Specification: Part Number 1071137 Signal voltage HIGH: Vs - 2 V 3-A: - Single- and continuous shock: EN 60068-2-27 Ambient temperature coaxial cable: -20 °C ... +60 °C Max.probe load: 6 Nm Capacitive load: 100 nF EHEDG approval: + Interference resistance: EN 61000-6-2:2005 Inactive area at probe end: 10 mm GOST approval: + Protection class: III Length coaxial cable: 2 m, FEP Process temperature: -20 °C ... +180 °C MTTF: 194.3 a (EN ISO 13849-1) Signal voltage LOW: ≤ 2 V Process connection: ¾" NPT Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 400 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 13,5 V Housing material: 303 Repeatability: ≤ 2 mm Inactive area at process connector: 25 mm Power consumption: ≤ 75 mA at 24 V DC without output load Upper signal level: 20 mA ... 20.5 mA Output current: < 100 mA Ambient temperature operation: -20 °C ... +60 °C UL approval: + Interference emission: EN 61000-6-4:2007 Connection type: Round connector M12 x 1, 5-pin Wetted parts: 316L (Ra ≤ 0,8 µm), PEEK Probe length: 1,000 mm IO-Link: + Medium: Fluids Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono probe Response time: < 400 ms Accuracy of sensor element: ± 5 mm EMC: EN 61326-1:2006, 2004/108/EG Conductivity: No limitation Ambient storage temperature: -40 °C ... +80 °C Resolution: < 2 mm RoHS certificate: + Process pressure: -1 bar ... 16 bar Hysteresis: Min. 2 mm, free adjustable Lower signal level: 3.8 mA ... 4 mA Enclosure rating: IP 67: EN 60529, IP 69K: EN 40050 Housing design: With PMMA viewing window Temperature drift: < 0.1 mm/K Inductive load: < 1 H Supply voltage: 12 V DC ... 30 V DC Measurement: Switch, Continuous Initialization time: ≤ 2 s