SICK - Universal pressure sensor PBS

Image
Part Number
Description
Specification: Part Number 6043792 Pressure type: Absolute pressure Weight sensor: Ca. 200 g Compound pressure: -1 bar ... 0 bar up to -1 bar ... +24 bar Shock load: 50 g according to IEC 60068-2-27 (mechanical shock) Power consumption: 45 mA (for configurations without analog output signal), 70 mA (for configurations with analog output signal) Vibration load: 10 g according to IEC 60068-2-6 (vibration under resonance
Specification: Part Number 6043465 Weight sensor: Ca. 200 g Output signal: 2 x PNP Storage temperature: -20 °C ... +80 °C Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M, Protection class: III, Overvoltage protection: 40 V DC, Reverse polarity protection: L+ towards M Service life: Minimum 100 Mio. life cycles Wetted parts: Pressure connection: stainless steel 316L, Pressure sensor: stainless steel
Specification: Part Number 6050283 CE-conformity: Pressure equipment directive: This instrument is a pressure accessory as defined by the directive 97/23/EC, EMC directive: 2004/108/EC, EN 61326-2-3 Isolation voltage: 500 V DC Temperature coefficient in rated temperature range: Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.2% of span / 10 K Vibration load: 10 g according to IEC 60068-2-6 (vibration under
Specification: Part Number 6039775 Response time: 3 ms Internal transmission fluid: Silicone oil (only with pressure ranges < 0 bar ... 10 bar and &le; 0 bar abs ... 25 bar abs) Ambient temperature: -20 °C ... +80 °C Weight sensor: Ca. 200 g Medium: Liquid and gaseous media Compound pressure: -1 bar ... 0 bar up to -1 bar ... +24 bar Power consumption: 45 mA (for configurations without analog output signal), 70
Specification: Part Number 6038930 Process connection: G ½ B according to EN 837 Gauge pressure: 0 bar ... 1 bar up to bar ... 600 bar Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M, Protection class: III, Overvoltage protection: 40 V DC, Reverse polarity protection: L+ towards M Process temperature: -20 °C ... +85 °C Vibration load: 10 g according to IEC 60068-2-6 (vibration under resonance) Mea
Specification: Part Number 6041233 Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M, Protection class: III, Overvoltage protection: 40 V DC, Reverse polarity protection: L+ towards M Internal transmission fluid: Silicone oil (only with pressure ranges < 0 bar ... 10 bar and &le; 0 bar abs ... 25 bar abs) Enclosure rating: IP 67 Compound pressure: -1 bar ... 0 bar up to -1 bar ... +24 bar Long-term drift/o
Specification: Part Number 6038870 Weight sensor: Ca. 200 g Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M, Protection class: III, Overvoltage protection: 40 V DC, Reverse polarity protection: L+ towards M Power consumption: 45 mA (for configurations without analog output signal), 70 mA (for configurations with analog output signal) Accuracy: &le; ± 1 % of span, (Including non-linearity, hysteresis, zero p
Specification: Part Number 6038896 Seal: NBR Storage temperature: -20 °C ... +80 °C Output signal: 1 x PNP + 4 mA ... 20 mA Enclosure rating: IP 67 Shock load: 50 g according to IEC 60068-2-27 (mechanical shock) Display: 14-segment-LED, blue, 4-digits, height 9 mm, electronically turnable by 180°, Update: 1,000, 500, 200, 100 ms (adjustable), Accuracy: &le; 1 % of span ± 1 digit Total current consumption: Max.
Specification: Part Number 6041541 Service life: Minimum 100 Mio. life cycles Zero point adjustment: Max. + 3 % of span Shock load: 50 g according to IEC 60068-2-27 (mechanical shock) Pressure type: Compound pressure Total current consumption: Max. 350 mA / 570 mA (incl. switching current) Non-linearity: &le; ± 0.5 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) Connection type: Round connecto
Specification: Part Number 6041614 Compound pressure: -1 bar ... 0 bar up to -1 bar ... +24 bar Protection class III: + Gauge pressure: 0 bar ... 1 bar up to bar ... 600 bar Zero point adjustment: Max. + 3 % of span Measuring range: -1 bar ... 9 bar Isolation voltage: 500 V DC Enclosure rating: IP 67 Storage temperature: -20 °C ... +80 °C Rated temperature range: 0 °C ... +80 °C Weight sensor: Ca.
