SICK - Fluid sensors

Image
Part Number
Description
Specification: Part Number 1062966 Setting accuracy of switching outputs: ≤ ± 0.2 % of span Accuracy: ≤ ± 1.5 % of span (Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement according to IEC 61298-2)), ≤ ± 2 % of span incl. temperature error (Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement according to IEC 61298-
Specification: Part Number 1062967 Vibration load: Max. 5 g (10 ... 150 Hz), xyz, according to DIN EN 60068-2-6 Non-linearity: ≤ ± 0.5 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) Medium: Dry compressed air Non-repeatability: ≤ ± 0.2 % of span Power consumption: Max. 40 mA at L+ = 24 VDC Protection class III: + Rated temperature range: +10 °C ... +60 °C Process connection: PIF
Specification: Part Number 1062958 Shock load: Max. 30 g, xyz according to IEC 60068-2-27 (11 ms, mechanical shock) Setting accuracy of switching outputs: ≤ ± 0.2 % of span Medium: Dry compressed air Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M and L+, Protection class: III, Overvoltage protection: 32 V DC, Reverse polarity protection: L+ towards M Pressure type: Gauge pressure Relative humidit
Specification: Part Number 1062959 Storage temperature: -20 °C ... +80 °C Gauge pressure: -1 bar ... 0 bar; -1 bar ... +1 bar; 0 bar ... +6 bar; 0 bar ... +10 bar Rated temperature range: +10 °C ... +60 °C Ambient temperature: 0 °C ... +60 °C CRUus certificate: + Zero point adjustment: Max. + 5 % of span Non-repeatability: ≤ ± 0.2 % of span RoHS certificate: + Setting accuracy of switching outputs
Specification: Part Number 1062960 Ambient temperature: 0 °C ... +60 °C Display: Update: 1,000, 500, 200, 100 ms (adjustable), Pressure display: 4 digits, 16 segments, Pressure unit in display can be switched: bar, MPa, kPa, psi and inHg, LCD with LED backlight (green/red), can be rotated electronically by 180° Analog signal output and ohmic load RA: Load resistance for voltage output > 3 kOhm, Load resistance for current outp
Specification: Part Number 1062961 Ambient temperature: 0 °C ... +60 °C Relative humidity: ≤ 90 % Protection class III: + Zero point adjustment: Max. + 5 % of span CE-conformity: EMC directive: 2004/108/EC, EN 61326-2-3 Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M and L+, Protection class: III, Overvoltage protection: 32 V DC, Reverse polarity protection: L+ towards M Enclosure rating: IP
Specification: Part Number 1062977 Display: Update: 1,000, 500, 200, 100 ms (adjustable), Pressure display: 4 digits, 16 segments, Pressure unit in display can be switched: bar, MPa, kPa, psi and inHg, LCD with LED backlight (green/red), can be rotated electronically by 180° Relative humidity: ≤ 90 % Non-repeatability: ≤ ± 0.2 % of span Medium: Dry compressed air Gauge pressure: -1 bar ... 0 bar; -1 bar ... +1 bar
Specification: Part Number 1062978 Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M and L+, Protection class: III, Overvoltage protection: 32 V DC, Reverse polarity protection: L+ towards M Weight sensor: Ca. 40 g Housing material: Seals: NBR, Housing: polycarbonate, DIN rail mounting: POM, Buttons: TPE Relative humidity: ≤ 90 % CULus certificate: - Non-linearity: ≤ ± 0.5 % (of span (Best Fit S
Specification: Part Number 1062979 Analog signal output and ohmic load RA: Load resistance for voltage output > 3 kOhm, Load resistance for current output < 600 Ohm, Optional, 4 mA ... 20 mA / 0 V… 10 V. Automatic detection depending on connected load or programmable. Output signals can be inverted: 20 mA … 4 mA / 10 V … 0 V Enclosure rating: IP 65 / IP 67 According to IEC 60529 Output signal: 2 x PNP/NPN/Push-Pull + 4 mA
Specification: Part Number 1062970 CRUus certificate: + Ambient temperature: 0 °C ... +60 °C Accuracy: &le; ± 1.5 % of span (Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement according to IEC 61298-2)), &le; ± 2 % of span incl. temperature error (Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement according to IEC 612
