Specification: Part Number 1071147 Single- and continuous shock: EN 60068-2-27 Output current: < 100 mA Probe length: 1,000 mm Repeatability: ≤ 2 mm Ambient temperature coaxial cable: -20 °C ... +60 °C Inductive load: < 1 H Resolution: < 2 mm Conductivity: No limitation Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 400 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 13,5 V Ambient temperature operation: -20 °C ... +60 °C Temperature drift: < 0.1 mm/K Supply voltage: 12 V DC ... 30 V DC Connection type: Round connector M12 x 1, 5-pin Signal voltage HIGH: Vs - 2 V Power consumption: ≤ 75 mA at 24 V DC without output load Ambient storage temperature: -40 °C ... +80 °C Wetted parts: 316L (Ra ≤ 0,8 µm), PEEK Length coaxial cable: 3.3 m, FEP Process temperature: -20 °C ... +180 °C Accuracy of sensor element: ± 5 mm Housing material: 303 Lower signal level: 3.8 mA ... 4 mA UL approval: + Inactive area at probe end: 10 mm Max.probe load: 6 Nm Capacitive load: 100 nF Response time: < 400 ms Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono probe Interference resistance: EN 61000-6-2:2005 EMC: EN 61326-1:2006, 2004/108/EG Hysteresis: Min. 2 mm, free adjustable Signal voltage LOW: ≤ 2 V 3-A: - Initialization time: ≤ 2 s Medium: Fluids RoHS certificate: + Inactive area at process connector: 25 mm Interference emission: EN 61000-6-4:2007 EHEDG approval: + IO-Link: + Upper signal level: 20 mA ... 20.5 mA MTTF: 194.3 a (EN ISO 13849-1) Process pressure: -1 bar ... 16 bar Process connection: ¾" NPT GOST approval: + Enclosure rating: IP 67: EN 60529, IP 69K: EN 40050 Measurement: Switch, Continuous Housing design: With closed cover Protection class: III