SICK - SICK Encoder

Image
Part Number
Description
Specification: Part Number 1035177 Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 mm Max. number of steps per revolution: 4,096 Operating power consumption (no load): 90 mA Working temperature range: -20 °C ... 85 °C Bearing lifetime: 3.6 x 10^9 revolutions Mechanical interface: Through hollow shaft Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm Start up torque: 2.2 Ncm EMC
Specification: Part Number 1032820 Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Mass: 0.3 kg Shaft diameter: 6 mm Storage temperature range: -40 °C ... 100 °C Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Resistance to shocks: 50 g (according to EN 60068-2-27) Enclosure rating: IP 65 (according to IEC 60529), with mating connector fitted
Specification: Part Number 1031739 Storage temperature range: -40 °C ... 100 °C Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Operating torque: 0.2 Ncm Enclosure rating: IP 65 (according to IEC 60529), with mating connector fitted Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Electrical interface: Connector M23, 21-pin, radial EMC: (accor
Specification: Part Number 1034664 Max. number of revolutions: 1 Resistance to shocks: 50 g (according to EN 60068-2-27) Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Operation of zero-set: ≥ 100 ms Mass: 0.3 kg Measuring step deviation: 0.005 °, 0.016 ° Permissible Load capacity of shaft: 10 N (axial), 20 N (radial) EMC: (according to EN 61000-6-2 and EN 61000-6-3) Wo
Specification: Part Number 1035419 Working temperature range: -20 °C ... 85 °C Measuring step deviation: 0.005 °, 0.016 ° Storage temperature range: -40 °C ... 100 °C Max. number of revolutions: 1 Resolution power: 15 x 1 Shaft diameter: 6 mm Max. angular acceleration: 500,000 rad/s² Operating power consumption (no load): 90 mA Repeat accuracy: 0.005 ° Bearing lifetime: 3.6 x 10^9 revolutions
Specification: Part Number 1031736 Resistance to shocks: 50 g (according to EN 60068-2-27) Initialization time: 80 ms EMC: (according to EN 61000-6-2 and EN 61000-6-3) Operation of zero-set: ≥ 100 ms Shaft diameter: 6 mm Enclosure rating: IP 65 (according to IEC 60529), with mating connector fitted Measuring step deviation: 0.005 °, 0.016 ° Max. number of steps per revolution: 1,024 Mechanical inter
Specification: Part Number 1035372 Operating voltage range: 10 V DC ... 32 V DC Permissible Load capacity of shaft: 10 N (axial), 20 N (radial) Initialization time: 80 ms Enclosure rating: IP 66 (according to IEC 60529) Storage temperature range: -40 °C ... 100 °C EMC: (according to EN 61000-6-2 and EN 61000-6-3) Resistance to shocks: 50 g (according to EN 60068-2-27) Resistance to vibration: 20 g, 10 Hz .
Specification: Part Number 1031731 Max. angular acceleration: 500,000 rad/s² Mechanical interface: Solid shaft, Servo flange Bearing lifetime: 3.6 x 10^9 revolutions MTTFd: mean time to dangerous failure: 300 a (EN ISO 13849-1) Measuring step: 360 ° /number of lines Resistance to shocks: 50 g (according to EN 60068-2-27) Repeat accuracy: 0.005 ° Storage temperature range: -40 °C ... 100 °C Max. number
Specification: Part Number 1031723 EMC: According to EN 61000-6-2 and EN 61000-6-3 Error limits: 0.035 ° (binary number of steps) 0.046 ° (non-binary number of steps) Operating torque: 0.3 Ncm Measuring step deviation: 0.005 °, 0.016 ° Resistance to shocks: 50 g (according to EN 60068-2-27) Storage temperature range: -40 °C ... 100 °C Operating voltage range: 10 V DC ... 32 V DC Shaft diameter: 10 mm
Specification: Part Number 1031724 Bearing lifetime: 3.6 x 10^9 revolutions Working temperature range: -20 °C ... 85 °C Mechanical interface: Solid shaft, Face mount flange Max. number of revolutions: 1 Error limits: 0.035 ° (binary number of steps) 0.046 ° (non-binary number of steps) Operating torque: 0.3 Ncm Moment of inertia of the rotor: 54 gcm² EMC: According to EN 61000-6-2 and EN 61000-6-3 Ope
