Specification: Part Number 1056300 Medium: Fluids Signal voltage HIGH: Vs - 2 V Hysteresis: Min. 2 mm, free adjustable RoHS certificate: + Probe length: 1,800 mm MTTF: 194.3 a (EN ISO 13849-1) Output current: < 100 mA Upper signal level: 20 mA ... 20.5 mA Wetted parts: 316L (Ra ≤ 0,8 µm), PEEK Enclosure rating: IP 67: EN 60529, IP 69K: EN 40050 EMC: EN 61326-1:2006, 2004/108/EG GOST approval: + Housing design: With closed cover Interference emission: EN 61000-6-4:2007 Housing material: 303 Protection class: III Inductive load: < 1 H Process connection: G ¾ A Repeatability: ≤ 2 mm Supply voltage: 12 V DC ... 30 V DC UL approval: + 3-A: - Measurement: Switch, Continuous Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono probe Ambient temperature operation: -20 °C ... +60 °C Max.probe load: 6 Nm Process temperature: -20 °C ... +150 °C Capacitive load: 100 nF IO-Link: + Temperature drift: < 0.1 mm/K Response time: < 400 ms Interference resistance: EN 61000-6-2:2005 Resolution: < 2 mm Initialization time: ≤ 2 s Lower signal level: 3.8 mA ... 4 mA Signal voltage LOW: ≤ 2 V Power consumption: ≤ 75 mA at 24 V DC without output load Conductivity: No limitation EHEDG approval: + Accuracy of sensor element: ± 5 mm Process pressure: -1 bar ... 16 bar Ambient storage temperature: -40 °C ... +80 °C Inactive area at process connector: 25 mm Single- and continuous shock: EN 60068-2-27 Connection type: Round connector M12 x 1, 5-pin Inactive area at probe end: 10 mm Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 400 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 13,5 V