Specification: Part Number 6051854 Output signal: 2 x PNP + 4 mA ... 20 mA Non-linearity: ≤ ± 0.5 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) Maximum ohmic load RA: ≤ 0.5 k&;937; Connection type: Round connector M12 x 1, 5-pin Overpressure safety: 2-fold Temperature coefficient in rated temperature range: Typical TC of zero: In the temperature range 0 °C ... 20 °C: 0.7 % of span / 10 K
Specification: Part Number 6051841 Internal transmission fluid: Medical white oil, FDA compliant according to CFR 172.878 and 21 CFR 178.3620(a), compliant to USP, EP, and JP Protection class III: + Relative humidity: 45 % ... 75 % Maximum ohmic load RA: ≤ 0.5 k&;937; Measuring range: 0 bar ... 1.6 bar Total current consumption: Max. 320 mA (incl. switching current) Overpressure safety: 2-fold Shock load: 5
Specification: Part Number 6051860 Measuring range: 0 bar ... 1.6 bar Rotatable housing: Display against housing with electrical connection: 330 °, Housing against process connection: 320 ° Zero point adjustment: Max. + 3 % of span Pressure type: Gauge pressure Rated temperature range: 0 °C ... +80 °C Internal transmission fluid: Medical white oil, FDA compliant according to CFR 172.878 and 21 CFR 178.3620(a), com
Specification: Part Number 6051878 Power consumption: Max. 70 mA Total current consumption: Max. 170 mA (incl. switching current) Rated temperature range: 0 °C ... +80 °C Process temperature: -20 °C ... +125 °C, +150 °C for max. 1 h CE-conformity: EMC directive: 2004/108/EC, EN 61326-2-3 Accuracy: ≤ ± 1 % of span (Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of m
Specification: Part Number 6051829 Internal transmission fluid: Medical white oil, FDA compliant according to CFR 172.878 and 21 CFR 178.3620(a), compliant to USP, EP, and JP Setting accuracy of switching outputs: ≤ ± 0.5 % of span Ambient temperature: -20 °C ... +80 °C Output signal: 1 x PNP + 4 mA ... 20 mA Non-linearity: ≤ ± 0.5 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) Gauge pres
Specification: Part Number 6051848 Isolation voltage: 500 V DC Ambient temperature: -20 °C ... +80 °C Storage temperature: -20 °C ... +80 °C Overpressure safety: 2-fold Compound pressure: -1 bar ... 0 bar up to -1 bar ... +24 bar Relative humidity: 45 % ... 75 % EHEDG approval: + Measuring range: 0 bar ... 1.6 bar Process connection: Tri-Clamp 1 ½'' Internal transmission fluid: Medical white oil,
Specification: Part Number 6051836 Power consumption: Max. 70 mA EHEDG approval: + Long-term drift/one-year stability: ≤ ± 0.2 % of span according to IEC 61298-2 Zero point adjustment: Max. + 3 % of span Internal transmission fluid: Medical white oil, FDA compliant according to CFR 172.878 and 21 CFR 178.3620(a), compliant to USP, EP, and JP Maximum ohmic load RA: ≤ 0.5 k&;937; Ambient temperature: -20 °C
Specification: Part Number 6051855 Total current consumption: Max. 570 mA (incl. switching current) Vibration load: 10 g according to IEC 60068-2-6 (vibration under resonance) Output signal: 2 x PNP + 4 mA ... 20 mA Process connection: Conical coupling (DIN 11851) DN 40 with union nut Relative humidity: 45 % ... 75 % Measuring range: 0 bar ... 2.5 bar Response time: 3 ms Overpressure safety: 2-fold Zero poi
Specification: Part Number 6051873 Power consumption: Max. 70 mA Absolute pressure: 0 bar ... 1 bar up to 0 bar ... 25 bar Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M, Protection class: III, Overvoltage protection: 40 V DC, Reverse polarity protection: L+ towards M Compound pressure: -1 bar ... 0 bar up to -1 bar ... +24 bar Temperature coefficient in rated temperature range: Typical TC of zero: In t
Specification: Part Number 6051861 Power consumption: Max. 70 mA Overpressure safety: 2-fold Enclosure rating: IP 65 / IP 67 Non-linearity: ≤ ± 0.5 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) Medium: Liquid and gaseous media Wetted parts: Stainless steel 1.4435 / 316L Connection type: Round connector M12 x 1, 5-pin Storage temperature: -20 °C ... +80 °C Long-term drift/one-year
Specification: Part Number 6051879 Internal transmission fluid: Medical white oil, FDA compliant according to CFR 172.878 and 21 CFR 178.3620(a), compliant to USP, EP, and JP Non-linearity: ≤ ± 0.5 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) Gauge pressure: 0 bar ... 1 bar up to 0 bar ... 25 bar Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M, Protection class: III, Overvoltage pr