Specification: Part Number 1062971 Non-repeatability: &le; ± 0.2 % of span Setting accuracy of switching outputs: &le; ± 0.2 % of span CE-conformity: EMC directive: 2004/108/EC, EN 61326-2-3 Accuracy: &le; ± 1.5 % of span (Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement according to IEC 61298-2)), &le; ± 2 % of span incl. temperature error (Including non-linearity,
Specification: Part Number 1062991 Diagnostics output: Switching output 2 can be set as diagnostics output Power consumption: Max. 40 mA at L+ = 24 VDC Storage temperature: -20 °C ... +80 °C Output signal: 2 x PNP/NPN/Push-Pull + 4 mA ... 20 mA / 0 V … 10 V Shock load: Max. 30 g, xyz according to IEC 60068-2-27 (11 ms, mechanical shock) Zero point adjustment: Max. + 5 % of span Electrical safety: Short-circuit
Specification: Part Number 1062992 Analog signal output and ohmic load RA: Load resistance for voltage output > 3 kOhm, Load resistance for current output < 600 Ohm, Optional, 4 mA ... 20 mA / 0 V… 10 V. Automatic detection depending on connected load or programmable. Output signals can be inverted: 20 mA … 4 mA / 10 V … 0 V Zero point adjustment: Max. + 5 % of span Protection class III: + Non-linearity: &le; ± 0.5 %
Specification: Part Number 1062983 Analog signal output and ohmic load RA: Load resistance for voltage output > 3 kOhm, Load resistance for current output < 600 Ohm, Optional, 4 mA ... 20 mA / 0 V… 10 V. Automatic detection depending on connected load or programmable. Output signals can be inverted: 20 mA … 4 mA / 10 V … 0 V Weight sensor: Ca. 40 g Gauge pressure: -1 bar ... 0 bar; -1 bar ... +1 bar; 0 bar ... +6 bar; 0 ba
Specification: Part Number 1062984 Initialization time: 300 ms Display: Update: 1,000, 500, 200, 100 ms (adjustable), Pressure display: 4 digits, 16 segments, Pressure unit in display can be switched: bar, MPa, kPa, psi and inHg, LCD with LED backlight (green/red), can be rotated electronically by 180° Process temperature: 0 °C ... +60 °C Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M and L+, Protection
Specification: Part Number 1062985 CULus certificate: - Initialization time: 300 ms Ambient temperature: 0 °C ... +60 °C RoHS certificate: + Medium: Dry compressed air Power consumption: Max. 40 mA at L+ = 24 VDC Display: Update: 1,000, 500, 200, 100 ms (adjustable), Pressure display: 4 digits, 16 segments, Pressure unit in display can be switched: bar, MPa, kPa, psi and inHg, LCD with LED backlight (green/red),
Specification: Part Number 6043792 Pressure type: Absolute pressure Weight sensor: Ca. 200 g Compound pressure: -1 bar ... 0 bar up to -1 bar ... +24 bar Shock load: 50 g according to IEC 60068-2-27 (mechanical shock) Power consumption: 45 mA (for configurations without analog output signal), 70 mA (for configurations with analog output signal) Vibration load: 10 g according to IEC 60068-2-6 (vibration under resonance
Specification: Part Number 6043465 Weight sensor: Ca. 200 g Output signal: 2 x PNP Storage temperature: -20 °C ... +80 °C Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M, Protection class: III, Overvoltage protection: 40 V DC, Reverse polarity protection: L+ towards M Service life: Minimum 100 Mio. life cycles Wetted parts: Pressure connection: stainless steel 316L, Pressure sensor: stainless steel
Specification: Part Number 6050283 CE-conformity: Pressure equipment directive: This instrument is a pressure accessory as defined by the directive 97/23/EC, EMC directive: 2004/108/EC, EN 61326-2-3 Isolation voltage: 500 V DC Temperature coefficient in rated temperature range: Mean TC of span &le; 0.2 % of span / 10 K, Mean TC of zero: &le; 0.2% of span / 10 K Vibration load: 10 g according to IEC 60068-2-6 (vibration under
Specification: Part Number 6039775 Response time: 3 ms Internal transmission fluid: Silicone oil (only with pressure ranges < 0 bar ... 10 bar and &le; 0 bar abs ... 25 bar abs) Ambient temperature: -20 °C ... +80 °C Weight sensor: Ca. 200 g Medium: Liquid and gaseous media Compound pressure: -1 bar ... 0 bar up to -1 bar ... +24 bar Power consumption: 45 mA (for configurations without analog output signal), 70