Specification: Part Number 1031725 Start up torque: 0.4 Ncm Enclosure rating: IP 65, according to IEC 60529, with mating connector fitted Measuring step: 360 ° /number of lines Working temperature range: -20 °C ... 85 °C Moment of inertia of the rotor: 54 gcm² Mechanical interface: Solid shaft, Face mount flange Operating power consumption (no load): 90 mA Resolution power: 100 x 1 Error limits: 0.03
Specification: Part Number 1035694 Storage temperature range: -40 °C ... 100 °C Permissible Load capacity of shaft: 20 N (radial) 10 N (axial) Enclosure rating: IP 65, according to IEC 60529, with mating connector fitted Measuring step deviation: 0.005 °, 0.016 ° Mechanical interface: Solid shaft, Face mount flange Repeat accuracy: 0.005 ° Permissible relative humidity: 90 % (condensation of the optical sca
Specification: Part Number 1031726 Maximum operating speed: 10,000 /min (without shaft seal) 6,000 /min (with shaft seal) Resistance to shocks: 50 g (according to EN 60068-2-27) Operation of zero-set: ≥ 100 ms Permissible Load capacity of shaft: 20 N (radial) 10 N (axial) Operating torque: 0.3 Ncm Max. angular acceleration: 500,000 rad/s² Storage temperature range: -40 °C ... 100 °C Max. number of revol
Specification: Part Number 1033845 Measuring step: 360 ° /number of lines Measuring step deviation: 0.005 °, 0.016 ° Shaft diameter: 10 mm Start up torque: 0.4 Ncm Resolution power: 400 x 1 Moment of inertia of the rotor: 54 gcm² Resistance to shocks: 50 g (according to EN 60068-2-27) Maximum operating speed: 10,000 /min (without shaft seal) 6,000 /min (with shaft seal) Operating torque: 0.3 Ncm Pe
Specification: Part Number 1038855 Moment of inertia of the rotor: 54 gcm² Repeat accuracy: 0.005 ° Max. number of steps per revolution: 452 Measuring step deviation: 0.005 °, 0.016 ° Initialization time: 80 ms Bearing lifetime: 3.6 x 10^9 revolutions Resistance to shocks: 50 g (according to EN 60068-2-27) Operation of zero-set: ≥ 100 ms Maximum operating speed: 10,000 /min (without shaft seal) 6
Specification: Part Number 1036609 Operating power consumption (no load): 90 mA Maximum operating speed: 10,000 /min (without shaft seal) 6,000 /min (with shaft seal) Working temperature range: -20 °C ... 85 °C Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Moment of inertia of the rotor: 54 gcm² Electrical interface: Connector M23, 21-pin, radial EMC: According to EN
Specification: Part Number 1209174 Bearing lifetime: 3.6 x 10^9 revolutions Enclosure rating: IP 65, according to IEC 60529, with mating connector fitted Operating torque: 0.3 Ncm Max. number of revolutions: 1 Initialization time: 80 ms Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Max. angular acceleration: 500,000 rad/s² Resistance to shocks: 50 g (according to
Specification: Part Number 1032760 EMC: According to EN 61000-6-2 and EN 61000-6-3 Maximum operating speed: 10,000 /min (without shaft seal) 6,000 /min (with shaft seal) Mass: 0.3 kg Repeat accuracy: 0.005 ° Resolution power: 2,048 x 1 Max. angular acceleration: 500,000 rad/s² Bearing lifetime: 3.6 x 10^9 revolutions Measuring step deviation: 0.005 °, 0.016 ° Operating torque: 0.3 Ncm Shaft diamet
Specification: Part Number 1031740 Electrical interface: Connector M23, 21-pin, radial Maximum operating speed: 10,000 /min (without shaft seal) 6,000 /min (with shaft seal) Error limits: 0.035 ° (binary number of steps) 0.046 ° (non-binary number of steps) Repeat accuracy: 0.005 ° Mechanical interface: Solid shaft, Face mount flange Initialization time: 80 ms Moment of inertia of the rotor: 54 gcm² Stora
Specification: Part Number 1030139 Maximum operating speed: 10,000 /min (without shaft seal) 6,000 /min (with shaft seal) Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Start up torque: 0.4 Ncm Mechanical interface: Solid shaft, Face mount flange Max. angular acceleration: 500,000 rad/s² Measuring step deviation: 0.005 °, 0.016 ° Repeat accuracy: 0.005 ° Mass: 0.3 kg Perm
