specification: Part Number 6040951 Non-linearity: &le; ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) Accuracy:
Specification: Part Number 6040952 Measuring range: 0 bar ... 1 bar Long-term drift/one-year stability: &le; ± 0.2 % Of span (at reference conditions) Dielectric strength: 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) CE-conformity: + CE-conformity: EMC directive: 2004/108/EC, EN 61 326-2-3 Enclosure rating: IP 68 Weight cable: 0.08 kg/m Supply voltag
Specification: Part Number 6040953 Non-repeatability: &le; ± 0.1 % of span Rated temperature range: 0 °C ... 50 °C CE-conformity: + Wetted parts: Pressure connection/ diaphragm: Stainless steel, Housing: Stainless steel, Protection cap: PA Enclosure rating: IP 68 Pressure type: Gauge pressure Connection type: Cable PUR Long-term drift/one-year stability: &le; ± 0.2 % Of span (at reference conditions) No
Specification: Part Number 6040954 Temperature coefficient in rated temperature range: Mean TC of span &le; 0.2 % of span / 10 K, Mean TC of zero: &le; 0.2 % of span / 10 K ( < 0.4 % for pressure ranges &le; 0.25 bar) CE-conformity: + Pressure type: Gauge pressure Connection type: Cable PUR Output signal: 4...20 mA Process temperature: -10 °C ... 50 °C Dielectric strength: 500 V DC, NEC Class 02 power supply (l
Specification: Part Number 6040955 Non-repeatability: &le; ± 0.1 % of span Enclosure rating: IP 68 Long-term drift/one-year stability: &le; ± 0.2 % Of span (at reference conditions) Temperature coefficient in rated temperature range: Mean TC of span &le; 0.2 % of span / 10 K, Mean TC of zero: &le; 0.2 % of span / 10 K ( < 0.4 % for pressure ranges &le; 0.25 bar) CE-conformity: + Weight sensor: 0.18 kg Wetted par
Specification: Part Number 6040957 CE-conformity: + Electrical safety: Short-circuit protection: QA towards M, Protection class: III, Surge protection: According to EN 61000-4-5 (1.5 J) optional for enhanced varient, Reverse polarity protection: L+ towards M Temperature coefficient in rated temperature range: Mean TC of span &le; 0.2 % of span / 10 K, Mean TC of zero: &le; 0.2 % of span / 10 K ( < 0.4 % for pressure ranges &le;
Specification: Part Number 6040938 Connection type: Cable PUR Protection class III: + Weight sensor: 0.18 kg Measuring range: 0 bar ... 0.25 bar Supply voltage: 10 V DC ... 30 V DC Pressure type: Gauge pressure Electrical safety: Short-circuit protection: QA towards M, Protection class: III, Surge protection: According to EN 61000-4-5 (1.5 J) optional for enhanced varient, Reverse polarity protection: L+ towards M
Specification: Part Number 6040940 Weight cable: 0.08 kg/m Measuring range: 0 bar ... 0.25 bar Supply voltage: 10 V DC ... 30 V DC Long-term drift/one-year stability: &le; ± 0.2 % Of span (at reference conditions) Rated temperature range: 0 °C ... 50 °C Storage temperature: -30 °C ... 80 °C Weight sensor: 0.18 kg Protection class III: + Dielectric strength: 500 V DC, NEC Class 02 power supply (low vol
Specification: Part Number 6040941 Non-linearity: &le; ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) CE-conformity: EMC directive: 2004/108/EC, EN 61 326-2-3 Process temperature: -10 °C ... 50 °C Enclosure rating: IP 68 Connection type: Cable PUR Supply voltage: 10 V DC ... 30 V DC Temperature coefficient in rated temperature range: Mean TC of span &le; 0.2 % of span / 10 K, Mean TC
Specification: Part Number 6040943 Weight sensor: 0.18 kg Storage temperature: -30 °C ... 80 °C CE-conformity: EMC directive: 2004/108/EC, EN 61 326-2-3 Dielectric strength: 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) Non-linearity: &le; ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) Supply voltage: 10 V DC ... 30 V DC Conne
Specification: Part Number 6040944 Temperature coefficient in rated temperature range: Mean TC of span &le; 0.2 % of span / 10 K, Mean TC of zero: &le; 0.2 % of span / 10 K ( < 0.4 % for pressure ranges &le; 0.25 bar) Connection type: Cable PUR Non-linearity: &le; ± 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) Long-term drift/one-year stability: &le; ± 0.2 % Of span (at reference conditions) S
Specification: Part Number 6040945 Measuring range: 0 bar ... 0.4 bar Supply voltage: 10 V DC ... 30 V DC Process temperature: -10 °C ... 50 °C Connection type: Cable PUR Protection class III: + Pressure type: Gauge pressure Accuracy:
Specification: Part Number 6040947 Temperature coefficient in rated temperature range: Mean TC of span &le; 0.2 % of span / 10 K, Mean TC of zero: &le; 0.2 % of span / 10 K ( < 0.4 % for pressure ranges &le; 0.25 bar) Electrical safety: Short-circuit protection: QA towards M, Protection class: III, Surge protection: According to EN 61000-4-5 (1.5 J) optional for enhanced varient, Reverse polarity protection: L+ towards M Non-repe
Specification: Part Number 6040949 Weight sensor: 0.18 kg Weight cable: 0.08 kg/m CE-conformity: + Non-repeatability: &le; ± 0.1 % of span Pressure type: Gauge pressure Temperature coefficient in rated temperature range: Mean TC of span &le; 0.2 % of span / 10 K, Mean TC of zero: &le; 0.2 % of span / 10 K ( < 0.4 % for pressure ranges &le; 0.25 bar) Connection type: Cable PUR Enclosure rating: IP 68 Proce
Specification: Part Number 6040970 Accuracy:
Specification: Part Number 1060171 Lower signal level: 3.8 mA ... 4 mA MTTF: 194.3 a (EN ISO 13849-1) Process temperature: -20 °C ... +100 °C RoHS certificate: + Hysteresis: Min. 2 mm, free adjustable Initialization time: &le; 5 s IO-Link: + Medium: Fluids Signal voltage LOW: &le; 2 V Supply voltage: 12 V DC ... 30 V DC Protection class: III Temperature drift: < 0.1 mm/K Probe type: Wit
Specification: Part Number 1057073 Dielectricity constant: &ge; 1.8 with coaxial tube, &ge; 5 for mono rod probe / rope probe Output current: < 100 mA Hysteresis: Min. 2 mm, free adjustable MTTF: 194.3 a (EN ISO 13849-1) Medium: Fluids Signal voltage HIGH: Vs - 2 V Max.probe load: 6 Nm Process temperature: -20 °C ... +100 °C Upper signal level: 20 mA ... 20.5 mA Output load: 0 V ... 10 V > 750 Ohm 
Specification: Part Number 1062245 Protection class: III Accuracy of sensor element: ± 5 mm Response time: < 400 ms Ambient storage temperature: -40 °C ... +80 °C Output current: < 100 mA Max.probe load: 6 Nm Inductive load: < 1 H Process pressure: -1 bar ... 10 bar Signal voltage LOW: &le; 2 V Output signal: 1 PNP transistor output (Q1) und 3 PNP / NPN transistor output (Q2...Q4) switchable, 4
Menu
Mail Us
enquiry@onstocktrading.com