Specification: Part Number 6051830 Seal: Without seal Response time: 3 ms Shock load: 50 g according to IEC 60068-2-27 (mechanical shock) Setting accuracy of switching outputs: ≤ ± 0.5 % of span Non-linearity: ≤ ± 0.5 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) Absolute pressure: 0 bar ... 1 bar up to 0 bar ... 25 bar Output signal: 1 x PNP + 4 mA ... 20 mA Total current consumpt
Specification: Part Number 6051849 Shock load: 50 g according to IEC 60068-2-27 (mechanical shock) Medium: Liquid and gaseous media Setting accuracy of switching outputs: ≤ ± 0.5 % of span Temperature coefficient in rated temperature range: Typical TC of zero: In the temperature range 0 °C ... 20 °C: 0.7 % of span / 10 K. In the temperature range 20 °C … 80 °C: 0.2 % of span / 10 K. typical TC of span: In the temper
Specification: Part Number 6051867 Seal: Without seal Zero point adjustment: Max. + 3 % of span Response time: 3 ms Absolute pressure: 0 bar ... 1 bar up to 0 bar ... 25 bar Rated temperature range: 0 °C ... +80 °C Ambient temperature: -20 °C ... +80 °C Non-linearity: ≤ ± 0.5 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) Display: 14-segment-LED, blue, 4-digits, height 9 mm, electr
Specification: Part Number 6051856 Display: 14-segment-LED, blue, 4-digits, height 9 mm, electronically turnable by 180°, Update: 1,000, 500, 200, 100 ms (adjustable), Accuracy: ≤ 1 % of span ± 1 digit Ambient temperature: -20 °C ... +80 °C Output signal: 2 x PNP + 4 mA ... 20 mA EHEDG approval: + Vibration load: 10 g according to IEC 60068-2-6 (vibration under resonance) Rotatable housing: Display against hou
Specification: Part Number 6051874 Overpressure safety: 2-fold Temperature coefficient in rated temperature range: Typical TC of zero: In the temperature range 0 °C ... 20 °C: 0.7 % of span / 10 K. In the temperature range 20 °C … 80 °C: 0.2 % of span / 10 K. typical TC of span: In the temperature range 0 °C … 80 °C: 0.1 % of the span / 10 K Accuracy: ≤ ± 1 % of span (Including non-linearity, hysteresis, zero point
Specification: Part Number 6051843 Setting accuracy of switching outputs: ≤ ± 0.5 % of span Non-linearity: ≤ ± 0.5 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) Connection type: Round connector M12 x 1, 4-pin Vibration load: 10 g according to IEC 60068-2-6 (vibration under resonance) Maximum ohmic load RA: ≤ 0.5 k&;937; Ambient temperature: -20 °C ... +80 °C Total current consumpt
Specification: Part Number 6051880 Shock load: 50 g according to IEC 60068-2-27 (mechanical shock) Isolation voltage: 500 V DC Long-term drift/one-year stability: ≤ ± 0.2 % of span according to IEC 61298-2 Display: 14-segment-LED, blue, 4-digits, height 9 mm, electronically turnable by 180°, Update: 1,000, 500, 200, 100 ms (adjustable), Accuracy: ≤ 1 % of span ± 1 digit Process temperature: -20 °C ... +125 °C,
Specification: Part Number 6051831 Storage temperature: -20 °C ... +80 °C Absolute pressure: 0 bar ... 1 bar up to 0 bar ... 25 bar Rotatable housing: Display against housing with electrical connection: 330 °, Housing against process connection: 320 ° Power consumption: Max. 70 mA Enclosure rating: IP 65 / IP 67 Total current consumption: Max. 320 mA (incl. switching current) Maximum ohmic load RA: ≤ 0.5 k&
Specification: Part Number 6051850 EHEDG approval: + Response time: 3 ms Measuring range: 0 bar ... 6 bar Process temperature: -20 °C ... +100 °C, +135 °C for max. 1 h Absolute pressure: 0 bar ... 1 bar up to 0 bar ... 25 bar Rated temperature range: 0 °C ... +80 °C Accuracy: ≤ ± 1 % of span (Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement accordi
Specification: Part Number 6051868 Pressure type: Gauge pressure Rated temperature range: 0 °C ... +80 °C Setting accuracy of switching outputs: ≤ ± 0.5 % of span Temperature coefficient in rated temperature range: Typical TC of zero: In the temperature range 0 °C ... 20 °C: 0.7 % of span / 10 K. In the temperature range 20 °C … 80 °C: 0.2 % of span / 10 K. typical TC of span: In the temperature range 0 °C … 80