Specification: Part Number 1034742 Measuring step: 360 ° /number of lines Operation of zero-set: ≥ 100 ms Moment of inertia of the rotor: 54 gcm² Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Mass: 0.3 kg Max. number of revolutions: 1 Resistance to shocks: 50 g (according to EN 60068-2-27) Error limits: 0.035 ° (binary number of steps) 0.046 ° (non-binary numb
Specification: Part Number 1035074 Repeat accuracy: 0.005 ° Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) EMC: According to EN 61000-6-2 and EN 61000-6-3 Mechanical interface: Solid shaft, Face mount flange Measuring step deviation: 0.005 °, 0.016 ° Operation of zero-set: ≥ 100 ms Bearing lifetime: 3.6 x 10^9 revolutions Operating torque: 0.3 Ncm Max. number of revolu
Specification: Part Number 1035299 Mechanical interface: Solid shaft, Face mount flange Shaft diameter: 10 mm Electrical interface: Connector M23, 21-pin, axial Mass: 0.3 kg Resistance to shocks: 50 g (according to EN 60068-2-27) Maximum operating speed: 10,000 /min (without shaft seal) 6,000 /min (with shaft seal) EMC: According to EN 61000-6-2 and EN 61000-6-3 Max. number of steps per revolution: 720 Op
Specification: Part Number 1034436 Start up torque: 0.4 Ncm Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Mass: 0.3 kg Resistance to shocks: 50 g (according to EN 60068-2-27) Measuring step: 360 ° /number of lines Max. number of steps per revolution: 1,440 Repeat accuracy: 0.005 ° Operating power consumption (no load): 90 mA Operation of zero-set: ≥ 100 ms
Specification: Part Number 1035798 Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Operating voltage range: 10 V DC ... 32 V DC Initialization time: 80 ms Moment of inertia of the rotor: 54 gcm² Storage temperature range: -40 °C ... 100 °C Measuring step: 360 ° /number of lines Measuring step deviation: 0.005 °, 0.016 ° Error limits: 0.035 ° (binary number of steps) 0.046
Specification: Part Number 1035278 Storage temperature range: -40 °C ... 100 °C Moment of inertia of the rotor: 54 gcm² Max. number of revolutions: 1 Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Initialization time: 80 ms Mechanical interface: Solid shaft, Face mount flange Measuring step deviation: 0.005 °, 0.016 ° Error limits: 0.035 ° (binary number of steps) 0.046 °
Specification: Part Number 1036743 Mechanical interface: Solid shaft, Face mount flange Resolution power: 14,400 x 1 Resistance to shocks: 50 g (according to EN 60068-2-27) Measuring step: 360 ° /number of lines Shaft diameter: 10 mm Moment of inertia of the rotor: 54 gcm² Measuring step deviation: 0.005 °, 0.016 ° Storage temperature range: -40 °C ... 100 °C Permissible Load capacity of shaft: 20 N
Specification: Part Number 1032811 Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Initialization time: 80 ms Electrical interface: Cable, 22-pin, radial, 1.5 m Measuring step deviation: 0.005 °, 0.016 ° Start up torque: 0.4 Ncm Storage temperature range: -40 °C ... 100 °C Error limits: 0.035 ° (binary number of steps) 0.046 ° (non-binary number of steps) Resistan
Specification: Part Number 1035359 Repeat accuracy: 0.005 ° Moment of inertia of the rotor: 54 gcm² Maximum operating speed: 10,000 /min (without shaft seal) 6,000 /min (with shaft seal) Storage temperature range: -40 °C ... 100 °C Operating voltage range: 10 V DC ... 32 V DC Error limits: 0.035 ° (binary number of steps) 0.046 ° (non-binary number of steps) Resistance to shocks: 50 g (according to EN 60068
Specification: Part Number 1034703 Enclosure rating: IP 66, according to IEC 60529 Operating torque: 0.3 Ncm Start up torque: 0.4 Ncm Moment of inertia of the rotor: 54 gcm² Operating voltage range: 10 V DC ... 32 V DC Operating power consumption (no load): 90 mA Working temperature range: -20 °C ... 85 °C Bearing lifetime: 3.6 x 10^9 revolutions Operation of zero-set: ≥ 100 ms Measuring step:
Menu
Mail Us
enquiry@onstocktrading.com