Specification: Part Number 6049699 Rated temperature range: 0 °C ... +80 °C Long-term drift/one-year stability: &le; 0.2 % of span according to IEC 61298-2 Enclosure rating: IP 67 Weight sensor: Ca. 200 g Process temperature: -20 °C ... +85 °C Pressure type: Compound pressure Internal transmission fluid: Silicone oil (only with pressure ranges < 0 bar ... 10 bar and &le; 0 bar abs ... 25 bar abs) Zero poin
Specification: Part Number 6038871 Long-term drift/one-year stability: &le; 0.2 % of span according to IEC 61298-2 Temperature coefficient in rated temperature range: Mean TC of span &le; 0.2 % of span / 10 K, Mean TC of zero: &le; 0.2% of span / 10 K Output signal: 2 x PNP Process temperature: -20 °C ... +85 °C Measuring range: -1 bar ... 24 bar Setting accuracy of switching outputs: &le; ± 0.5 % of span Servic
Specification: Part Number 6038897 Power consumption: 45 mA (for configurations without analog output signal), 70 mA (for configurations with analog output signal) Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M, Protection class: III, Overvoltage protection: 40 V DC, Reverse polarity protection: L+ towards M Process temperature: -20 °C ... +85 °C Connection type: Round connector M12 x 1, 4-pin, IP 67 R
Specification: Part Number 6038911 Temperature coefficient in rated temperature range: Mean TC of span &le; 0.2 % of span / 10 K, Mean TC of zero: &le; 0.2% of span / 10 K Weight sensor: Ca. 200 g Gauge pressure: 0 bar ... 1 bar up to bar ... 600 bar Measuring range: -1 bar ... 24 bar Non-linearity: &le; ± 0.5 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) Display: 14-segment-LED, blue, 4-digits
Specification: Part Number 6038868 Zero point adjustment: Max. + 3 % of span Response time: 3 ms Storage temperature: -20 °C ... +80 °C Compound pressure: -1 bar ... 0 bar up to -1 bar ... +24 bar Connection type: Round connector M12 x 1, 4-pin, IP 67 Process temperature: -20 °C ... +85 °C Display: 14-segment-LED, blue, 4-digits, height 9 mm, electronically turnable by 180°, Update: 1,000, 500, 200, 100 ms (a
Specification: Part Number 6038894 Shock load: 50 g according to IEC 60068-2-27 (mechanical shock) Output signal: 1 x PNP + 4 mA ... 20 mA Process temperature: -20 °C ... +85 °C CE-conformity: Pressure equipment directive: This instrument is a pressure accessory as defined by the directive 97/23/EC, EMC directive: 2004/108/EC, EN 61326-2-3 Weight sensor: Ca. 200 g Long-term drift/one-year stability: &le; 0.2 % of sp
Specification: Part Number 6044603 Total current consumption: Max. 350 mA / 570 mA (incl. switching current) CE-conformity: Pressure equipment directive: This instrument is a pressure accessory as defined by the directive 97/23/EC, EMC directive: 2004/108/EC, EN 61326-2-3 Pressure port: Standard Pressure type: Compound pressure Shock load: 50 g according to IEC 60068-2-27 (mechanical shock) Vibration load: 10 g accord
Specification: Part Number 6038919 Enclosure rating: IP 67 Rated temperature range: 0 °C ... +80 °C Rotatable housing: Display against housing with electrical connection: 330 °, Housing against process connection: 320 ° Process temperature: -20 °C ... +85 °C Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M, Protection class: III, Overvoltage protection: 40 V DC, Reverse polarity protection: L+ towar
Specification: Part Number 6038856 Temperature coefficient in rated temperature range: Mean TC of span &le; 0.2 % of span / 10 K, Mean TC of zero: &le; 0.2% of span / 10 K Rotatable housing: Display against housing with electrical connection: 330 °, Housing against process connection: 320 ° Seal: Copper Display: 14-segment-LED, blue, 4-digits, height 9 mm, electronically turnable by 180°, Update: 1,000, 500, 200, 100 ms (a