Specification: Part Number 6038930 Process connection: G ½ B according to EN 837 Gauge pressure: 0 bar ... 1 bar up to bar ... 600 bar Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M, Protection class: III, Overvoltage protection: 40 V DC, Reverse polarity protection: L+ towards M Process temperature: -20 °C ... +85 °C Vibration load: 10 g according to IEC 60068-2-6 (vibration under resonance) Mea
Specification: Part Number 6041233 Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M, Protection class: III, Overvoltage protection: 40 V DC, Reverse polarity protection: L+ towards M Internal transmission fluid: Silicone oil (only with pressure ranges < 0 bar ... 10 bar and &le; 0 bar abs ... 25 bar abs) Enclosure rating: IP 67 Compound pressure: -1 bar ... 0 bar up to -1 bar ... +24 bar Long-term drift/o
Specification: Part Number 6038870 Weight sensor: Ca. 200 g Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M, Protection class: III, Overvoltage protection: 40 V DC, Reverse polarity protection: L+ towards M Power consumption: 45 mA (for configurations without analog output signal), 70 mA (for configurations with analog output signal) Accuracy: &le; ± 1 % of span, (Including non-linearity, hysteresis, zero p
Specification: Part Number 6038896 Seal: NBR Storage temperature: -20 °C ... +80 °C Output signal: 1 x PNP + 4 mA ... 20 mA Enclosure rating: IP 67 Shock load: 50 g according to IEC 60068-2-27 (mechanical shock) Display: 14-segment-LED, blue, 4-digits, height 9 mm, electronically turnable by 180°, Update: 1,000, 500, 200, 100 ms (adjustable), Accuracy: &le; 1 % of span ± 1 digit Total current consumption: Max.
Specification: Part Number 6041541 Service life: Minimum 100 Mio. life cycles Zero point adjustment: Max. + 3 % of span Shock load: 50 g according to IEC 60068-2-27 (mechanical shock) Pressure type: Compound pressure Total current consumption: Max. 350 mA / 570 mA (incl. switching current) Non-linearity: &le; ± 0.5 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) Connection type: Round connecto
Specification: Part Number 6041614 Compound pressure: -1 bar ... 0 bar up to -1 bar ... +24 bar Protection class III: + Gauge pressure: 0 bar ... 1 bar up to bar ... 600 bar Zero point adjustment: Max. + 3 % of span Measuring range: -1 bar ... 9 bar Isolation voltage: 500 V DC Enclosure rating: IP 67 Storage temperature: -20 °C ... +80 °C Rated temperature range: 0 °C ... +80 °C Weight sensor: Ca.
Specification: Part Number 6049699 Rated temperature range: 0 °C ... +80 °C Long-term drift/one-year stability: &le; 0.2 % of span according to IEC 61298-2 Enclosure rating: IP 67 Weight sensor: Ca. 200 g Process temperature: -20 °C ... +85 °C Pressure type: Compound pressure Internal transmission fluid: Silicone oil (only with pressure ranges < 0 bar ... 10 bar and &le; 0 bar abs ... 25 bar abs) Zero poin
Specification: Part Number 6038871 Long-term drift/one-year stability: &le; 0.2 % of span according to IEC 61298-2 Temperature coefficient in rated temperature range: Mean TC of span &le; 0.2 % of span / 10 K, Mean TC of zero: &le; 0.2% of span / 10 K Output signal: 2 x PNP Process temperature: -20 °C ... +85 °C Measuring range: -1 bar ... 24 bar Setting accuracy of switching outputs: &le; ± 0.5 % of span Servic
Specification: Part Number 6038897 Power consumption: 45 mA (for configurations without analog output signal), 70 mA (for configurations with analog output signal) Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M, Protection class: III, Overvoltage protection: 40 V DC, Reverse polarity protection: L+ towards M Process temperature: -20 °C ... +85 °C Connection type: Round connector M12 x 1, 4-pin, IP 67 R
Specification: Part Number 6038911 Temperature coefficient in rated temperature range: Mean TC of span &le; 0.2 % of span / 10 K, Mean TC of zero: &le; 0.2% of span / 10 K Weight sensor: Ca. 200 g Gauge pressure: 0 bar ... 1 bar up to bar ... 600 bar Measuring range: -1 bar ... 24 bar Non-linearity: &le; ± 0.5 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2) Display: 14-segment-LED, blue, 4-digits
Menu
Mail Us
enquiry@onstocktrading.com