Specification: Part Number 1056299 Housing material: 303 Wetted parts: 316L (Ra ≤ 0,8 µm), PEEK UL approval: + MTTF: 194.3 a (EN ISO 13849-1) Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono probe Process connection: G ¾ A Output current: < 100 mA Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 400 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 13,5 V Process temperature: -20 °C ... +150 °C Response time: < 400 ms Ambient storage temperature: -40 °C ... +80 °C Interference resistance: EN 61000-6-2:2005 EMC: EN 61326-1:2006, 2004/108/EG Resolution: < 2 mm Signal voltage HIGH: Vs - 2 V Signal voltage LOW: ≤ 2 V Measurement: Switch, Continuous Ambient temperature operation: -20 °C ... +60 °C Supply voltage: 12 V DC ... 30 V DC Connection type: Round connector M12 x 1, 5-pin Process pressure: -1 bar ... 16 bar Interference emission: EN 61000-6-4:2007 Repeatability: ≤ 2 mm Conductivity: No limitation Housing design: With closed cover IO-Link: + Power consumption: ≤ 75 mA at 24 V DC without output load Upper signal level: 20 mA ... 20.5 mA Inductive load: < 1 H Lower signal level: 3.8 mA ... 4 mA Medium: Fluids RoHS certificate: + Hysteresis: Min. 2 mm, free adjustable Inactive area at process connector: 25 mm Enclosure rating: IP 67: EN 60529, IP 69K: EN 40050 Accuracy of sensor element: ± 5 mm Single- and continuous shock: EN 60068-2-27 Capacitive load: 100 nF Initialization time: ≤ 2 s Inactive area at probe end: 10 mm 3-A: - Temperature drift: < 0.1 mm/K Probe length: 1,700 mm Max.probe load: 6 Nm Protection class: III EHEDG approval: + GOST approval: +