Specification: Part Number 6051862 Long-term drift/one-year stability: ≤ ± 0.2 % of span according to IEC 61298-2 Medium: Liquid and gaseous media CE-conformity: EMC directive: 2004/108/EC, EN 61326-2-3 Overpressure safety: 2-fold Wetted parts: Stainless steel 1.4435 / 316L Display: 14-segment-LED, blue, 4-digits, height 9 mm, electronically turnable by 180°, Update: 1,000, 500, 200, 100 ms (adjustable), Accuracy: ≤ 1 % of span ± 1 digit Measuring range: 0 bar ... 6 bar Zero point adjustment: Max. + 3 % of span Housing material: Display window: PC, Plastic head: PC + ABS, Buttons: TPE-E, Lower body: stainless steel 304 Storage temperature: -20 °C ... +80 °C Vibration load: 10 g according to IEC 60068-2-6 (vibration under resonance) Shock load: 50 g according to IEC 60068-2-27 (mechanical shock) Rotatable housing: Display against housing with electrical connection: 330 °, Housing against process connection: 320 ° Process temperature: -20 °C ... +125 °C, +150 °C for max. 1 h Total current consumption: Max. 570 mA (incl. switching current) Isolation voltage: 500 V DC Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M, Protection class: III, Overvoltage protection: 40 V DC, Reverse polarity protection: L+ towards M Output signal: 2 x PNP + 4 mA ... 20 mA Power consumption: Max. 70 mA Seal: Wetted parts: EPDM, Not wetted parts: EPDM Accuracy: ≤ ± 1 % of span (Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement according to IEC 61298-2)) Non-linearity: ≤ ± 0.5 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) Internal transmission fluid: Medical white oil, FDA compliant according to CFR 172.878 and 21 CFR 178.3620(a), compliant to USP, EP, and JP Absolute pressure: 0 bar ... 1 bar up to 0 bar ... 25 bar Rated temperature range: 0 °C ... +80 °C Gauge pressure: 0 bar ... 1 bar up to 0 bar ... 25 bar Maximum ohmic load RA: ≤ 0.5 k&;937; Response time: 3 ms Pressure type: Gauge pressure Relative humidity: 45 % ... 75 % Connection type: Round connector M12 x 1, 5-pin Ambient temperature: -20 °C ... +80 °C Temperature coefficient in rated temperature range: Typical TC of zero: In the temperature range 0 °C ... 20 °C: 0.7 % of span / 10 K. In the temperature range 20 °C … 80 °C: 0.2 % of span / 10 K. typical TC of span: In the temperature range 0 °C … 80 °C: 0.1 % of the span / 10 K Compound pressure: -1 bar ... 0 bar up to -1 bar ... +24 bar Process connection: G 1 hygienic flush-mounted Enclosure rating: IP 65 / IP 67 Protection class III: + Setting accuracy of switching outputs: ≤ ± 0.5 % of span