Specification: Part Number 6038881 Seal: Copper Ambient temperature: -20 °C ... +80 °C Protection class III: + Connection type: Round connector M12 x 1, 4-pin, IP 67 Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M, Protection class: III, Overvoltage protection: 40 V DC, Reverse polarity protection: L+ towards M Shock load: 50 g according to IEC 60068-2-27 (mechanical shock) Rated temperature ran
Specification: Part Number 6038908 Rated temperature range: 0 °C ... +80 °C Zero point adjustment: Max. + 3 % of span Process temperature: -20 °C ... +85 °C Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M, Protection class: III, Overvoltage protection: 40 V DC, Reverse polarity protection: L+ towards M Medium: Liquid and gaseous media Output signal: 2 x PNP + 4 mA ... 20 mA Pressure type: Com
Specification: Part Number 6050312 Power consumption: 45 mA (for configurations without analog output signal), 70 mA (for configurations with analog output signal) Internal transmission fluid: Silicone oil (only with pressure ranges < 0 bar ... 10 bar and &le; 0 bar abs ... 25 bar abs) Relative humidity: &le; 90 % Storage temperature: -20 °C ... +80 °C Setting accuracy of switching outputs: &le; ± 0.5 % of span Res
Specification: Part Number 6038869 Temperature coefficient in rated temperature range: Mean TC of span &le; 0.2 % of span / 10 K, Mean TC of zero: &le; 0.2% of span / 10 K Rated temperature range: 0 °C ... +80 °C Accuracy: &le; ± 1 % of span, (Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement according to IEC 61298-2)) Medium: Liquid and gaseous media Connection ty
Specification: Part Number 6049071 Connection type: Round connector M12 x 1, 4-pin, IP 67 Output signal: 2 x PNP Shock load: 50 g according to IEC 60068-2-27 (mechanical shock) Measuring range: 0 bar ... 10 bar Rotatable housing: Display against housing with electrical connection: 330 °, Housing against process connection: 320 ° Storage temperature: -20 °C ... +80 °C Medium: Liquid and gaseous media CE-conf
Specification: Part Number 6049686 Connection type: Round connector M12 x 1, 4-pin, IP 67 Weight sensor: Ca. 200 g Service life: Minimum 100 Mio. life cycles Zero point adjustment: Max. + 3 % of span Rotatable housing: Display against housing with electrical connection: 330 °, Housing against process connection: 320 ° Output signal: 1 x PNP + 4 mA ... 20 mA Long-term drift/one-year stability: &le; 0.2 % of span
Specification: Part Number 6049102 Enclosure rating: IP 67 Zero point adjustment: Max. + 3 % of span Response time: 3 ms Non-linearity: &le; ± 0.5 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) Medium: Liquid and gaseous media Output signal: 2 x PNP + 4 mA ... 20 mA Relative humidity: &le; 90 % Shock load: 50 g according to IEC 60068-2-27 (mechanical shock) Housing material: Display w
Specification: Part Number 6038862 Relative humidity: &le; 90 % Protection class III: + Connection type: Round connector M12 x 1, 4-pin, IP 67 Process temperature: -20 °C ... +85 °C Pressure port: Standard Compound pressure: -1 bar ... 0 bar up to -1 bar ... +24 bar Temperature coefficient in rated temperature range: Mean TC of span &le; 0.2 % of span / 10 K, Mean TC of zero: &le; 0.2% of span / 10 K Wetted p
Specification: Part Number 6038678 Non-linearity: &le; ± 0.5 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) Seal: NBR Response time: 3 ms Rated temperature range: 0 °C ... +80 °C Pressure type: Gauge pressure Compound pressure: -1 bar ... 0 bar up to -1 bar ... +24 bar Pressure port: Standard Long-term drift/one-year stability: &le; 0.2 % of span according to IEC 61298-2 Internal tra
Specification: Part Number 6039110 Zero point adjustment: Max. + 3 % of span Power consumption: 45 mA (for configurations without analog output signal), 70 mA (for configurations with analog output signal) Long-term drift/one-year stability: &le; 0.2 % of span according to IEC 61298-2 Service life: Minimum 100 Mio. life cycles Pressure type: Gauge pressure Storage temperature: -20 °C ... +80 °C Protection class I
Menu
Mail Us
enquiry@onstocktrading.com